]> CyberLeo.Net >> Repos - FreeBSD/stable/10.git/blob - bin/chio/chio.1
Copy head (r256279) to stable/10 as part of the 10.0-RELEASE cycle.
[FreeBSD/stable/10.git] / bin / chio / chio.1
1 .\"     $NetBSD: chio.1,v 1.4 1997/10/02 00:41:25 hubertf Exp $
2 .\"-
3 .\" Copyright (c) 1996 Jason R. Thorpe <thorpej@and.com>
4 .\" All rights reserved.
5 .\"
6 .\" Redistribution and use in source and binary forms, with or without
7 .\" modification, are permitted provided that the following conditions
8 .\" are met:
9 .\" 1. Redistributions of source code must retain the above copyright
10 .\"    notice, this list of conditions and the following disclaimer.
11 .\" 2. Redistributions in binary form must reproduce the above copyright
12 .\"    notice, this list of conditions and the following disclaimer in the
13 .\"    documentation and/or other materials provided with the distribution.
14 .\" 3. All advertising materials mentioning features or use of this software
15 .\"    must display the following acknowledgements:
16 .\"     This product includes software developed by Jason R. Thorpe
17 .\"     for And Communications, http://www.and.com/
18 .\" 4. The name of the author may not be used to endorse or promote products
19 .\"    derived from this software without specific prior written permission.
20 .\"
21 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
22 .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
23 .\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
24 .\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
25 .\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
26 .\" BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
27 .\" LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
28 .\" AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
29 .\" OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
30 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
31 .\" SUCH DAMAGE.
32 .\"
33 .\" $FreeBSD$
34 .\"
35 .Dd May 14, 1998
36 .Dt CHIO 1
37 .Os
38 .Sh NAME
39 .Nm chio
40 .Nd medium changer control utility
41 .Sh SYNOPSIS
42 .Nm
43 .Op Fl f Ar changer
44 .Ar command
45 .Op Fl <flags>
46 .Ar arg1
47 .Ar arg2
48 .Op Ar arg3 Op ...
49 .Sh DESCRIPTION
50 The
51 .Nm
52 utility is used to control the operation of medium changers, such as those
53 found in tape and optical disk jukeboxes.
54 .Pp
55 The options are as follows:
56 .Bl -tag -width indent
57 .It Fl f Ar changer
58 Use the device
59 .Ar changer
60 rather than the default device
61 .Pa /dev/ch0 .
62 .El
63 .Pp
64 The default changer may be overridden by setting the environment variable
65 .Ev CHANGER
66 to the desired changer device.
67 .Pp
68 A medium changer apparatus is made up of
69 .Em elements .
70 There are five element types:
71 .Em picker
72 (medium transport),
73 .Em slot
74 (storage),
75 .Em portal
76 (import/export),
77 .Em drive
78 (data transfer), and
79 .Em voltag
80 (select by volume identifier).
81 The
82 .Em voltag
83 pseudo-element type allows the selection of tapes by their volume tag
84 (typically a barcode on the tape).
85 .Pp
86 In this command description, the shorthand
87 .Em ET
88 will be used to represent an element type, and
89 .Em EU
90 will be used to represent an element unit.
91 For example, to represent the first robotic arm in the changer, the
92 .Em ET
93 would be
94 .Dq picker
95 and the
96 .Em EU
97 would be
98 .Dq 0 .
99 .Sh SUPPORTED COMMANDS
100 .Bl -tag -width indent
101 .It Ic move Xo
102 .Ar <from ET> <from EU> <to ET> <to EU>
103 .Op Cm inv
104 .Xc
105 Move the media unit from
106 .Ar <from ET/EU>
107 to
108 .Ar <to ET/EU> .
109 If the optional modifier
110 .Cm inv
111 is specified, the media unit will be inverted before insertion.
112 .It Ic exchange Xo
113 .Ar <src ET> <src EU> <dst1 ET> <dst1 EU>
114 .Op Ar <dst2 ET> <dst2 ET>
115 .Op Cm inv1
116 .Op Cm inv2
117 .Xc
118 Perform a media unit exchange operation.
119 The media unit in
120 .Ar <src ET/EU>
121 is moved to
122 .Ar <dst1 ET/EU>
123 and the media unit previously in
124 .Ar <dst1 ET/EU>
125 is moved to
126 .Ar <dst2 ET/EU> .
127 In the case of a simple exchange,
128 .Ar <dst2 ET/EU>
129 is omitted and the values
130 .Ar <src ET/EU>
131 are used in their place.
132 The optional modifiers
133 .Cm inv1
134 and
135 .Cm inv2
136 specify whether the media units are to be inverted before insertion into
137 .Ar <dst1 ET/EU>
138 and
139 .Ar <dst2 ET/EU>
140 respectively.
141 .Pp
142 Note that not all medium changers support the
143 .Ic exchange
144 operation; the changer must have multiple free pickers or emulate
145 multiple free pickers with transient storage.
146 .It Ic return Xo
147 .Ar <from ET> <from EU>
148 .Xc
149 Return the media unit to its source element.
150 This command will query the status of the specified media unit, and
151 will move it to the element specified in its source attribute.
152 This is a convenient way to return media from a drive or portal
153 to its previous element in the changer.
154 .Pp
155 .It Ic position Xo
156 .Ar <to ET> <to EU>
157 .Op Cm inv
158 .Xc
159 Position the picker in front of the element described by
160 .Ar <to ET/EU> .
161 If the optional modifier
162 .Cm inv
163 is specified, the media unit will be inverted before insertion.
164 .Pp
165 Note that not all changers behave as expected when issued this command.
166 .It Ic params
167 Report the number of slots, drives, pickers, and portals in the changer,
168 and which picker unit the changer is currently configured to use.
169 .It Ic getpicker
170 Report which picker unit the changer is currently configured to use.
171 .It Ic setpicker Xo
172 .Ar <unit>
173 .Xc
174 Configure the changer to use picker
175 .Ar <unit> .
176 .Pp
177 .It Ic ielem Xo
178 .Op Ar <timeout>
179 .Xc
180 Perform an
181 .Em INITIALIZE ELEMENT STATUS
182 operation on the changer.
183 The optional
184 .Ar <timeout>
185 parameter may be given to specify a timeout in seconds for the
186 operations.
187 This may be used if the operation takes unusually long
188 because of buggy firmware or the like.
189 .It Ic voltag Xo
190 .Op Fl fca
191 .Ar <ET>
192 .Ar <EU>
193 .Op Ar <label>
194 .Op Ar <serial>
195 .Xc
196 Change volume tag for an element in the media changer.
197 This command
198 is only supported by few media changers.
199 If it is not supported by a
200 device, using this command will usually result in an "Invalid Field in
201 CDB" error message on the console.
202 .Pp
203 If the
204 .Fl c
205 flag is specified, the volume tag of the specified element is
206 cleared.
207 If the
208 .Fl f
209 flag is specified, the volume tag is superseded with the specified
210 volume tag even if a volume tag is already defined for the element.
211 It is an error to not specify the
212 .Fl f
213 flag when trying to set a label for an element which already has
214 volume tag information defined.
215 .Pp
216 The command works with the primary volume tag or, if the
217 .Fl a
218 flag is given, with the alternate volume tag.
219 .It Ic status Xo
220 .Op Fl vVsSbIa
221 .Op Ar <type>
222 .Xc
223 Report the status of all elements in the changer.
224 If
225 .Ar <type>
226 is specified, report the status of all elements of type
227 .Ar <type> .
228 .It Fl v
229 Print the primary volume tag for each loaded medium, if any.
230 The volume
231 tag is printed as
232 .Dq <LABEL:SERIAL> .
233 .It Fl V
234 Print the alternate volume tag for each loaded medium, if any.
235 .It Fl s
236 Print the additional sense code and additional sense code qualifier for
237 each element.
238 .It Fl S
239 Print the element source address for each element.
240 .It Fl b
241 Print SCSI bus information for each element.
242 Note that this information
243 is valid only for drives.
244 .It Fl I
245 Print the internal element addresses for each element.
246 The internal
247 element address is not normally used with this driver.
248 It is reported
249 for diagnostic purposes only.
250 .It Fl a
251 Print all additional information (as in
252 .Fl vVsSba ) .
253 .El
254 .Pp
255 The status bits are defined as follows:
256 .Bl -tag -width indent
257 .It FULL
258 Element contains a media unit.
259 .It IMPEXP
260 Media was deposited into element by an outside human operator.
261 .It EXCEPT
262 Element is in an abnormal state.
263 .It ACCESS
264 Media in this element is accessible by a picker.
265 .It EXENAB
266 Element supports passing media (exporting) to an outside human operator.
267 .It INENAB
268 Element supports receiving media (importing) from an outside human operator.
269 .El
270 .Sh FILES
271 .Bl -tag -width /dev/ch0 -compact
272 .It Pa /dev/ch0
273 default changer device
274 .El
275 .Sh EXAMPLES
276 .Bl -tag -width indent
277 .It Li chio move slot 3 drive 0
278 Move the media in slot 3 (fourth slot) to drive 0 (first drive).
279 .It Li chio move voltag VOLUME01 drive 0
280 Move the media with the barcode VOLUME01 to drive 0 (first drive).
281 .It Li chio return drive 0
282 Remove the tape from drive 0 (first drive) and return it to its original
283 location in the rack.
284 .It Li chio setpicker 2
285 Configure the changer to use picker 2 (third picker) for operations.
286 .El
287 .Sh SEE ALSO
288 .Xr mt 1 ,
289 .Xr mount 8
290 .Sh AUTHORS
291 .An -nosplit
292 The
293 .Nm
294 program and SCSI changer driver were written by
295 .An Jason R. Thorpe Aq thorpej@and.com
296 for And Communications,
297 .Pa http://www.and.com/ .
298 .Pp
299 Additional work by
300 .An Hans Huebner
301 .Aq hans@artcom.de
302 and
303 .An Steve Gunn
304 .Aq csg@waterspout.com .