2 .\" Copyright (c) 2003 Tom Rhodes
3 .\" All rights reserved.
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\" notice, this list of conditions and the following disclaimer.
10 .\" 2. Redistributions in binary form must reproduce the above copyright
11 .\" notice, this list of conditions and the following disclaimer in the
12 .\" documentation and/or other materials provided with the distribution.
14 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
15 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
16 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
17 .\" ARE DISCLAIMED. IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
18 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
19 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
20 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
21 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
22 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
23 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
33 .Nd IBM/Adaptec ServeRAID controller driver
35 To compile this driver into the kernel,
36 place the following lines in your
37 kernel configuration file:
38 .Bd -ragged -offset indent
44 Alternatively, to load the driver as a
45 module at boot time, place the following line in
47 .Bd -literal -offset indent
53 driver claims to support the
55 (now Adaptec) ServeRAID series
59 These cards come with a built in configuration utility stored in
60 the firmware known as the
62 This utility is accessed with the
64 key combination during the initial card
67 It is highly recommended that this utility be used to configure the card
68 before attempting to diagnose the below error messages.
72 driver can have difficulties attaching during
73 the system initialization period.
74 To avoid these difficulties, set the
77 It will prevent the driver from attaching.
79 Controllers supported by the
96 Newer ServeRAID controllers are supported by the
102 Several error codes may be shown when the card initializes the
105 utility and are independent of
108 .It ips%d: failed to get adapter configuration data from device
109 .It ips%d: failed to get drive configuration data from device
111 Unable to obtain adapter or drive configuration.
112 .It ips%d iobuf error
114 A buffer input/output error has occurred.
117 .Ss General adapter errors:
119 .It Attaching bus failed
121 This message is undocumented.
122 .It WARNING: command timeout. Adapter is in toaster mode, resetting
124 A command timeout has caused the adapter to be reset.
125 .It AIEE! adapter reset failed, giving up and going home! Have a nice day
127 An error occurred while attempting to reset the adapter.
128 .It unable to get adapter configuration
129 .It unable to get drive configuration
131 There was an error when attempting to get configuration information.
132 .It Adapter error during initialization.
133 .It adapter initialization failed
135 There was an error while attempting to initialize the adapter.
136 .It adapter failed config check
137 .It adapter clear failed
139 There was an error while checking the adapter.
140 .It device is disabled
142 The adapter is disabled.
143 .It resource allocation failed
144 .It irq allocation failed
147 The driver was unable to allocate resources for the device.
149 .Ss Error messages due to DMA:
151 .It can't alloc command dma tag
152 .It can't alloc SG dma tag
153 .It can't alloc dma tag for statue queue
156 Failure to map or allocate DMA resources.
158 .Ss Cache, buffer, and command errors:
160 .It failed to initialize command buffers
161 .It no mem for command slots!
168 .It ERROR: unable to get a command! can't flush cache!
169 .It ERROR: cache flush command failed!
170 .It ERROR: unable to get a command! can't update nvram
171 .It ERROR: nvram update command failed!
172 .It ERROR: unable to get a command! can't sync cache!
173 .It ERROR: cache sync command failed!
174 .It ERROR: unable to get a command! can't sync cache!
175 .It ERROR: etable command failed!
178 Unlike many of the other
184 driver does not use the
197 driver was written by
201 .An Scott Long Aq scottl@FreeBSD.org .
203 This manual page was written by
204 .An Tom Rhodes Aq trhodes@FreeBSD.org .