]> CyberLeo.Net >> Repos - FreeBSD/FreeBSD.git/blob - sbin/devd/devd.conf.5
Remove spurious newline
[FreeBSD/FreeBSD.git] / sbin / devd / devd.conf.5
1 .\"
2 .\" Copyright (c) 2002 M. Warner Losh
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .\" The section on comments was taken from named.conf.5, which has the
28 .\" following copyright:
29 .\" Copyright (c) 1999-2000 by Internet Software Consortium
30 .\"
31 .\" Permission to use, copy, modify, and distribute this software for any
32 .\" purpose with or without fee is hereby granted, provided that the above
33 .\" copyright notice and this permission notice appear in all copies.
34 .\"
35 .\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
36 .\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
37 .\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
38 .\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
39 .\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
40 .\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
41 .\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
42 .\" SOFTWARE.
43 .\"
44 .Dd March 29, 2019
45 .Dt DEVD.CONF 5
46 .Os
47 .Sh NAME
48 .Nm devd.conf
49 .Nd configuration file for
50 .Xr devd 8
51 .Sh DESCRIPTION
52 .Ss General Syntax
53 A
54 .Xr devd 8
55 configuration consists of two general features, statements
56 and comments.
57 All statements end with a semicolon.
58 Many statements can contain substatements, which are also
59 terminated with a semicolon.
60 .Pp
61 The following statements are supported:
62 .Bl -tag -width ".Ic options"
63 .It Ic attach
64 Specifies various matching criteria and actions to perform when
65 a newly attached device matches said criteria.
66 .It Ic detach
67 Specifies various matching criteria and actions to perform when
68 a newly detached device matches said criteria.
69 .It Ic nomatch
70 Specifies various matching criteria and actions to perform when
71 no device driver currently loaded in the kernel claims a (new)
72 device.
73 .It Ic notify
74 Specifies various matching criteria and actions to perform when the kernel
75 sends an event notification to userland.
76 .It Ic options
77 Specifies various options and parameters for the operation of
78 .Xr devd 8 .
79 .El
80 .Pp
81 Statements may occur in any order in the configuration file, and may be
82 repeated as often as required.
83 Further details on the syntax and meaning of each statement and their
84 substatements are explained below.
85 .Pp
86 Each statement, except
87 .Ic options
88 has a priority (an arbitrary number) associated with it, where
89 .Ql 0
90 is defined as the lowest priority.
91 If two statements match the same event, only the action of the statement with
92 highest priority will be executed.
93 In this way generic statements can be overridden for devices or
94 notifications that require special attention.
95 .Pp
96 The general syntax of a statement is:
97 .Bd -literal -offset indent
98 statement priority {
99         substatement "value";
100         ...
101         substatement "value";
102 };
103 .Ed
104 .Ss Sub-statements
105 The following sub-statements are supported within the
106 .Ic options
107 statement.
108 .Bl -tag -width ".Ic directory"
109 .It Ic directory Qq Ar /some/path ;
110 Adds the given directory to the list of directories from which
111 .Xr devd 8
112 will read all files named "*.conf" as further
113 configuration files.
114 Any number of
115 .Ic directory
116 statements can be used.
117 .It Ic pid-file Qq Pa /var/run/devd.pid ;
118 Specifies PID file.
119 .It Ic set Ar regexp-name Qq Ar (some|regexp) ;
120 Creates a regular expression and assigns it to the variable
121 .Ar regexp-name .
122 The variable is available throughout the rest of
123 the configuration file.
124 If the string begins with
125 .Ql \&! ,
126 it matches if the regular expression formed by the rest of the string
127 does not match.
128 All regular expressions have an implicit
129 .Ql ^$
130 around them.
131 .El
132 .Pp
133 The following sub-statements are supported within the
134 .Ic attach
135 and
136 .Ic detach
137 statements.
138 .Bl -tag -width ".Ic directory"
139 .It Ic action Qq Ar command ;
140 Command to execute upon a successful match.
141 Example
142 .Dq Li "/etc/pccard_ether $device-name start" .
143 .It Ic class Qq Ar string ;
144 This is shorthand for
145 .Dq Ic match Qo Li class Qc Qq Ar string .
146 .It Ic device-name Qq string ;
147 This is shorthand for
148 .Dq Ic match Qo Li device-name Qc Qq Ar string .
149 This matches a device named
150 .Ar string ,
151 which is allowed to be a regular expression or a variable previously created
152 containing a regular expression.
153 The
154 .Dq Li device-name
155 variable
156 is available for later use with the
157 .Ic action
158 statement.
159 .It Ic match Qo Ar variable Qc Qq Ar value ;
160 Matches the content of
161 .Ar value
162 against
163 .Ar variable ;
164 the content of
165 .Ar value
166 may be a regular expression.
167 Not required during
168 .Ic attach
169 nor
170 .Ic detach
171 events since the
172 .Ic device-name
173 statement takes care of all device matching.
174 For a partial list of variables, see below.
175 .It Ic media-type Qq Ar string ;
176 For network devices,
177 .Ic media-type
178 will match devices that have the given media type.
179 Valid media types are:
180 .Dq Li Ethernet ,
181 .Dq Li Tokenring ,
182 .Dq Li FDDI ,
183 .Dq Li 802.11 ,
184 and
185 .Dq Li ATM .
186 .It Ic subdevice Qq Ar string ;
187 This is shorthand for
188 .Dq Ic match Qo Li subdevice Qc Qq Ar string .
189 .El
190 .Pp
191 The following sub-statements are supported within the
192 .Ic nomatch
193 statement.
194 .Bl -tag -width ".Ic directory"
195 .It Ic action Qq Ar command ;
196 Same as above.
197 .It Ic match Qo Ar variable Qc Qq Ar value ;
198 Matches the content of
199 .Ar value
200 against
201 .Ar variable ;
202 the content of
203 .Ar value
204 may be a regular expression.
205 For a partial list of variables, see below.
206 .El
207 .Pp
208 The following sub-statements are supported within the
209 .Ic notify
210 statement.
211 The
212 .Dq Li notify
213 variable is available inside this statement and contains, a value, depending
214 on which system and subsystem that delivered the event.
215 .Bl -tag -width ".Ic directory"
216 .It Ic action Qq Ar command ;
217 Command to execute upon a successful match.
218 Example
219 .Dq Li "/etc/rc.d/power_profile $notify" .
220 .It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
221 Any number of
222 .Ic match
223 statements can exist within a
224 .Ic notify
225 statement;
226 .Ar value
227 can be either a fixed string or a regular expression.
228 Below is a list of available systems, subsystems, and types.
229 .It Ic media-type Qq Ar string ;
230 See above.
231 .El
232 .Ss Variables that can be used with the match statement
233 A partial list of variables and their possible values that can be used together
234 with the
235 .Ic match
236 statement.
237 The variables are published by the bus based on characteristics of the device
238 that generated the event (for device events).
239 Variables for other classes of events are dependent on those events.
240 .Pp
241 .Bl -tag -width ".Li manufacturer" -compact
242 .It Ic Variable
243 .Ic Description
244 .It Li *
245 The entire message from the current event.
246 .It Li _
247 The entire message from the current event, after the initial type character.
248 .It Li timestamp
249 The time this event was processed, in seconds since 1970 dot fraction.
250 .It Li bus
251 Device name of parent bus.
252 .It Li cdev
253 Device node path if one is created by the
254 .Xr devfs 5
255 filesystem.
256 .It Li cisproduct
257 CIS-product.
258 .It Li cisvendor
259 CIS-vendor.
260 .It Li class
261 Device class.
262 .It Li comm
263 Executable name (kernel).
264 .It Li core
265 Path to core file (kernel).
266 .It Li device
267 Device ID.
268 .It Li devclass
269 Device Class (USB).
270 .It Li devsubclass
271 Device Sub-class (USB).
272 .It Li device-name
273 Name of attached/detached device.
274 .It Li endpoints
275 Endpoint count (USB).
276 .It Li function
277 Card functions.
278 .It Li interface
279 Interface ID (USB).
280 .It Li intclass
281 Interface Class (USB).
282 .It Li intprotocol
283 Interface Protocol (USB).
284 .It Li intsubclass
285 Interface Sub-class (USB).
286 .It Li jail
287 Jail name for the process triggering the rule (RCTL).
288 .It Li manufacturer
289 Manufacturer ID (pccard).
290 .It Li mode
291 Peripheral mode (USB).
292 .It Li notify
293 Match the value of the
294 .Dq Li notify
295 variable.
296 .It Li parent
297 Parent device.
298 .It Li pid
299 PID of the process triggering the rule (RCTL).
300 .It Li port
301 Hub port number (USB).
302 .It Li product
303 Product ID (pccard/USB).
304 .It Li release
305 Hardware revision (USB).
306 .It Li ruid
307 Real UID of the process triggering the rule (RCTL).
308 .It Li rule
309 Rule (RCTL).
310 .It Li sernum
311 Serial Number (USB).
312 .It Li slot
313 Card slot.
314 .It Li subvendor
315 Sub-vendor ID.
316 .It Li subdevice
317 Sub-device ID.
318 .It Li subsystem
319 Matches a subsystem of a system, see below.
320 .It Li system
321 Matches a system type, see below.
322 .It Li type
323 Type of notification, see below.
324 .It Li vendor
325 Vendor ID.
326 .El
327 .Ss Notify matching
328 A partial list of systems, subsystems, and types used within the
329 .Ic notify
330 mechanism.
331 .Pp
332 .Bl -tag -width ".Li coretemp" -compact
333 .It Sy System
334 .It Li ACPI
335 Events related to the ACPI subsystem.
336 .Bl -tag -width ".Sy Subsystem" -compact
337 .It Sy Subsystem
338 .It Li ACAD
339 AC line state ($notify=0x00 is offline, 0x01 is online).
340 .It Li Button
341 Button state ($notify=0x00 is power, 0x01 is sleep).
342 .It Li CMBAT
343 Battery events.
344 .It Li Lid
345 Lid state ($notify=0x00 is closed, 0x01 is open).
346 .It Li PROCESSOR
347 Processor state/configuration ($notify=0x81 is a change in available Cx states).
348 .It Li Resume
349 Resume notification.
350 .It Li Suspend
351 Suspend notification.
352 .It Li Thermal
353 Thermal zone events.
354 .El
355 .Pp
356 .It Li CARP
357 Events related to the
358 .Xr carp 4
359 protocol.
360 .Bl -tag -width ".Sy Subsystem" -compact
361 .It Sy Subsystem
362 .It Ar vhid@interface
363 The
364 .Dq subsystem
365 contains the actual CARP vhid and the name of the network interface
366 on which the event took place.
367 .Bl -tag -width ".Li MASTER" -compact
368 .It Sy Type
369 .It Li MASTER
370 Node become the master for a virtual host.
371 .It Li BACKUP
372 Node become the backup for a virtual host.
373 .El
374 .El
375 .Pp
376 .It Li IFNET
377 Events related to the network subsystem.
378 .Bl -tag -width ".Sy Subsystem" -compact
379 .It Sy Subsystem
380 .It Ar interface
381 The
382 .Dq subsystem
383 is the actual name of the network interface on which the event
384 took place.
385 .Bl -tag -width ".Li LINK_DOWN" -compact
386 .It Sy Type
387 .It Li LINK_UP
388 Carrier status changed to UP.
389 .It Li LINK_DOWN
390 Carrier status changed to DOWN.
391 .It Li ATTACH
392 The network interface is attached to the system.
393 .It Li DETACH
394 The network interface is detached from the system.
395 .El
396 .El
397 .Pp
398 .It Li DEVFS
399 Events related to the
400 .Xr devfs 5
401 filesystem.
402 .Bl -tag -width ".Sy Subsystem" -compact
403 .It Sy Subsystem
404 .It Li CDEV
405 .Bl -tag -width ".Li DESTROY" -compact
406 .It Sy Type
407 .It Li CREATE
408 The
409 .Xr devfs 5
410 node is created.
411 .It Li DESTROY
412 The
413 .Xr devfs 5
414 node is destroyed.
415 .El
416 .El
417 .Pp
418 .It Li GEOM
419 Events related to the
420 .Xr geom 4
421 framework.
422 The difference compared to
423 .Li DEVFS
424 is that
425 .Li GEOM
426 only includes disk-like devices.
427 .Bl -tag -width ".Sy Subsystem" -compact
428 .It Sy Subsystem
429 .It Li DEV
430 .Bl -tag -width ".Li MEDIACHANGE" -compact
431 .It Sy Type
432 .It Li CREATE
433 A
434 .Xr geom 4
435 provider is created.
436 .It Li DESTROY
437 A
438 .Xr geom 4
439 provider is destroyed.
440 .It Li GEOM::physpath
441 The physical path of a device has changed.
442 .It Li MEDIACHANGE
443 Physical media has changed.
444 .It Li SIZECHANGE
445 A
446 .Xr geom 4
447 provider size has changed.
448 .El
449 .El
450 .Pp
451 .It Li RCTL
452 Events related to the
453 .Xr rctl 8
454 framework.
455 .Bl -tag -width ".Sy Subsystem" -compact
456 .It Sy Subsystem
457 .It Li rule
458 .Bl -tag -width ".Li matched" -compact
459 .It Sy Type
460 .It Li matched
461 A rule with action specified as "devctl" was triggered.
462 .El
463 .El
464 .Pp
465 .It Li USB
466 Events related to the USB subsystem.
467 .Bl -tag -width ".Sy Subsystem" -compact
468 .It Sy Subsystem
469 .It Li DEVICE
470 .Bl -tag -width ".Li DETACH" -compact
471 .It Sy Type
472 .It Li ATTACH
473 USB device is attached to the system.
474 .It Li DETACH
475 USB device is detached from the system.
476 .El
477 .It Li INTERFACE
478 .Bl -tag -width ".Li DETACH" -compact
479 .It Sy Type
480 .It Li ATTACH
481 USB interface is attached to a device.
482 .It Li DETACH
483 USB interface is detached from a device.
484 .El
485 .El
486 .Pp
487 .It Li coretemp
488 Events related to the
489 .Xr coretemp 4
490 device.
491 .Bl -tag -width ".Sy Subsystem" -compact
492 .It Sy Subsystem
493 .It Li Thermal
494 Notification that the CPU core has reached critical temperature.
495 .Bl -tag -width ".Ar temperature" -compact
496 .It Sy Type
497 .It Ar temperature
498 String containing the temperature of the core that has become too hot.
499 .El
500 .El
501 .Pp
502 .It Li kern
503 Events related to the kernel.
504 .Bl -tag -width ".Sy Subsystem" -compact
505 .It Sy Subsystem
506 .It Li power
507 .Bl -tag -width ".li resume" -compact
508 .It Sy Type
509 .It Li resume
510 Notification that the system has woken from the suspended state.
511 .El
512 .El
513 .Pp
514 .It Li kernel
515 More events related to the kernel.
516 .Bl -tag -width ".Sy Subsystem" -compact
517 .It Sy Subsystem
518 .It Li signal
519 .Bl -tag -width ".li resume" -compact
520 .It Sy Type
521 .It Li coredump
522 Notification that a process has crashed and dumped core.
523 .El
524 .El
525 .Pp
526 .It Li CAM
527 Events related to the
528 .Xr cam 4
529 system.
530 .Bl -tag -width ".Sy Subsystem" -compact
531 .It Sy Subsystem
532 .It Li periph
533 Events related to peripheral devices.
534 .Bl -tag -width ".li timeout" -compact
535 .It Sy Type
536 .It Li error
537 Generic errors.
538 .It Li timeout
539 Command timeouts.
540 .El
541 .El
542 .El
543 .Pp
544 A link state change to UP on the interface
545 .Dq Li fxp0
546 would result in the following notify event:
547 .Bd -literal -offset indent
548 system=IFNET, subsystem=fxp0, type=LINK_UP
549 .Ed
550 .Pp
551 An AC line state change to
552 .Dq offline
553 would result in the following event:
554 .Bd -literal -offset indent
555 system=ACPI, subsystem=ACAD, notify=0x00
556 .Ed
557 .Ss Comments
558 Comments may appear anywhere that whitespace may appear in a
559 configuration file.
560 To appeal to programmers of all kinds, they can
561 be written in C, C++, or shell/Perl constructs.
562 .Pp
563 C-style comments start with the two characters
564 .Ql /*
565 (slash, star) and end with
566 .Ql */
567 (star, slash).
568 Because they are completely delimited with these characters,
569 they can be used to comment only a portion of a line or to span
570 multiple lines.
571 .Pp
572 C-style comments cannot be nested.
573 For example, the following is
574 not valid because the entire comment ends with the first
575 .Ql */ :
576 .Bd -literal -offset indent
577 /* This is the start of a comment.
578    This is still part of the comment.
579 /* This is an incorrect attempt at nesting a comment. */
580    This is no longer in any comment. */
581 .Ed
582 .Pp
583 C++-style comments start with the two characters
584 .Ql //
585 (slash, slash) and continue to the end of the physical line.
586 They cannot be continued across multiple physical lines; to have
587 one logical comment span multiple lines, each line must use the
588 .Ql //
589 pair.
590 For example:
591 .Bd -literal -offset indent
592 // This is the start of a comment.  The next line
593 // is a new comment, even though it is logically
594 // part of the previous comment.
595 .Ed
596 .Sh FILES
597 .Bl -tag -width ".Pa /etc/devd.conf" -compact
598 .It Pa /etc/devd.conf
599 The
600 .Xr devd 8
601 configuration file.
602 .El
603 .Sh EXAMPLES
604 .Bd -literal
605 #
606 # This will catch link down events on the interfaces fxp0 and ath0
607 #
608 notify 0 {
609         match "system"                  "IFNET";
610         match "subsystem"               "(fxp0|ath0)";
611         match "type"                    "LINK_DOWN";
612         action "logger $subsystem is DOWN";
613 };
614
615 #
616 # Match lid open/close events
617 # These can be combined to a single event, by passing the
618 # value of $notify to the external script.
619 #
620 notify 0 {
621         match "system"                  "ACPI";
622         match "subsystem"               "Lid";
623         match "notify"                  "0x00";
624         action "logger Lid closed, we can sleep now!";
625 };
626
627 notify 0 {
628         match "system"                  "ACPI";
629         match "subsystem"               "Lid";
630         match "notify"                  "0x01";
631         action "logger Lid opened, the sleeper must awaken!";
632 };
633
634 #
635 # Match a USB device type
636 #
637 notify 0 {
638         match "system"                  "USB";
639         match "subsystem"               "INTERFACE";
640         match "type"                    "ATTACH";
641         match "intclass"                "0x0e";
642         action "logger USB video device attached";
643 };
644
645 #
646 # Try to configure ath and wi devices with pccard_ether
647 # as they are attached.
648 #
649 attach 0 {
650         device-name "(ath|wi)[0-9]+";
651         action "/etc/pccard_ether $device-name start";
652 };
653
654 #
655 # Stop ath and wi devices as they are detached from
656 # the system.
657 #
658 detach 0 {
659         device-name "(ath|wi)[0-9]+";
660         action "/etc/pccard_ether $device-name stop";
661 };
662 .Ed
663 .Pp
664 The installed
665 .Pa /etc/devd.conf
666 has many additional examples.
667 .Sh SEE ALSO
668 .Xr cam 4 ,
669 .Xr coretemp 4 ,
670 .Xr devfs 5 ,
671 .Xr re_format 7 ,
672 .Xr devd 8