]> CyberLeo.Net >> Repos - FreeBSD/FreeBSD.git/blob - share/man/man4/acpi_thermal.4
This commit was generated by cvs2svn to compensate for changes in r159825,
[FreeBSD/FreeBSD.git] / share / man / man4 / acpi_thermal.4
1 .\" Copyright (c) 2003 Takanori Watanabe.
2 .\" All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .Dd December 27, 2003
28 .Dt ACPI_THERMAL 4
29 .Os
30 .Sh NAME
31 .Nm acpi_thermal
32 .Nd ACPI thermal management subsystem
33 .Sh SYNOPSIS
34 .Cd "device acpi"
35 .Sh DESCRIPTION
36 The
37 .Nm
38 driver provides the thermal management features of the ACPI module.
39 This driver has a
40 .Xr sysctl 8
41 interface and a
42 .Xr devd 8
43 notification interface.
44 The sysctls export properties of each ACPI thermal zone object.
45 .Pp
46 There can be multiple thermal zones in a system.
47 For example, each CPU and the enclosure could all be separate thermal
48 zones, each with its own setpoints and cooling devices.
49 Thermal zones are numbered sequentially in the order they appear in
50 the AML.
51 .Pp
52 The
53 .Nm
54 driver also activates the active cooling system according to
55 each thermal zone's setpoints.
56 .Sh SYSCTL VARIABLES
57 .Bl -tag -width indent
58 .It Va hw.acpi.thermal.tz%d.active
59 Current active cooling system state.
60 If this is non-negative, the appropriate _AC%d object is running.
61 Set this value to the desired active cooling level to force
62 the corresponding fan object to the appropriate level.
63 .It Va hw.acpi.thermal.tz%d.passive_cooling
64 If set to 1, passive cooling is enabled.
65 It does cooling without fans using
66 .Xr cpufreq 4
67 as the mechanism for controlling CPU speed.
68 Default is enabled for tz0 where it is available.
69 .It Va hw.acpi.thermal.tz%d.thermal_flags
70 Current thermal zone status.
71 These are bit-masked values.
72 .It Va hw.acpi.thermal.tz%d.temperature
73 Current temperature for this zone.
74 .It Va hw.acpi.thermal.tz%d._PSV
75 Temperature to start passive cooling by throttling down CPU, etc.
76 .It Va hw.acpi.thermal.tz%d._HOT
77 Temperature to start critical suspend to disk (S4).
78 .It Va hw.acpi.thermal.tz%d._CRT
79 Temperature to start critical shutdown (S5).
80 .It Va hw.acpi.thermal.tz%d._ACx
81 Temperatures at which to switch to the corresponding active cooling
82 level.
83 For instance, values of
84 .Qq Li "3200 3100"
85 mean to switch on _AC0 at 320.0K
86 and _AC1 at 310.0K.
87 The lower the _ACx value, the higher the cooling power.
88 .El
89 .Pp
90 All temperatures are represented in tenths of a Kelvin.
91 For example, 300.0K is represented by the integer 3000.
92 To convert to units of Centigrade,
93 the formula is
94 .Li "(x - 2731.5) / 10" .
95 .Sh NOTIFIES
96 Notifies are passed to userland via
97 .Xr devd 8 .
98 See
99 .Pa /etc/devd.conf
100 and
101 .Xr devd.conf 5
102 for examples.
103 The
104 .Nm
105 driver sends events with the following attributes:
106 .Pp
107 .Bl -tag -width "subsystem" -compact
108 .It system
109 .Li ACPI
110 .It subsystem
111 .Li Thermal
112 .It type
113 The fully qualified thermal zone object path as in the ASL.
114 .It notify
115 An integer designating the event:
116 .Pp
117 .Bl -tag -width indent -compact
118 .It Li 0x80
119 Current temperature has changed.
120 .It Li 0x81
121 One or more trip points (_ACx, _PSV) have changed.
122 .It Li 0x82
123 One or more device lists (_ALx, _PSL, _TZD) have changed.
124 .It Li 0xcc
125 Non-standard notify that the system will shutdown if the temperature
126 stays above _CRT or _HOT for one more poll cycle.
127 .El
128 .El
129 .Sh SEE ALSO
130 .Xr acpi 4 ,
131 .Xr cpufreq 4 ,
132 .Xr acpidump 8
133 .Sh AUTHORS
134 .An -nosplit
135 .An Michael Smith
136 .Pp
137 This manual page was written by
138 .An Takanori Watanabe .