]> CyberLeo.Net >> Repos - FreeBSD/FreeBSD.git/blob - sys/amd64/vmm/x86.c
Bring back part of r249367 by adding DTrace's temporal option, which allows
[FreeBSD/FreeBSD.git] / sys / amd64 / vmm / x86.c
1 /*-
2  * Copyright (c) 2011 NetApp, Inc.
3  * All rights reserved.
4  *
5  * Redistribution and use in source and binary forms, with or without
6  * modification, are permitted provided that the following conditions
7  * are met:
8  * 1. Redistributions of source code must retain the above copyright
9  *    notice, this list of conditions and the following disclaimer.
10  * 2. Redistributions in binary form must reproduce the above copyright
11  *    notice, this list of conditions and the following disclaimer in the
12  *    documentation and/or other materials provided with the distribution.
13  *
14  * THIS SOFTWARE IS PROVIDED BY NETAPP, INC ``AS IS'' AND
15  * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
16  * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
17  * ARE DISCLAIMED.  IN NO EVENT SHALL NETAPP, INC OR CONTRIBUTORS BE LIABLE
18  * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
19  * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
20  * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
21  * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
22  * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
23  * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
24  * SUCH DAMAGE.
25  *
26  * $FreeBSD$
27  */
28
29 #include <sys/cdefs.h>
30 __FBSDID("$FreeBSD$");
31
32 #include <sys/param.h>
33 #include <sys/types.h>
34 #include <sys/systm.h>
35 #include <sys/cpuset.h>
36
37 #include <machine/clock.h>
38 #include <machine/cpufunc.h>
39 #include <machine/md_var.h>
40 #include <machine/specialreg.h>
41
42 #include <machine/vmm.h>
43
44 #include "x86.h"
45
46 #define CPUID_VM_HIGH           0x40000000
47
48 static const char bhyve_id[12] = "BHyVE BHyVE ";
49
50 int
51 x86_emulate_cpuid(struct vm *vm, int vcpu_id,
52                   uint32_t *eax, uint32_t *ebx, uint32_t *ecx, uint32_t *edx)
53 {
54         int error;
55         unsigned int    func, regs[4];
56         enum x2apic_state x2apic_state;
57
58         /*
59          * Requests for invalid CPUID levels should map to the highest
60          * available level instead.
61          */
62         if (cpu_exthigh != 0 && *eax >= 0x80000000) {
63                 if (*eax > cpu_exthigh)
64                         *eax = cpu_exthigh;
65         } else if (*eax >= 0x40000000) {
66                 if (*eax > CPUID_VM_HIGH)
67                         *eax = CPUID_VM_HIGH;
68         } else if (*eax > cpu_high) {
69                 *eax = cpu_high;
70         }
71
72         func = *eax;
73
74         /*
75          * In general the approach used for CPU topology is to
76          * advertise a flat topology where all CPUs are packages with
77          * no multi-core or SMT.
78          */
79         switch (func) {
80                 case CPUID_0000_0000:
81                 case CPUID_0000_0002:
82                 case CPUID_0000_0003:
83                 case CPUID_0000_000A:
84                         cpuid_count(*eax, *ecx, regs);
85                         break;
86
87                 case CPUID_8000_0000:
88                 case CPUID_8000_0001:
89                 case CPUID_8000_0002:
90                 case CPUID_8000_0003:
91                 case CPUID_8000_0004:
92                 case CPUID_8000_0006:
93                 case CPUID_8000_0008:
94                         cpuid_count(*eax, *ecx, regs);
95                         break;
96
97                 case CPUID_8000_0007:
98                         cpuid_count(*eax, *ecx, regs);
99                         /*
100                          * If the host TSCs are not synchronized across
101                          * physical cpus then we cannot advertise an
102                          * invariant tsc to a vcpu.
103                          *
104                          * XXX This still falls short because the vcpu
105                          * can observe the TSC moving backwards as it
106                          * migrates across physical cpus. But at least
107                          * it should discourage the guest from using the
108                          * TSC to keep track of time.
109                          */
110                         if (!smp_tsc)
111                                 regs[3] &= ~AMDPM_TSC_INVARIANT;
112                         break;
113
114                 case CPUID_0000_0001:
115                         do_cpuid(1, regs);
116
117                         error = vm_get_x2apic_state(vm, vcpu_id, &x2apic_state);
118                         if (error) {
119                                 panic("x86_emulate_cpuid: error %d "
120                                       "fetching x2apic state", error);
121                         }
122
123                         /*
124                          * Override the APIC ID only in ebx
125                          */
126                         regs[1] &= ~(CPUID_LOCAL_APIC_ID);
127                         regs[1] |= (vcpu_id << CPUID_0000_0001_APICID_SHIFT);
128
129                         /*
130                          * Don't expose VMX, SpeedStep or TME capability.
131                          * Advertise x2APIC capability and Hypervisor guest.
132                          */
133                         regs[2] &= ~(CPUID2_VMX | CPUID2_EST | CPUID2_TM2);
134
135                         regs[2] |= CPUID2_HV;
136
137                         if (x2apic_state != X2APIC_DISABLED)
138                                 regs[2] |= CPUID2_X2APIC;
139
140                         /*
141                          * Hide xsave/osxsave/avx until the FPU save/restore
142                          * issues are resolved
143                          */
144                         regs[2] &= ~(CPUID2_XSAVE | CPUID2_OSXSAVE |
145                                      CPUID2_AVX);
146
147                         /*
148                          * Hide monitor/mwait until we know how to deal with
149                          * these instructions.
150                          */
151                         regs[2] &= ~CPUID2_MON;
152
153                         /*
154                          * Hide thermal monitoring
155                          */
156                         regs[3] &= ~(CPUID_ACPI | CPUID_TM);
157                         
158                         /*
159                          * Machine check handling is done in the host.
160                          * Hide MTRR capability.
161                          */
162                         regs[3] &= ~(CPUID_MCA | CPUID_MCE | CPUID_MTRR);
163
164                         /*
165                          * Disable multi-core.
166                          */
167                         regs[1] &= ~CPUID_HTT_CORES;
168                         regs[3] &= ~CPUID_HTT;
169                         break;
170
171                 case CPUID_0000_0004:
172                         do_cpuid(4, regs);
173
174                         /*
175                          * Do not expose topology.
176                          */
177                         regs[0] &= 0xffff8000;
178                         regs[0] |= 0x04008000;
179                         break;
180
181                 case CPUID_0000_0006:
182                 case CPUID_0000_0007:
183                         /*
184                          * Handle the access, but report 0 for
185                          * all options
186                          */
187                         regs[0] = 0;
188                         regs[1] = 0;
189                         regs[2] = 0;
190                         regs[3] = 0;
191                         break;
192
193                 case CPUID_0000_000B:
194                         /*
195                          * Processor topology enumeration
196                          */
197                         regs[0] = 0;
198                         regs[1] = 0;
199                         regs[2] = *ecx & 0xff;
200                         regs[3] = vcpu_id;
201                         break;
202
203                 case 0x40000000:
204                         regs[0] = CPUID_VM_HIGH;
205                         bcopy(bhyve_id, &regs[1], 4);
206                         bcopy(bhyve_id, &regs[2], 4);
207                         bcopy(bhyve_id, &regs[3], 4);
208                         break;
209                 default:
210                         /* XXX: Leaf 5? */
211                         return (0);
212         }
213
214         *eax = regs[0];
215         *ebx = regs[1];
216         *ecx = regs[2];
217         *edx = regs[3];
218         return (1);
219 }