]> CyberLeo.Net >> Repos - FreeBSD/FreeBSD.git/blob - sys/geom/vinum/geom_vinum_volume.c
Upgrade to version 3.1.4
[FreeBSD/FreeBSD.git] / sys / geom / vinum / geom_vinum_volume.c
1 /*-
2  * SPDX-License-Identifier: BSD-2-Clause-FreeBSD
3  *
4  * Copyright (c) 2007 Lukas Ertl
5  * All rights reserved.
6  *
7  * Redistribution and use in source and binary forms, with or without
8  * modification, are permitted provided that the following conditions
9  * are met:
10  * 1. Redistributions of source code must retain the above copyright
11  *    notice, this list of conditions and the following disclaimer.
12  * 2. Redistributions in binary form must reproduce the above copyright
13  *    notice, this list of conditions and the following disclaimer in the
14  *    documentation and/or other materials provided with the distribution.
15  *
16  * THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
17  * ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
18  * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
19  * ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
20  * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
21  * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
22  * OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
23  * HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
24  * LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
25  * OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
26  * SUCH DAMAGE.
27  */
28
29 #include <sys/cdefs.h>
30 __FBSDID("$FreeBSD$");
31
32 #include <sys/param.h>
33 #include <sys/bio.h>
34 #include <sys/lock.h>
35 #include <sys/malloc.h>
36 #include <sys/systm.h>
37
38 #include <geom/geom.h>
39 #include <geom/vinum/geom_vinum_var.h>
40 #include <geom/vinum/geom_vinum.h>
41
42 void
43 gv_volume_flush(struct gv_volume *v)
44 {
45         struct gv_softc *sc;
46         struct bio *bp;
47
48         KASSERT(v != NULL, ("NULL v"));
49         sc = v->vinumconf;
50         KASSERT(sc != NULL, ("NULL sc"));
51
52         bp = bioq_takefirst(v->wqueue);
53         while (bp != NULL) {
54                 gv_volume_start(sc, bp);
55                 bp = bioq_takefirst(v->wqueue);
56         }
57 }
58
59 void
60 gv_volume_start(struct gv_softc *sc, struct bio *bp)
61 {
62         struct g_geom *gp;
63         struct gv_volume *v;
64         struct gv_plex *p, *lp;
65         int numwrites;
66
67         gp = sc->geom;
68         v = bp->bio_to->private;
69         if (v == NULL || v->state != GV_VOL_UP) {
70                 g_io_deliver(bp, ENXIO);
71                 return;
72         }
73
74         switch (bp->bio_cmd) {
75         case BIO_READ:
76                 /*
77                  * Try to find a good plex where we can send the request to,
78                  * round-robin-style.  The plex either has to be up, or it's a
79                  * degraded RAID5 plex. Check if we have delayed requests. Put
80                  * this request on the delayed queue if so. This makes sure that
81                  * we don't read old values.
82                  */
83                 if (bioq_first(v->wqueue) != NULL) {
84                         bioq_insert_tail(v->wqueue, bp);
85                         break;
86                 }
87                 lp = v->last_read_plex;
88                 if (lp == NULL)
89                         lp = LIST_FIRST(&v->plexes);
90                 p = LIST_NEXT(lp, in_volume);
91                 if (p == NULL)
92                         p = LIST_FIRST(&v->plexes);
93                 do {
94                         if (p == NULL) {
95                                 p = lp;
96                                 break;
97                         }
98                         if ((p->state > GV_PLEX_DEGRADED) ||
99                             (p->state >= GV_PLEX_DEGRADED &&
100                             p->org == GV_PLEX_RAID5))
101                                 break;
102                         p = LIST_NEXT(p, in_volume);
103                         if (p == NULL)
104                                 p = LIST_FIRST(&v->plexes);
105                 } while (p != lp);
106
107                 if ((p == NULL) ||
108                     (p->org == GV_PLEX_RAID5 && p->state < GV_PLEX_DEGRADED) ||
109                     (p->org != GV_PLEX_RAID5 && p->state <= GV_PLEX_DEGRADED)) {
110                         g_io_deliver(bp, ENXIO);
111                         return;
112                 }
113                 v->last_read_plex = p;
114
115                 /* Hand it down to the plex logic. */
116                 gv_plex_start(p, bp);
117                 break;
118
119         case BIO_WRITE:
120         case BIO_DELETE:
121                 /* Delay write-requests if any plex is synchronizing. */
122                 LIST_FOREACH(p, &v->plexes, in_volume) {
123                         if (p->flags & GV_PLEX_SYNCING) {
124                                 bioq_insert_tail(v->wqueue, bp);
125                                 return;
126                         }
127                 }
128
129                 numwrites = 0;
130                 /* Give the BIO to each plex of this volume. */
131                 LIST_FOREACH(p, &v->plexes, in_volume) {
132                         if (p->state < GV_PLEX_DEGRADED)
133                                 continue;
134                         gv_plex_start(p, bp);
135                         numwrites++;
136                 }
137                 if (numwrites == 0)
138                         g_io_deliver(bp, ENXIO);
139                 break;
140         }
141 }
142
143 void
144 gv_bio_done(struct gv_softc *sc, struct bio *bp)
145 {
146         struct gv_volume *v;
147         struct gv_plex *p;
148         struct gv_sd *s;
149
150         s = bp->bio_caller1;
151         KASSERT(s != NULL, ("gv_bio_done: NULL s"));
152         p = s->plex_sc;
153         KASSERT(p != NULL, ("gv_bio_done: NULL p"));
154         v = p->vol_sc;
155         KASSERT(v != NULL, ("gv_bio_done: NULL v"));
156
157         switch (p->org) {
158         case GV_PLEX_CONCAT:
159         case GV_PLEX_STRIPED:
160                 gv_plex_normal_done(p, bp);
161                 break;
162         case GV_PLEX_RAID5:
163                 gv_plex_raid5_done(p, bp);
164                 break;
165         }
166
167         gv_drive_done(s->drive_sc);
168 }