1 .\" Copyright (c) 2008, 2009 Yahoo!, Inc.
2 .\" All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\" 3. The names of the authors may not be used to endorse or promote
13 .\"    products derived from this software without specific prior written
14 .\"    permission.
15 .\"
16 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
17 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
18 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
19 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
20 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
21 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
22 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
23 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
24 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
25 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
26 .\" SUCH DAMAGE.
27 .\"
28 .\" $FreeBSD$
29 .\"
30 .Dd September 2, 2011
31 .Dt MFIUTIL 8
32 .Os
33 .Sh NAME
34 .Nm mfiutil
35 .Nd Utility for managing LSI MegaRAID SAS controllers
36 .Sh SYNOPSIS
37 .Nm
38 .Cm version
39 .Nm
40 .Op Fl u Ar unit
41 .Cm show adapter
42 .Nm
43 .Op Fl u Ar unit
44 .Cm show battery
45 .Nm
46 .Op Fl d
47 .Op Fl e
48 .Op Fl u Ar unit
49 .Cm show config
50 .Nm
51 .Op Fl u Ar unit
52 .Cm show drives
53 .Nm
54 .Op Fl u Ar unit
55 .Cm show events
56 .Op Fl c Ar class
57 .Op Fl l Ar locale
58 .Op Fl n Ar count
59 .Op Fl v
60 .Op Ar start Op Ar stop
61 .Nm
62 .Op Fl u Ar unit
63 .Cm show firmware
64 .Nm
65 .Op Fl u Ar unit
66 .Cm show foreign Op Ar volume
67 .Nm
68 .Op Fl u Ar unit
69 .Cm show logstate
70 .Nm
71 .Op Fl d
72 .Op Fl e
73 .Op Fl u Ar unit
74 .Cm show patrol
75 .Nm
76 .Op Fl d
77 .Op Fl e
78 .Op Fl u Ar unit
79 .Cm show progress
80 .Nm
81 .Op Fl u Ar unit
82 .Cm show volumes
83 .Nm
84 .Op Fl u Ar unit
85 .Cm fail Ar drive
86 .Nm
87 .Op Fl u Ar unit
88 .Cm good Ar drive
89 .Nm
90 .Op Fl u Ar unit
91 .Cm rebuild Ar drive
92 .Nm
93 .Op Fl u Ar unit
94 .Cm syspd Ar drive
95 .Nm
96 .Op Fl u Ar unit
97 .Cm drive progress Ar drive
98 .Nm
99 .Op Fl u Ar unit
100 .Cm drive clear Ar drive Brq "start | stop"
101 .Nm
102 .Op Fl u Ar unit
103 .Cm start rebuild Ar drive
104 .Nm
105 .Op Fl u Ar unit
106 .Cm abort rebuild Ar drive
107 .Nm
108 .Op Fl u Ar unit
109 .Cm locate Ar drive Brq "on | off"
110 .Nm
111 .Op Fl u Ar unit
112 .Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
113 .Nm
114 .Op Fl u Ar unit
115 .Cm name Ar volume Ar name
116 .Nm
117 .Op Fl u Ar unit
118 .Cm volume progress Ar volume
119 .Nm
120 .Op Fl u Ar unit
121 .Cm clear
122 .Nm
123 .Op Fl u Ar unit
124 .Cm create Ar type
125 .Op Fl v
126 .Op Fl s Ar stripe_size
127 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
128 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
129 .Nm
130 .Op Fl u Ar unit
131 .Cm delete Ar volume
132 .Nm
133 .Op Fl u Ar unit
134 .Cm add Ar drive Op Ar volume
135 .Nm
136 .Op Fl u Ar unit
137 .Cm remove Ar drive
138 .Nm
139 .Op Fl u Ar unit
140 .Cm start patrol
141 .Nm
142 .Op Fl u Ar unit
143 .Cm stop patrol
144 .Nm
145 .Op Fl u Ar unit
146 .Cm patrol Ar command Op Ar interval Op Ar start
147 .Nm
148 .Op Fl u Ar unit
149 .Cm foreign scan
150 .Nm
151 .Op Fl u Ar unit
152 .Cm foreign clear Op Ar config
153 .Nm
154 .Op Fl u Ar unit
155 .Cm foreign diag Op Ar config
156 .Nm
157 .Op Fl u Ar unit
158 .Cm foreign preview Op Ar config
159 .Nm
160 .Op Fl u Ar unit
161 .Cm foreign import Op Ar config
162 .Nm
163 .Op Fl u Ar unit
164 .Cm flash Ar file
165 .Nm
166 .Op Fl u Ar unit
167 .Cm start learn
168 .Nm
169 .Op Fl u Ar unit
170 .Cm bbu Ar setting Ar value
171 .Nm
172 .Op Fl u Ar unit
173 .Cm ctrlprop Ar rebuild Op Ar rate
174 .Nm
175 .Op Fl u Ar unit
176 .Cm ctrlprop Ar alarm Op Ar 0/1
177 .Sh DESCRIPTION
178 The
179 .Nm
180 utility can be used to display or modify various parameters on LSI
181 MegaRAID SAS RAID controllers.
182 Each invocation of
183 .Nm
184 consists of zero or more global options followed by a command.
185 Commands may support additional optional or required arguments after the
186 command.
187 .Pp
188 Currently one global option is supported:
189 .Bl -tag -width indent
190 .It Fl u Ar unit
191 .Ar unit
192 specifies the unit of the controller to work with.
193 If no unit is specified,
194 then unit 0 is used.
195 .El
196 .Pp
197 Various commands accept either or both of the two options:
198 .Bl -tag -width indent
199 .It Fl d
200 Print numeric device IDs as drive identifier.
201 This is the default.
202 Useful in combination with
203 .Fl e
204 to print both, numeric device IDs and enclosure:slot information.
205 .It Fl e
206 Print drive identifiers in enclosure:slot form.
207 See next paragraph on format details in context of input rather than
208 output.
209 .El
210 .Pp
211 Drives may be specified in two forms.
212 First,
213 a drive may be identified by its device ID.
214 The device ID for configured drives can be found in
215 .Cm show config .
216 Second,
217 a drive may be identified by its location as
218 .Sm off
219 .Op E Ar xx Ns \&:
220 .Li S Ns Ar yy
221 .Sm on
222 where
223 .Ar xx
224 is the enclosure
225 and
226 .Ar yy
227 is the slot for each drive as displayed in
228 .Cm show drives .
229 .Pp
230 Volumes may be specified in two forms.
231 First,
232 a volume may be identified by its target ID.
233 Second,
234 on the volume may be specified by the corresponding
235 .Em mfidX
236 device,
237 such as
238 .Em mfid0 .
239 .Pp
240 The
241 .Nm
242 utility supports several different groups of commands.
243 The first group of commands provide information about the controller,
244 the volumes it manages, and the drives it controls.
245 The second group of commands are used to manage the physical drives
246 attached to the controller.
247 The third group of commands are used to manage the logical volumes
248 managed by the controller.
249 The fourth group of commands are used to manage the drive configuration for
250 the controller.
251 The fifth group of commands are used to manage controller-wide operations.
252 .Pp
253 The informational commands include:
254 .Bl -tag -width indent
255 .It Cm version
256 Displays the version of
257 .Nm .
258 .It Cm show adapter
259 Displays information about the RAID controller such as the model number.
260 .It Cm show battery
261 Displays information about the battery from the battery backup unit.
262 .It Cm show config
263 Displays the volume and drive configuration for the controller.
264 Each array is listed along with the physical drives the array is built from.
265 Each volume is listed along with the arrays that the volume spans.
266 If any hot spare drives are configured, then they are listed as well.
267 .It Cm show drives
268 Lists all of the physical drives attached to the controller.
269 .It Xo Cm show events
270 .Op Fl c Ar class
271 .Op Fl l Ar locale
272 .Op Fl n Ar count
273 .Op Fl v
274 .Op Ar start Op Ar stop
275 .Xc
276 Display entries from the controller's event log.
277 The controller maintains a circular buffer of events.
278 Each event is tagged with a class and locale.
279 .Pp
280 The
281 .Ar class
282 parameter limits the output to entries at the specified class or higher.
283 The default class is
284 .Dq warn .
285 The available classes from lowest priority to highest are:
286 .Bl -tag -width indent
287 .It Cm debug
288 Debug messages.
289 .It Cm progress
290 Periodic progress updates for long-running operations such as background
291 initializations, array rebuilds, or patrol reads.
292 .It Cm info
293 Informational messages such as drive insertions and volume creations.
294 .It Cm warn
295 Indicates that some component may be close to failing.
296 .It Cm crit
297 A component has failed, but no data is lost.
298 For example, a volume becoming degraded due to a drive failure.
299 .It Cm fatal
300 A component has failed resulting in data loss.
301 .It Cm dead
302 The controller itself has died.
303 .El
304 .Pp
305 The
306 .Ar locale
307 parameter limits the output to entries for the specified part of the controller.
308 The default locale is
309 .Dq all .
310 The available locales are
311 .Dq volume ,
312 .Dq drive ,
313 .Dq enclosure ,
314 .Dq battery ,
315 .Dq sas ,
316 .Dq controller ,
317 .Dq config ,
318 .Dq cluster ,
319 and
320 .Dq all .
321 .Pp
322 The
323 .Ar count
324 parameter is a debugging aid that specifies the number of events to fetch from
325 the controller for each low-level request.
326 The default is 15 events.
327 .Pp
328 By default, matching event log entries from the previous shutdown up to the
329 present are displayed.
330 This range can be adjusted via the
331 .Ar start
332 and
333 .Ar stop
334 parameters.
335 Each of these parameters can either be specified as a log entry number or as
336 one of the following aliases:
337 .Bl -tag -width indent
338 .It Cm newest
339 The newest entry in the event log.
340 .It Cm oldest
341 The oldest entry in the event log.
342 .It Cm clear
343 The first entry since the event log was cleared.
344 .It Cm shutdown
345 The entry in the event log corresponding to the last time the controller was
346 cleanly shut down.
347 .It Cm boot
348 The entry in the event log corresponding to the most recent boot.
349 .El
350 .It Cm show firmware
351 Lists all of the firmware images present on the controller.
352 .It Cm show foreign
353 Displays detected foreign configurations on disks for importation or removal.
354 .It Cm show logstate
355 Display the various sequence numbers associated with the event log.
356 .It Cm show patrol
357 Display the status of the controller's patrol read operation.
358 .It Cm show progress
359 Report the current progress and estimated completion time for active
360 operations on all volumes and drives.
361 .It Cm show volumes
362 Lists all of the logical volumes managed by the controller.
363 .El
364 .Pp
365 The physical drive management commands include:
366 .Bl -tag -width indent
367 .It Cm fail Ar drive
368 Mark
369 .Ar drive
370 as failed.
371 .Ar Drive
372 must be an online drive that is part of an array.
373 .It Cm good Ar drive
374 Mark
375 .Ar drive
376 as an unconfigured good drive.
377 .Ar Drive
378 must not be part of an existing array.
379 .It Cm rebuild Ar drive
380 Mark a failed
381 .Ar drive
382 that is still part of an array as a good drive suitable for a rebuild.
383 The firmware should kick off an array rebuild on its own if a failed drive
384 is marked as a rebuild drive.
385 .It Cm syspd Ar drive
386 Present the drive to the host operating system as a disk SYSPD block device in
387 the format /dev/mfisyspdX.
388 Clear this flag with
389 .Cm good
390 .Ar drive
391 .It Cm drive progress Ar drive
392 Report the current progress and estimated completion time of drive operations
393 such as rebuilds or patrol reads.
394 .It Cm drive clear Ar drive Brq "start | stop"
395 Start or stop the writing of all 0x00 characters to a drive.
396 .It Cm start rebuild Ar drive
397 Manually start a rebuild on
398 .Ar drive .
399 .It Cm abort rebuild Ar drive
400 Abort an in-progress rebuild operation on
401 .Ar drive .
402 It can be resumed with the
403 .Cm start rebuild
404 command.
405 .It Cm locate Ar drive Brq "on | off"
406 Change the state of the external LED associated with
407 .Ar drive .
408 .El
409 .Pp
410 The logical volume management commands include:
411 .Bl -tag -width indent
412 .It Cm cache Ar volume Op Ar setting Oo Ar value Oc Op ...
413 If no
414 .Ar setting
415 arguments are supplied, then the current cache policy for
416 .Ar volume
417 is displayed;
418 otherwise,
419 the cache policy for
420 .Ar volume
421 is modified.
422 One or more
423 .Ar setting
424 arguments may be given.
425 Some settings take an additional
426 .Ar value
427 argument as noted below.
428 The valid settings are:
429 .Bl -tag -width indent
430 .It Cm enable
431 Enable caching for both read and write I/O operations.
432 .It Cm disable
433 Disable caching for both read and write I/O operations.
434 .It Cm reads
435 Enable caching only for read I/O operations.
436 .It Cm writes
437 Enable caching only for write I/O operations.
438 .It Cm write-back
439 Use write-back policy for cached writes.
440 .It Cm write-through
441 Use write-through policy for cached writes.
442 .It Cm read-ahead Ar value
443 Set the read ahead policy for cached reads.
444 The
445 .Ar value
446 argument can be set to either
447 .Dq none ,
448 .Dq adaptive ,
449 or
450 .Dq always .
451 .It Cm bad-bbu-write-cache Ar value
452 Control the behavior of I/O write caching if the battery is dead or
453 missing.
454 The
455 .Ar value
456 argument can be set to either
457 .Dq disable
458 or
459 .Dq enable .
460 In general this setting should be left disabled to avoid data loss when
461 the system loses power.
462 .It Cm write-cache Ar value
463 Control the write caches on the physical drives backing
464 .Ar volume .
465 The
466 .Ar value
467 argument can be set to either
468 .Dq disable ,
469 .Dq enable ,
470 or
471 .Dq default .
472 .Pp
473 In general this setting should be left disabled to avoid data loss when the
474 physical drives lose power.
475 The battery backup of the RAID controller does not save data in the write
476 caches of the physical drives.
477 .El
478 .It Cm name Ar volume Ar name
479 Sets the name of
480 .Ar volume
481 to
482 .Ar name .
483 .It Cm volume progress Ar volume
484 Report the current progress and estimated completion time of volume operations
485 such as consistency checks and initializations.
486 .El
487 .Pp
488 The configuration commands include:
489 .Bl -tag -width indent
490 .It Cm clear
491 Delete the entire configuration including all volumes, arrays, and spares.
492 .It Xo Cm create Ar type
493 .Op Fl v
494 .Op Fl s Ar stripe_size
495 .Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
496 .Op Ar drive Ns Op \&, Ns Ar drive Ns Op ",..."
497 .Xc
498 Create a new volume.
499 The
500 .Ar type
501 specifies the type of volume to create.
502 Currently supported types include:
503 .Bl -tag -width indent
504 .It Cm jbod
505 Creates a RAID0 volume for each drive specified.
506 Each drive must be specified as a separate argument.
507 .It Cm raid0
508 Creates one RAID0 volume spanning the drives listed in the single drive list.
509 .It Cm raid1
510 Creates one RAID1 volume spanning the drives listed in the single drive list.
511 .It Cm raid5
512 Creates one RAID5 volume spanning the drives listed in the single drive list.
513 .It Cm raid6
514 Creates one RAID6 volume spanning the drives listed in the single drive list.
515 .It Cm raid10
516 Creates one RAID10 volume spanning multiple RAID1 arrays.
517 The drives for each RAID1 array are specified as a single drive list.
518 .It Cm raid50
519 Creates one RAID50 volume spanning multiple RAID5 arrays.
520 The drives for each RAID5 array are specified as a single drive list.
521 .It Cm raid60
522 Creates one RAID60 volume spanning multiple RAID6 arrays.
523 The drives for each RAID6 array are specified as a single drive list.
524 .It Cm concat
525 Creates a single volume by concatenating all of the drives in the single drive
526 list.
527 .El
528 .Pp
529 .Sy Note :
530 Not all volume types are supported by all controllers.
531 .Pp
532 If the
533 .Fl v
534 flag is specified after
535 .Ar type ,
536 then more verbose output will be enabled.
537 Currently this just provides notification as drives are added to arrays and
538 arrays to volumes when building the configuration.
539 .Pp
540 The
541 .Fl s
542 .Ar stripe_size
543 parameter allows the stripe size of the array to be set.
544 By default a stripe size of 64K is used.
545 Valid values are 512 through 1M, though the MFI firmware may reject some
546 values.
547 .It Cm delete Ar volume
548 Delete the volume
549 .Ar volume .
550 .It Cm add Ar drive Op Ar volume
551 Mark
552 .Ar drive
553 as a hot spare.
554 .Ar Drive
555 must be in the unconfigured good state.
556 If
557 .Ar volume
558 is specified,
559 then the hot spare will be dedicated to arrays backing that volume.
560 Otherwise,
561 .Ar drive
562 will be used as a global hot spare backing all arrays for this controller.
563 Note that
564 .Ar drive
565 must be as large as the smallest drive in all of the arrays it is going to
566 back.
567 .It Cm remove Ar drive
568 Remove the hot spare
569 .Ar drive
570 from service.
571 It will be placed in the unconfigured good state.
572 .El
573 .Pp
574 The controller management commands include:
575 .Bl -tag -width indent
576 .It Cm patrol Ar command Op Ar interval Op Ar start
577 Set the patrol read operation mode.
578 The
579 .Ar command
580 argument can be one of the following values:
581 .Bl -tag -width indent
582 .It Cm disable
583 Disable patrol reads.
584 .It Cm auto
585 Enable periodic patrol reads initiated by the firmware.
586 The optional
587 .Ar interval
588 argument specifies the interval in seconds between patrol reads.
589 If patrol reads should be run continuously,
590 then
591 .Ar interval
592 should consist of the word
593 .Dq continuously .
594 The optional
595 .Ar start
596 argument specifies a non-negative, relative start time for the next patrol read.
597 If an interval or start time is not specified,
598 then the existing setting will be used.
599 .It Cm manual
600 Enable manual patrol reads that are only initiated by the user.
601 .El
602 .It Cm start patrol
603 Start a patrol read operation.
604 .It Cm stop patrol
605 Stop a currently running patrol read operation.
606 .It Cm foreign scan
607 Scan for foreign configurations and display the number found.
608 The
609 .Ar config
610 argument for the commands below takes the form of a number from 0 to the total
611 configurations found.
612 .It Cm foreign clear Op config
613 Clear the specified foreign
614 .Ar config
615 or all if no
616 .Ar config
617 argument is provided.
618 .It Cm foreign diag Op config
619 Display a diagnostic display of the specified foreign
620 .Ar config
621 or all if no
622 .Ar config
623 argument is provided.
624 .It Cm foreign preview Op config
625 Preview the specified foreign
626 .Ar config
627 after import or all if no
628 .Ar config
629 argument is provided.
630 .It Cm foreign import Op config
631 Import the specified foreign
632 .Ar config
633 or all if no
634 .Ar config
635 argument is provided.
636 .It Cm flash Ar file
637 Updates the flash on the controller with the firmware stored in
638 .Ar file .
639 A reboot is required for the new firmware to take effect.
640 .It Cm start learn
641 Start a battery relearn.
642 Note that this seems to always result in the battery being completely drained,
643 regardless of the BBU mode.
644 In particular, the controller write cache will be disabled during the relearn
645 even if transparent learning mode is enabled.
646 .It Cm bbu Ar setting Ar value
647 Update battery backup unit (BBU) properties related to battery relearning.
648 The following settings are configurable:
649 .Bl -tag -width indent
650 .It Cm learn-delay
651 Add a delay to the next scheduled battery relearn event.
652 This setting is given in hours and must lie in the range of 0 to 255.
653 .It Cm autolearn-mode
654 Enable or disable automatic periodic battery relearning.
655 The setting may be set to
656 .Dq enable
657 or
658 .Dq disable
659 to respectively enable or disable the relearn cycle.
660 Alternatively, a mode of 0, 1 or 2 may be given.
661 Mode 0 enables periodic relearning, mode 1 disables it, and mode 2 disables
662 it and logs a warning to the event log when it detects that a battery relearn
663 should be performed.
664 .It Cm bbu-mode
665 Set the BBU's mode of operation.
666 This setting is not supported by all BBUs.
667 Where it is supported, the possible values are the integers between 1 and 5
668 inclusive.
669 Modes 1, 2 and 3 enable a transparent learn cycle, whereas modes 4 and 5 do not.
670 The BBU's data retention time is greater when transparent learning is not used.
671 .El
672 .It Cm ctrlprop Ar rebuild Op Ar rate
673 With no arguments display the rate of rebuild (percentage)a for volumes.
674 With an integer argument (0-100), set that value as the new rebuild rate for volumes.
675 .It Cm ctrlprop Ar alarm Op Ar 0/1
676 With no arguments display the current alarm enable/disable status.
677 With a 0, disable alarms.
678 With a 1, enable alarms.
679 .El
680 .Sh EXAMPLES
681 Configure the cache for volume mfid0 to cache only writes:
682 .Pp
683 .Dl Nm Cm cache mfid0 writes
684 .Dl Nm Cm cache mfid0 write-back
685 .Pp
686 Create a RAID5 array spanning the first four disks in the second enclosure:
687 .Pp
688 .Dl Nm Cm create raid5 e1:s0,e1:s1,e1:s2,e1:s4
689 .Pp
690 Configure the first three disks on a controller as JBOD:
691 .Pp
692 .Dl Nm Cm create jbod 0 1 2
693 .Pp
694 Create a RAID10 volume that spans two arrays each of which contains two disks
695 from two different enclosures:
696 .Pp
697 .Dl Nm Cm create raid10 e1:s0,e1:s1 e2:s0,e2:s1
698 .Pp
699 Add drive with the device ID of 4 as a global hot spare:
700 .Pp
701 .Dl Nm Cm add 4
702 .Pp
703 Add the drive in slot 2 in the main chassis as a hot spare for volume mfid0:
704 .Pp
705 .Dl Nm Cm add s2 mfid0
706 .Pp
707 Reconfigure a disk as a SYSPD block device with no RAID
708 .Pp
709 .Dl Nm Cm syspd 0
710 .Pp
711 Configure the adapter to run periodic patrol reads once a week with the first
712 patrol read starting in 5 minutes:
713 .Pp
714 .Dl Nm Cm patrol auto 604800 300
715 .Pp
716 Display the second detected foreign configuration:
717 .Pp
718 .Dl Nm Cm show foreign 1
719 .Pp
720 Set the current rebuild rate for volumes to 40%:
721 .Dl Nm Cm ctrlprop rebuild 40
722 .Sh SEE ALSO
723 .Xr mfi 4
724 .Sh HISTORY
725 The
726 .Nm
727 utility first appeared in
728 .Fx 8.0 .