]> CyberLeo.Net >> Repos - FreeBSD/releng/8.1.git/blob - sbin/ccdconfig/ccdconfig.8
Copy stable/8 to releng/8.1 in preparation for 8.1-RC1.
[FreeBSD/releng/8.1.git] / sbin / ccdconfig / ccdconfig.8
1 .\"     $NetBSD: ccdconfig.8,v 1.1.2.1 1995/11/11 02:43:33 thorpej Exp $
2 .\"
3 .\" Copyright (c) 1995 Jason R. Thorpe.
4 .\" All rights reserved.
5 .\"
6 .\" Redistribution and use in source and binary forms, with or without
7 .\" modification, are permitted provided that the following conditions
8 .\" are met:
9 .\" 1. Redistributions of source code must retain the above copyright
10 .\"    notice, this list of conditions and the following disclaimer.
11 .\" 2. Redistributions in binary form must reproduce the above copyright
12 .\"    notice, this list of conditions and the following disclaimer in the
13 .\"    documentation and/or other materials provided with the distribution.
14 .\" 4. The name of the author may not be used to endorse or promote products
15 .\"    derived from this software without specific prior written permission.
16 .\"
17 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
18 .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
19 .\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
20 .\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
21 .\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
22 .\" BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
23 .\" LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED
24 .\" AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
25 .\" OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
26 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
27 .\" SUCH DAMAGE.
28 .\"
29 .\" $FreeBSD$
30 .\"
31 .Dd July 17, 1995
32 .Dt CCDCONFIG 8
33 .Os
34 .Sh NAME
35 .Nm ccdconfig
36 .Nd configuration utility for the concatenated disk driver
37 .Sh SYNOPSIS
38 .Nm
39 .Op Fl cv
40 .Ar ccd
41 .Ar ileave
42 .Op Ar flags
43 .Ar dev ...
44 .Nm
45 .Fl C
46 .Op Fl v
47 .Op Fl f Ar config_file
48 .Nm
49 .Fl u
50 .Op Fl v
51 .Ar ccd ...
52 .Nm
53 .Fl U
54 .Op Fl v
55 .Op Fl f Ar config_file
56 .Nm
57 .Fl g
58 .Op Ar ccd ...
59 .Sh DESCRIPTION
60 The
61 .Nm
62 utility is used to dynamically configure and unconfigure concatenated disk
63 devices, or ccds.
64 For more information about the ccd, see
65 .Xr ccd 4 .
66 .Pp
67 The options are as follows:
68 .Bl -tag -width indent
69 .It Fl c
70 Configure a ccd.
71 This is the default behavior of
72 .Nm .
73 .It Fl C
74 Configure all ccd devices listed in the ccd configuration file.
75 .It Fl f Ar config_file
76 When configuring or unconfiguring all devices, read the file
77 .Pa config_file
78 instead of the default
79 .Pa /etc/ccd.conf .
80 .It Fl g
81 Dump the current ccd configuration in a format suitable for use as the
82 ccd configuration file.
83 If no arguments are specified, every configured
84 ccd is dumped.
85 Otherwise, the configuration of each listed ccd is dumped.
86 .It Fl u
87 Unconfigure a ccd.
88 .It Fl U
89 Unconfigure all ccd devices listed the ccd configuration file.
90 .It Fl v
91 Cause
92 .Nm
93 to be verbose.
94 .El
95 .Pp
96 A ccd is described on the command line and in the ccd configuration
97 file by the name of the ccd, the interleave factor, the ccd configuration
98 flags, and a list of one or more devices.
99 The flags may be represented
100 as a decimal number, a hexadecimal number, a comma-separated list
101 of strings, or the word
102 .Dq none .
103 The flags are as follows:
104 .Bd -literal -offset indent
105 CCDF_UNIFORM    0x02            Use uniform interleave
106 CCDF_MIRROR     0x04            Support mirroring
107 CCDF_NO_OFFSET  0x08            Do not use an offset
108 CCDF_LINUX      0x0A            Linux md(4) compatibility
109 .Ed
110 .Pp
111 The format in the
112 configuration file appears exactly as if it were entered on the command line.
113 Note that on the command line and in the configuration file, the
114 .Pa flags
115 argument is optional.
116 .Bd -literal -offset indent
117 #
118 # /etc/ccd.conf
119 # Configuration file for concatenated disk devices
120 #
121
122 # ccd           ileave  flags   component devices
123 ccd0            16      none    /dev/da2s1 /dev/da3s1
124 .Ed
125 .Pp
126 The component devices need to name partitions of type
127 .Li FS_BSDFFS
128 (or
129 .Dq 4.2BSD
130 as shown by
131 .Xr disklabel 8 ) .
132 .Pp
133 If you want to use the
134 .Tn Linux
135 .Xr md 4
136 compatibility mode, please be sure
137 to read the notes in
138 .Xr ccd 4 .
139 .Sh FILES
140 .Bl -tag -width /etc/ccd.conf -compact
141 .It Pa /etc/ccd.conf
142 default ccd configuration file
143 .El
144 .Sh EXAMPLES
145 A number of
146 .Nm
147 examples are shown below.
148 The arguments passed
149 to
150 .Nm
151 are exactly the same as you might place in the
152 .Pa /etc/ccd.conf
153 configuration file.
154 The first example creates a 4-disk stripe out of
155 four scsi disk partitions.
156 The stripe uses a 64 sector interleave.
157 The second example is an example of a complex stripe/mirror combination.
158 It reads as a two disk stripe of da4 and da5 which is mirrored
159 to a two disk stripe of da6 and da7.
160 The last example is a simple
161 mirror.
162 The 2nd slice of /dev/da8 is mirrored with the 3rd slice of /dev/da9
163 and assigned to ccd0.
164 .Pp
165 .Bd -literal
166 # ccdconfig ccd0 64 none /dev/da0s1 /dev/da1s1 /dev/da2s1 /dev/da3s1
167 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da4 /dev/da5 /dev/da6 /dev/da7
168 # ccdconfig ccd0 128 CCDF_MIRROR /dev/da8s2 /dev/da9s3
169 .Ed
170 .Pp
171 The following are matching commands in
172 .Tn Linux
173 and
174 .Fx
175 to create a RAID-0 in
176 .Tn Linux
177 and read it from
178 .Fx .
179 .Bd -literal
180 # Create a RAID-0 on Linux:
181 mdadm --create --chunk=32 --level=0 --raid-devices=2 /dev/md0 \\
182    /dev/hda1 /dev/hdb1
183 # Make the RAID-0 just created available on FreeBSD:
184 ccdconfig -c /dev/ccd0 32 linux /dev/ad0s1 /dev/ad0s2
185 .Ed
186 .Pp
187 When you create a new ccd disk you generally want to
188 .Xr fdisk 8
189 and
190 .Xr disklabel 8
191 it before doing anything else.
192 Once you create the initial label you can
193 edit it, adding additional partitions.
194 The label itself takes up the first
195 16 sectors of the ccd disk.
196 If all you are doing is creating file systems
197 with newfs, you do not have to worry about this as newfs will skip the
198 label area.
199 However, if you intend to
200 .Xr dd 1
201 to or from a ccd partition it is usually a good idea to construct the
202 partition such that it does not overlap the label area.
203 For example, if
204 you have A ccd disk with 10000 sectors you might create a 'd' partition
205 with offset 16 and size 9984.
206 .Pp
207 .Bd -literal
208 # disklabel ccd0 > /tmp/disklabel.ccd0
209 # disklabel -Rr ccd0 /tmp/disklabel.ccd0
210 # disklabel -e ccd0
211 .Ed
212 .Pp
213 The disklabeling of a ccd disk is usually a one-time affair.
214 If you reboot the machine and reconfigure the ccd disk,
215 the disklabel you
216 had created before will still be there and not require reinitialization.
217 Beware that changing any ccd parameters: interleave, flags, or the
218 device list making up the ccd disk, will usually destroy any prior
219 data on that ccd disk.
220 If this occurs it is usually a good idea to
221 reinitialize the label before [re]constructing your ccd disk.
222 .Sh RECOVERY
223 An error on a ccd disk is usually unrecoverable unless you are using the
224 mirroring option.
225 But mirroring has its own perils: It assumes that
226 both copies of the data at any given sector are the same.
227 This holds true
228 until a write error occurs or until you replace either side of the mirror.
229 This is a poor-man's mirroring implementation.
230 It works well enough that if
231 you begin to get disk errors you should be able to backup the ccd disk,
232 replace the broken hardware, and then regenerate the ccd disk.
233 If you need
234 more than this you should look into external hardware RAID SCSI boxes,
235 RAID controllers (see GENERIC),
236 or software RAID systems such as
237 .Xr geom 8
238 and
239 .Xr vinum 8 .
240 .Sh SEE ALSO
241 .Xr dd 1 ,
242 .Xr ccd 4 ,
243 .Xr disklabel 8 ,
244 .Xr fdisk 8 ,
245 .Xr rc 8 ,
246 .Xr vinum 8
247 .Sh HISTORY
248 The
249 .Nm
250 utility first appeared in
251 .Nx 1.0a .
252 .Sh BUGS
253 The initial disklabel returned by
254 .Xr ccd 4
255 specifies only 3 partitions.
256 One needs to change the number of partitions to 8 using
257 .Dq Nm disklabel Fl e
258 to get the usual
259 .Bx
260 expectations.