]> CyberLeo.Net >> Repos - FreeBSD/releng/9.0.git/blob - sbin/devd/devd.conf.5
Copy stable/9 to releng/9.0 as part of the FreeBSD 9.0-RELEASE release
[FreeBSD/releng/9.0.git] / sbin / devd / devd.conf.5
1 .\"
2 .\" Copyright (c) 2002 M. Warner Losh
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .\" The section on comments was taken from named.conf.5, which has the
28 .\" following copyright:
29 .\" Copyright (c) 1999-2000 by Internet Software Consortium
30 .\"
31 .\" Permission to use, copy, modify, and distribute this software for any
32 .\" purpose with or without fee is hereby granted, provided that the above
33 .\" copyright notice and this permission notice appear in all copies.
34 .\"
35 .\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
36 .\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
37 .\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
38 .\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
39 .\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
40 .\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
41 .\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
42 .\" SOFTWARE.
43 .\"
44 .Dd March 8, 2009
45 .Dt DEVD.CONF 5
46 .Os
47 .Sh NAME
48 .Nm devd.conf
49 .Nd configuration file for
50 .Xr devd 8
51 .Sh DESCRIPTION
52 .Ss General Syntax
53 A
54 .Xr devd 8
55 configuration consists of two general features, statements
56 and comments.
57 All statements end with a semicolon.
58 Many statements can contain substatements, which are also
59 terminated with a semicolon.
60 .Pp
61 The following statements are supported:
62 .Bl -tag -width ".Ic options"
63 .It Ic attach
64 Specifies various matching criteria and actions to perform when
65 a newly attached device matches said criteria.
66 .It Ic detach
67 Specifies various matching criteria and actions to perform when
68 a newly detached device matches said criteria.
69 .It Ic nomatch
70 Specifies various matching criteria and actions to perform when
71 no device driver currently loaded in the kernel claims a (new)
72 device.
73 .It Ic notify
74 Specifies various matching criteria and actions to perform when the kernel
75 sends an event notification to userland.
76 .It Ic options
77 Specifies various options and parameters for the operation of
78 .Xr devd 8 .
79 .El
80 .Pp
81 Statements may occur in any order in the configuration file, and may be
82 repeated as often as required.
83 Further details on the syntax and meaning of each statement and their
84 substatements are explained below.
85 .Pp
86 Each statement, except
87 .Ic options
88 has a priority (an arbitrary number) associated with it, where
89 .Ql 0
90 is defined as the lowest priority.
91 If two statements match the same event, only the action of the statement with
92 highest priority will be executed.
93 In this way generic statements can be overridden for devices or
94 notifications that require special attention.
95 .Pp
96 The general syntax of a statement is:
97 .Bd -literal -offset indent
98 statement priority {
99         substatement "value";
100         ...
101         substatement "value";
102 };
103 .Ed
104 .Ss Sub-statements
105 The following sub-statements are supported within the
106 .Ic options
107 statement.
108 .Bl -tag -width ".Ic directory"
109 .It Ic directory Qq Ar /some/path ;
110 Adds the given directory to the list of directories from which
111 .Xr devd 8
112 will read all files named "*.conf" as further
113 configuration files.
114 Any number of
115 .Ic directory
116 statements can be used.
117 .It Ic pid-file Qq Pa /var/run/devd.pid ;
118 Specifies PID file.
119 .It Ic set Ar regexp-name Qq Ar (some|regexp) ;
120 Creates a regular expression and assigns it to the variable
121 .Ar regexp-name .
122 The variable is available throughout the rest of
123 the configuration file.
124 All regular expressions have an implicit
125 .Ql ^$
126 around them.
127 .El
128 .Pp
129 The following sub-statements are supported within the
130 .Ic attach
131 and
132 .Ic detach
133 statements.
134 .Bl -tag -width ".Ic directory"
135 .It Ic action Qq Ar command ;
136 Command to execute upon a successful match.
137 Example
138 .Dq Li "/etc/pccard_ether $device-name start" .
139 .It Ic class Qq Ar string ;
140 This is shorthand for
141 .Dq Ic match Qo Li class Qc Qq Ar string .
142 .It Ic device-name Qq string ;
143 This is shorthand for
144 .Dq Ic match Qo Li device-name Qc Qq Ar string .
145 This matches a device named
146 .Ar string ,
147 which is allowed to be a regular expression or a variable previously created
148 containing a regular expression.
149 The
150 .Dq Li device-name
151 variable
152 is available for later use with the
153 .Ic action
154 statement.
155 .It Ic match Qo Ar variable Qc Qq Ar value ;
156 Matches the content of
157 .Ar value
158 against
159 .Ar variable ;
160 the content of
161 .Ar value
162 may be a regular expression.
163 Not required during
164 .Ic attach
165 nor
166 .Ic detach
167 events since the
168 .Ic device-name
169 statement takes care of all device matching.
170 For a partial list of variables, see below.
171 .It Ic media-type Qq Ar string ;
172 For network devices,
173 .Ic media-type
174 will match devices that have the given media type.
175 Valid media types are:
176 .Dq Li Ethernet ,
177 .Dq Li Tokenring ,
178 .Dq Li FDDI ,
179 .Dq Li 802.11 ,
180 .Dq Li ATM ,
181 and
182 .Dq Li CARP .
183 .It Ic subdevice Qq Ar string ;
184 This is shorthand for
185 .Dq Ic match Qo Li subdevice Qc Qq Ar string .
186 .El
187 .Pp
188 The following sub-statements are supported within the
189 .Ic nomatch
190 statement.
191 .Bl -tag -width ".Ic directory"
192 .It Ic action Qq Ar command ;
193 Same as above.
194 .It Ic match Qo Ar variable Qc Qq Ar value ;
195 Matches the content of
196 .Ar value
197 against
198 .Ar variable ;
199 the content of
200 .Ar value
201 may be a regular expression.
202 For a partial list of variables, see below.
203 .El
204 .Pp
205 The following sub-statements are supported within the
206 .Ic notify
207 statement.
208 The
209 .Dq Li notify
210 variable is available inside this statement and contains, a value, depending
211 on which system and subsystem that delivered the event.
212 .Bl -tag -width ".Ic directory"
213 .It Ic action Qq Ar command ;
214 Command to execute upon a successful match.
215 Example
216 .Dq Li "/etc/rc.d/power_profile $notify" .
217 .It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
218 Any number of
219 .Ic match
220 statements can exist within a
221 .Ic notify
222 statement;
223 .Ar value
224 can be either a fixed string or a regular expression.
225 Below is a list of available systems, subsystems, and types.
226 .It Ic media-type Qq Ar string ;
227 See above.
228 .El
229 .Ss Variables that can be used with the match statement
230 A partial list of variables and their possible values that can be used together
231 with the
232 .Ic match
233 statement.
234 .Pp
235 .Bl -tag -width ".Li manufacturer" -compact
236 .It Ic Variable
237 .Ic Description
238 .It Li bus
239 Device name of parent bus.
240 .It Li cdev
241 Device node path if one is created by the
242 .Xr devfs 5
243 filesystem.
244 .It Li cisproduct
245 CIS-product.
246 .It Li cisvendor
247 CIS-vendor.
248 .It Li class
249 Device class.
250 .It Li device
251 Device ID.
252 .It Li devclass
253 Device Class (USB)
254 .It Li devsubclass
255 Device Sub-class (USB)
256 .It Li device-name
257 Name of attached/detached device.
258 .It Li endpoints
259 Endpoint count (USB)
260 .It Li function
261 Card functions.
262 .It Li interface
263 Interface ID (USB)
264 .It Li intclass
265 Interface Class (USB)
266 .It Li intprotocol
267 Interface Protocol  (USB)
268 .It Li intsubclass
269 Interface Sub-class (USB)
270 .It Li manufacturer
271 Manufacturer ID (pccard).
272 .It Li mode
273 Peripheral mode (USB)
274 .It Li notify
275 Match the value of the
276 .Dq Li notify
277 variable.
278 .It Li parent
279 Parent device
280 .It Li port
281 Hub port number (USB)
282 .It Li product
283 Product ID (pccard/USB).
284 .It Li release
285 Hardware revision (USB)
286 .It Li sernum
287 Serial Number (USB).
288 .It Li slot
289 Card slot.
290 .It Li subvendor
291 Sub-vendor ID.
292 .It Li subdevice
293 Sub-device ID.
294 .It Li subsystem
295 Matches a subsystem of a system, see below.
296 .It Li system
297 Matches a system type, see below.
298 .It Li type
299 Type of notification, see below.
300 .It Li vendor
301 Vendor ID.
302 .El
303 .Ss Notify matching
304 A partial list of systems, subsystems, and types used within the
305 .Ic notify
306 mechanism.
307 .Pp
308 .Bl -tag -width ".Li coretemp" -compact
309 .It Sy System
310 .It Li ACPI
311 Events related to the ACPI subsystem.
312 .Bl -tag -width ".Sy Subsystem" -compact
313 .It Sy Subsystem
314 .It Li ACAD
315 AC line state ($notify=0x00 is offline, 0x01 is online).
316 .It Li Button
317 Button state ($notify=0x00 is power, 0x01 is sleep).
318 .It Li CMBAT
319 Battery events.
320 .It Li Lid
321 Lid state ($notify=0x00 is closed, 0x01 is open).
322 .It Li Thermal
323 Thermal zone events.
324 .El
325 .Pp
326 .It Li IFNET
327 Events related to the network subsystem.
328 .Bl -tag -width ".Sy Subsystem" -compact
329 .It Sy Subsystem
330 .It Ar interface
331 The
332 .Dq subsystem
333 is the actual name of the network interface on which the event
334 took place.
335 .Bl -tag -width ".Li LINK_DOWN" -compact
336 .It Sy Type
337 .It Li LINK_UP
338 Carrier status changed to UP.
339 .It Li LINK_DOWN
340 Carrier status changed to DOWN.
341 .It Li ATTACH
342 The network interface is attached to the system.
343 .It Li DETACH
344 The network interface is detached from the system.
345 .El
346 .El
347 .It Li DEVFS
348 Events related to the
349 .Xr devfs 5
350 filesystem.
351 .Bl -tag -width ".Sy Subsystem" -compact
352 .It Sy Subsystem
353 .It Li CDEV
354 .Bl -tag -width ".Li DESTROY" -compact
355 .It Sy Type
356 .It Li CREATE
357 The
358 .Xr devfs 5
359 node is created.
360 .It Li DESTROY
361 The
362 .Xr devfs 5
363 node is destroyed.
364 .El
365 .El
366 .It Li USB
367 Events related to the USB subsystem.
368 .Bl -tag -width ".Sy Subsystem" -compact
369 .It Sy Subsystem
370 .It Li DEVICE
371 .Bl -tag -width ".Li DETACH" -compact
372 .It Sy Type
373 .It Li ATTACH
374 USB device is attached to the system.
375 .It Li DETACH
376 USB device is detached from the system.
377 .El
378 .It Li INTERFACE
379 .Bl -tag -width ".Li DETACH" -compact
380 .It Sy Type
381 .It Li ATTACH
382 USB interface is attached to a device.
383 .It Li DETACH
384 USB interface is detached from a device.
385 .El
386 .El
387 .It Li coretemp
388 Events related to the
389 .Xr coretemp 4
390 device.
391 .Bl -tag -width ".Sy Subsystem" -compact
392 .It Sy Subsystem
393 .It Li Thermal
394 Notification that the CPU core has reached critical temperature.
395 .Bl -tag -width ".Ar temperature" -compact
396 .It Sy Type
397 .It Ar temperature
398 String containing the temperature of the core that has become too hot.
399 .El
400 .El
401 .It Li kern
402 Events related to the kernel.
403 .Bl -tag -width ".Sy Subsystem" -compact
404 .It Sy Subsystem
405 .It Li power
406 Information about the state of the system.
407 .Bl -tag -width ".li resume" -compact
408 .It Sy Type
409 .It Li resume
410 Notification that the system has woken from the suspended state.
411 .El
412 .El
413 .El
414 .Pp
415 A link state change to UP on the interface
416 .Dq Li fxp0
417 would result in the following notify event:
418 .Bd -literal -offset indent
419 system=IFNET, subsystem=fxp0, type=LINK_UP
420 .Ed
421 .Pp
422 An AC line state change to
423 .Dq offline
424 would result in the following event:
425 .Bd -literal -offset indent
426 system=ACPI, subsystem=ACAD, notify=0x00
427 .Ed
428 .Ss Comments
429 Comments may appear anywhere that whitespace may appear in a
430 configuration file.
431 To appeal to programmers of all kinds, they can
432 be written in C, C++, or shell/Perl constructs.
433 .Pp
434 C-style comments start with the two characters
435 .Ql /*
436 (slash, star) and end with
437 .Ql */
438 (star, slash).
439 Because they are completely delimited with these characters,
440 they can be used to comment only a portion of a line or to span
441 multiple lines.
442 .Pp
443 C-style comments cannot be nested.
444 For example, the following is
445 not valid because the entire comment ends with the first
446 .Ql */ :
447 .Bd -literal -offset indent
448 /* This is the start of a comment.
449    This is still part of the comment.
450 /* This is an incorrect attempt at nesting a comment. */
451    This is no longer in any comment. */
452 .Ed
453 .Pp
454 C++-style comments start with the two characters
455 .Ql //
456 (slash, slash) and continue to the end of the physical line.
457 They cannot be continued across multiple physical lines; to have
458 one logical comment span multiple lines, each line must use the
459 .Ql //
460 pair.
461 For example:
462 .Bd -literal -offset indent
463 // This is the start of a comment.  The next line
464 // is a new comment, even though it is logically
465 // part of the previous comment.
466 .Ed
467 .Sh FILES
468 .Bl -tag -width ".Pa /etc/devd.conf" -compact
469 .It Pa /etc/devd.conf
470 The
471 .Xr devd 8
472 configuration file.
473 .El
474 .Sh EXAMPLES
475 .Bd -literal
476 #
477 # This will catch link down events on the interfaces fxp0 and ath0
478 #
479 notify 0 {
480         match "system"                  "IFNET";
481         match "subsystem"               "(fxp0|ath0)";
482         match "type"                    "LINK_DOWN";
483         action "logger $subsystem is DOWN";
484 };
485
486 #
487 # Match lid open/close events
488 # These can be combined to a single event, by passing the
489 # value of $notify to the external script.
490 #
491 notify 0 {
492         match "system"                  "ACPI";
493         match "subsystem"               "Lid";
494         match "notify"                  "0x00";
495         action "logger Lid closed, we can sleep now!";
496 };
497
498 notify 0 {
499         match "system"                  "ACPI";
500         match "subsystem"               "Lid";
501         match "notify"                  "0x01";
502         action "logger Lid opened, the sleeper must awaken!";
503 };
504
505 #
506 # Match a USB device type
507 #
508 notify 0 {
509         match "system"                  "USB";
510         match "subsystem"               "INTERFACE";
511         match "type"                    "ATTACH";
512         match "intclass"                "0x0e";
513         action "logger USB video device attached";
514 };
515
516 #
517 # Try to configure ath and wi devices with pccard_ether
518 # as they are attached.
519 #
520 attach 0 {
521         device-name "(ath|wi)[0-9]+";
522         action "/etc/pccard_ether $device-name start";
523 };
524
525 #
526 # Stop ath and wi devices as they are detached from
527 # the system.
528 #
529 detach 0 {
530         device-name "(ath|wi)[0-9]+";
531         action "/etc/pccard_ether $device-name stop";
532 };
533 .Ed
534 .Pp
535 The installed
536 .Pa /etc/devd.conf
537 has many additional examples.
538 .Sh SEE ALSO
539 .Xr coretemp 4 ,
540 .Xr devfs 5 ,
541 .Xr devd 8