]> CyberLeo.Net >> Repos - FreeBSD/releng/9.2.git/blob - usr.sbin/bsnmpd/modules/snmp_bridge/BEGEMOT-BRIDGE-MIB.txt
- Copy stable/9 to releng/9.2 as part of the 9.2-RELEASE cycle.
[FreeBSD/releng/9.2.git] / usr.sbin / bsnmpd / modules / snmp_bridge / BEGEMOT-BRIDGE-MIB.txt
1 --
2 -- Copyright (C) 2006 Shteryana Shopova <syrinx@FreeBSD.org>
3 -- All rights reserved.
4 --
5 -- Redistribution and use in source and binary forms, with or without
6 -- modification, are permitted provided that the following conditions
7 -- are met:
8 -- 1. Redistributions of source code must retain the above copyright
9 --    notice, this list of conditions and the following disclaimer.
10 -- 2. Redistributions in binary form must reproduce the above copyright
11 --    notice, this list of conditions and the following disclaimer in the
12 --    documentation and/or other materials provided with the distribution.
13 --
14 -- THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
15 -- ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
16 -- IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
17 -- ARE DISCLAIMED.  IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
18 -- FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
19 -- DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
20 -- OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
21 -- HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
22 -- LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
23 -- OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
24 -- SUCH DAMAGE.
25 --
26 -- $FreeBSD$
27 --
28
29 BEGEMOT-BRIDGE-MIB DEFINITIONS ::= BEGIN
30
31 IMPORTS
32     MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
33     Counter32, Integer32, TimeTicks, mib-2
34         FROM SNMPv2-SMI
35     TEXTUAL-CONVENTION, MacAddress, TruthValue, RowStatus
36         FROM SNMPv2-TC
37     BridgeId, Timeout
38         FROM BRIDGE-MIB
39     InterfaceIndex FROM IF-MIB
40     begemot
41         FROM BEGEMOT-MIB;
42
43 begemotBridge MODULE-IDENTITY
44     LAST-UPDATED "200708060000Z"
45     ORGANIZATION "Sofia University St. Kliment Ohridski"
46     CONTACT-INFO
47             "           Shteryana Shopova
48
49              Postal:    Faculty of Mathematics and Informatics
50                         5 James Bourchier Blvd.
51                         1164 Sofia
52                         Bulgaria
53
54              Fax:       +359 2 687 180
55
56              E-Mail:    syrinx@FreeBSD.org"
57     DESCRIPTION
58             "The Begemot MIB for managing bridge interfaces."
59     REVISION     "200708060000Z"
60     DESCRIPTION
61              "Third revision adds begemotBridgeBasePortPrivate
62              object."
63     REVISION     "200611210000Z"
64     DESCRIPTION
65              "Second revision adds support for monitoring RSTP
66              specific variables."
67     REVISION     "200607270000Z"
68     DESCRIPTION
69             "Initial revision."
70     ::= { begemot 205 }
71
72 -- ---------------------------------------------------------- --
73 BridgeIfName ::= TEXTUAL-CONVENTION
74     DISPLAY-HINT "16a"
75     STATUS      current
76     DESCRIPTION
77         "Name of a bridge interface."
78     SYNTAX      OCTET STRING (SIZE(1..16))
79
80 BridgeIfNameOrEmpty ::= TEXTUAL-CONVENTION
81     DISPLAY-HINT "16a"
82     STATUS      current
83     DESCRIPTION
84         "Name of a bridge interface."
85     SYNTAX      OCTET STRING (SIZE(0..16))
86
87 BridgePortId ::= TEXTUAL-CONVENTION
88     DISPLAY-HINT "1x.1x"
89     STATUS      current
90     DESCRIPTION
91         "A port identifier that contains a bridge port's STP priority
92         in the first octet and the port number in the second octet."
93     SYNTAX      OCTET STRING (SIZE(2))
94
95 -- ---------------------------------------------------------- --
96 -- subtrees in the Begemot Bridge MIB
97 -- ---------------------------------------------------------- --
98 begemotBridgeNotifications      OBJECT IDENTIFIER ::= { begemotBridge 0 }
99
100 begemotBridgeBase               OBJECT IDENTIFIER ::= { begemotBridge 1 }
101
102 begemotBridgeStp                OBJECT IDENTIFIER ::= { begemotBridge 2 }
103
104 begemotBridgeTp                 OBJECT IDENTIFIER ::= { begemotBridge 3 }
105
106 begemotBridgePf                 OBJECT IDENTIFIER ::= { begemotBridge 4 }
107
108 begemotBridgeConfigObjects      OBJECT IDENTIFIER ::= { begemotBridge 5 }
109
110 -- ---------------------------------------------------------- --
111 -- the base Bridge interface table 
112 -- ---------------------------------------------------------- --
113
114 begemotBridgeBaseTable OBJECT-TYPE
115     SYNTAX      SEQUENCE OF BegemotBridgeBaseEntry
116     MAX-ACCESS  not-accessible
117     STATUS      current
118     DESCRIPTION
119         "A table that contains generic information for each
120         bridge interface on the managed device."
121     ::= { begemotBridgeBase 1 }
122
123 begemotBridgeBaseEntry OBJECT-TYPE
124     SYNTAX      BegemotBridgeBaseEntry
125     MAX-ACCESS  not-accessible
126     STATUS      current
127     DESCRIPTION
128         "A list of information for the bridge interfaces on
129         the managed device."
130     INDEX  { begemotBridgeBaseName }
131     ::= { begemotBridgeBaseTable 1 }
132
133 BegemotBridgeBaseEntry ::= SEQUENCE {
134     begemotBridgeBaseName                       BridgeIfName,
135     begemotBridgeBaseAddress                    MacAddress,
136     begemotBridgeBaseNumPorts                   Integer32,
137     begemotBridgeBaseType                       INTEGER,
138     begemotBridgeBaseStatus                     RowStatus
139 }
140
141 begemotBridgeBaseName OBJECT-TYPE
142     SYNTAX      BridgeIfName
143     MAX-ACCESS  read-only
144     STATUS      current
145     DESCRIPTION
146         "The name of the bridge interface for which this
147         entry contains management information."
148     ::= { begemotBridgeBaseEntry 1 }
149
150 begemotBridgeBaseAddress OBJECT-TYPE
151     SYNTAX      MacAddress
152     MAX-ACCESS  read-only
153     STATUS      current
154     DESCRIPTION
155         "The MAC address of the bridge interface."
156     ::= { begemotBridgeBaseEntry 2 }
157
158 begemotBridgeBaseNumPorts OBJECT-TYPE
159     SYNTAX      Integer32
160     MAX-ACCESS  read-only
161     STATUS      current
162     DESCRIPTION
163         "The number of ports, members of this bridge."
164     ::= { begemotBridgeBaseEntry 3 }
165
166 begemotBridgeBaseType OBJECT-TYPE
167     SYNTAX      INTEGER {
168                     unknown(1),
169                     transparent-only(2),
170                     sourceroute-only(3),
171                     srt(4)
172                 }
173     MAX-ACCESS  read-only
174     STATUS      current
175     DESCRIPTION
176         "Indicates what type of bridging this bridge can
177         perform."
178     ::= { begemotBridgeBaseEntry 4 }
179
180 begemotBridgeBaseStatus OBJECT-TYPE 
181     SYNTAX      RowStatus
182     MAX-ACCESS  read-create
183     STATUS      current
184     DESCRIPTION
185         "Used to create/destroy bridge interfaces on the
186         managed device."
187     ::= { begemotBridgeBaseEntry 5 }
188
189 -- ---------------------------------------------------------- --
190 -- the base Bridge ports table 
191 -- ---------------------------------------------------------- --
192
193 begemotBridgeBasePortTable OBJECT-TYPE
194     SYNTAX      SEQUENCE OF BegemotBridgeBasePortEntry
195     MAX-ACCESS  not-accessible
196     STATUS      current
197     DESCRIPTION
198         "A table containing generic information about ports,
199         members of each bridge interface."
200     ::= { begemotBridgeBase 2 }
201
202 begemotBridgeBasePortEntry OBJECT-TYPE
203     SYNTAX      BegemotBridgeBasePortEntry
204     MAX-ACCESS  not-accessible
205     STATUS      current
206     DESCRIPTION
207         "A list of information about a specific port, member of
208         a bridge interface."
209     INDEX { begemotBridgeBaseName, begemotBridgeBasePortIfIndex }
210     ::= { begemotBridgeBasePortTable 1 }
211
212 BegemotBridgeBasePortEntry  ::= SEQUENCE {
213     begemotBridgeBasePort                       Integer32,
214     begemotBridgeBasePortIfIndex                InterfaceIndex,
215     begemotBridgeBaseSpanEnabled                INTEGER,
216     begemotBridgeBasePortDelayExceededDiscards  Counter32,
217     begemotBridgeBasePortMtuExceededDiscards    Counter32,
218     begemotBridgeBasePortStatus                 RowStatus,
219     begemotBridgeBasePortPrivate                TruthValue
220 }
221
222 begemotBridgeBasePort OBJECT-TYPE
223     SYNTAX      Integer32 (1..65535)
224     MAX-ACCESS  read-only
225     STATUS      current
226     DESCRIPTION
227         "The system interface index of the interface corresponding
228         to this port."
229     ::= { begemotBridgeBasePortEntry 1 }
230
231 begemotBridgeBasePortIfIndex OBJECT-TYPE
232     SYNTAX      InterfaceIndex
233     MAX-ACCESS  read-only
234     STATUS      current
235     DESCRIPTION
236         "The value of the instance of the ifIndex object,
237         defined in IF-MIB, for the interface corresponding
238         to this port."
239     ::= { begemotBridgeBasePortEntry 2 }
240
241 begemotBridgeBaseSpanEnabled OBJECT-TYPE
242     SYNTAX      INTEGER {
243                     enabled(1),
244                     disabled(2)
245                 }
246     MAX-ACCESS  read-write
247     STATUS      current
248     DESCRIPTION
249         "The value of this objects reflects whether the port
250         is a span port on the specified bridge interface."
251     ::= { begemotBridgeBasePortEntry 3 }
252
253 begemotBridgeBasePortDelayExceededDiscards OBJECT-TYPE
254     SYNTAX      Counter32
255     MAX-ACCESS  read-only
256     STATUS      current
257     DESCRIPTION
258         "The number of frames discarded by this port due
259         to excessive transit delay through the bridge."
260     ::= { begemotBridgeBasePortEntry 4 }
261
262 begemotBridgeBasePortMtuExceededDiscards OBJECT-TYPE
263     SYNTAX      Counter32
264     MAX-ACCESS  read-only
265     STATUS      current
266     DESCRIPTION
267         "The number of frames discarded by this port due
268         to an excessive size."
269     ::= { begemotBridgeBasePortEntry 5 }
270
271 begemotBridgeBasePortStatus OBJECT-TYPE
272     SYNTAX      RowStatus
273     MAX-ACCESS  read-create
274     STATUS      current
275     DESCRIPTION
276         "Used to control addition of member ports to or
277         removal of member ports from a specified bridge."
278     ::= { begemotBridgeBasePortEntry 6 }
279
280 begemotBridgeBasePortPrivate OBJECT-TYPE
281     SYNTAX              TruthValue
282     MAX-ACCESS          read-write
283     STATUS              current
284     DESCRIPTION
285         "The value of this objects reflects whether the port
286         has a PRIVATE flag set. A port with this flags set
287         can only communicate with ports not having the
288         PRIVATE flag set."
289     ::= { begemotBridgeBasePortEntry 7 }
290
291 -- ---------------------------------------------------------- --
292 -- the Bridge interface STP table 
293 -- ---------------------------------------------------------- --
294
295 begemotBridgeStpTable OBJECT-TYPE
296     SYNTAX      SEQUENCE OF BegemotBridgeStpEntry
297     MAX-ACCESS  not-accessible
298     STATUS      current
299     DESCRIPTION
300         "A table that contains Spanning Tree Protocol information
301         for each bridge interface on the managed device."
302     ::= { begemotBridgeStp 1 }
303
304 begemotBridgeStpEntry OBJECT-TYPE
305     SYNTAX      BegemotBridgeStpEntry
306     MAX-ACCESS  not-accessible
307     STATUS      current
308     DESCRIPTION
309         "A list of information about the Spanning Tree Protocol
310         operation on a bridge interface."
311     AUGMENTS { begemotBridgeBaseEntry }
312     ::= { begemotBridgeStpTable 1 }
313
314 BegemotBridgeStpEntry ::= SEQUENCE {
315     begemotBridgeStpProtocolSpecification               INTEGER,
316     begemotBridgeStpPriority                            Integer32,
317     begemotBridgeStpTimeSinceTopologyChange             TimeTicks,
318     begemotBridgeStpTopChanges                          Counter32,
319     begemotBridgeStpDesignatedRoot                      BridgeId,
320     begemotBridgeStpRootCost                            Integer32,
321     begemotBridgeStpRootPort                            Integer32,
322     begemotBridgeStpMaxAge                              Timeout,
323     begemotBridgeStpHelloTime                           Timeout,
324     begemotBridgeStpHoldTime                            Integer32,
325     begemotBridgeStpForwardDelay                        Timeout,
326     begemotBridgeStpBridgeMaxAge                        Timeout,
327     begemotBridgeStpBridgeHelloTime                     Timeout,
328     begemotBridgeStpBridgeForwardDelay                  Timeout,
329     begemotBridgeStpVersion                             INTEGER,
330     begemotBridgeStpTxHoldCount                         Integer32
331 }
332
333 begemotBridgeStpProtocolSpecification OBJECT-TYPE
334     SYNTAX      INTEGER {
335                     unknown(1),
336                     decLb100(2),
337                     ieee8021d(3)
338                 }
339     MAX-ACCESS  read-only
340     STATUS      current
341     DESCRIPTION
342         "The Spanning Tree Protocol version being run on the
343         bridge interface. The value 'decLb100(2)' indicates the
344         DEC LANbridge 100 Spanning Tree protocol, 'ieee8021d(3)'
345         indicates the bridge is running IEEE 802.1D STP
346         implementation."
347     ::= { begemotBridgeStpEntry 1 }
348
349 begemotBridgeStpPriority OBJECT-TYPE
350     SYNTAX      Integer32 (0..65535)
351     MAX-ACCESS  read-write
352     STATUS      current
353     DESCRIPTION
354         "The priority value of the bridge interface forming the
355         first two octets of the bridge identifier. Acceptable
356         values are 0-61440, in steps of 4096."
357     ::= { begemotBridgeStpEntry 2 }
358
359 begemotBridgeStpTimeSinceTopologyChange OBJECT-TYPE
360     SYNTAX      TimeTicks
361     UNITS       "centi-seconds"
362     MAX-ACCESS  read-only
363     STATUS      current
364     DESCRIPTION
365         "The time (in hundreds of a second) since a topology change
366         was last detected by this bridge."
367     ::= { begemotBridgeStpEntry 3 }
368
369 begemotBridgeStpTopChanges OBJECT-TYPE
370     SYNTAX      Counter32
371     MAX-ACCESS  read-only
372     STATUS      current
373     DESCRIPTION
374         "The number of times a topology change was detected by the
375         bridge interface since the management entity was initialized
376         or reset."
377     ::= { begemotBridgeStpEntry 4 }
378
379 begemotBridgeStpDesignatedRoot OBJECT-TYPE
380     SYNTAX      BridgeId
381     MAX-ACCESS  read-only
382     STATUS      current
383     DESCRIPTION
384         "The bridge identifier of the root of the spanning tree as
385         calculated by the Spanning Tree Protocol."
386     ::= { begemotBridgeStpEntry 5 }
387
388 begemotBridgeStpRootCost OBJECT-TYPE
389     SYNTAX      Integer32
390     MAX-ACCESS  read-only
391     STATUS      current
392     DESCRIPTION
393         "The cost of the path from this bridge to the root bridge."
394     ::= { begemotBridgeStpEntry 6 }
395
396 begemotBridgeStpRootPort OBJECT-TYPE
397     SYNTAX      Integer32
398     MAX-ACCESS  read-only
399     STATUS      current
400     DESCRIPTION
401         "The port number of the port that offers the lowest
402         cost path from this bridge to the root bridge of
403         the spanning tree. If this bridge is the root bridge,
404         this object shall have a value of zero."
405     ::= { begemotBridgeStpEntry 7 }
406
407 begemotBridgeStpMaxAge OBJECT-TYPE
408     SYNTAX      Timeout
409     UNITS       "centi-seconds"
410     MAX-ACCESS  read-only
411     STATUS      current
412     DESCRIPTION
413         "The maximum age of Spanning Tree Protocol information
414         received from the network on any port, before that
415         information is discarded. This is the actual value that
416         the bridge is currently using."
417     ::= { begemotBridgeStpEntry 8 }
418
419 begemotBridgeStpHelloTime OBJECT-TYPE
420     SYNTAX      Timeout
421     UNITS       "centi-seconds"
422     MAX-ACCESS  read-only
423     STATUS      current
424     DESCRIPTION
425         "The amount of time between transmission of
426         Configuration BPDUs by this bridge on any port,
427         when it is the root of the spanning tree or is
428         trying to become so. This is the actual value that
429         this bridge is currently using."
430     ::= { begemotBridgeStpEntry 9 }
431
432 begemotBridgeStpHoldTime OBJECT-TYPE
433     SYNTAX      Integer32
434     UNITS       "centi-seconds"
435     MAX-ACCESS  read-only
436     STATUS      current
437     DESCRIPTION
438         "This time value determines the interval length
439         during which no more than two Configuration BPDUs
440         shall be transmitted by this node, in units of
441         hundredths of a second."
442     ::= { begemotBridgeStpEntry 10 }
443
444 begemotBridgeStpForwardDelay OBJECT-TYPE
445     SYNTAX      Timeout
446     UNITS       "centi-seconds"
447     MAX-ACCESS  read-only
448     STATUS      current
449     DESCRIPTION
450         "This value, measured in units of hundredths of a second
451         determines how long a port will stay consecutively in the
452         Listening and Learning states before transitioning to
453         Forwarding state.
454         This is the actual value currently used by the bridge
455         as opposed to begemotBridgeStpBridgeForwardDelay, which
456         is the value this and all bridges participating in the
457         spanning tree were to use, if this was the root bridge."
458     ::= { begemotBridgeStpEntry 11 }
459
460 begemotBridgeStpBridgeMaxAge OBJECT-TYPE
461     SYNTAX      Timeout (600..4000)
462     UNITS       "centi-seconds"
463     MAX-ACCESS  read-write
464     STATUS      current
465     DESCRIPTION
466         "The value that all bridges participating in the
467         spanning tree would use for MaxAge if this bridge
468         was the root of the spanning tree."
469     ::= { begemotBridgeStpEntry 12 }
470
471 begemotBridgeStpBridgeHelloTime OBJECT-TYPE
472     SYNTAX      Timeout (100..1000)
473     UNITS       "centi-seconds"
474     MAX-ACCESS  read-write
475     STATUS      current
476     DESCRIPTION
477         "The value that all bridges participating in the
478         spanning tree would use for HelloTime if this
479         bridge was the root of the spanning tree."
480     ::= { begemotBridgeStpEntry 13 }
481
482 begemotBridgeStpBridgeForwardDelay OBJECT-TYPE
483     SYNTAX      Timeout (400..3000)
484     UNITS       "centi-seconds"
485     MAX-ACCESS  read-write
486     STATUS      current
487     DESCRIPTION
488         "The value that all bridges participating in the
489         spanning tree would use for ForwardDelay if this
490         bridge was the root of the spanning tree."
491     ::= { begemotBridgeStpEntry 14 }
492
493 begemotBridgeStpVersion OBJECT-TYPE
494     SYNTAX      INTEGER {
495                     stpCompatible(0),
496                     rstp(2)
497                 }
498     MAX-ACCESS  read-write
499     STATUS      current
500     DESCRIPTION
501         "The version of Spanning Tree Protocol the bridge is
502         currently running.  The value 'stpCompatible(0)'
503         indicates the Spanning Tree Protocol specified in
504         IEEE 802.1D-1998 and 'rstp(2)' indicates the Rapid
505         Spanning Tree Protocol specified in IEEE 802.1w and
506         clause 17 of 802.1D-2004.  The values are directly from
507         the IEEE standard.  New values may be defined as future
508         versions of the protocol become available.
509
510         The value of this object MUST be retained across
511         reinitializations of the management system."
512     DEFVAL      { rstp }
513     ::= { begemotBridgeStpEntry 15 }
514
515 begemotBridgeStpTxHoldCount OBJECT-TYPE
516     SYNTAX      Integer32 (1..10)
517     MAX-ACCESS  read-write
518     STATUS      current
519     DESCRIPTION
520         "The value used by the Port Transmit state machine to limit
521         the maximum transmission rate of BPDUs on the bridge interface.
522
523         The value of this object MUST be retained across
524         reinitializations of the management system."
525     DEFVAL      { 3 }
526     ::= { begemotBridgeStpEntry 16 }
527
528 -- ---------------------------------------------------------- --
529 -- the Bridge STP ports table 
530 -- ---------------------------------------------------------- --
531
532 begemotBridgeStpPortTable OBJECT-TYPE
533     SYNTAX      SEQUENCE OF BegemotBridgeStpPortEntry
534     MAX-ACCESS  not-accessible
535     STATUS      current
536     DESCRIPTION
537         "A table containing Spanning Tree Protocol information
538         about the members of each bridge interface."
539     ::= { begemotBridgeStp 2 }
540
541 begemotBridgeStpPortEntry OBJECT-TYPE
542     SYNTAX      BegemotBridgeStpPortEntry
543     MAX-ACCESS  not-accessible
544     STATUS      current
545     DESCRIPTION
546         "A list of Spanning Tree Protocol information about
547         a specific member of a bridge interface."
548     INDEX  { begemotBridgeBaseName,  begemotBridgeBasePortIfIndex }
549     ::= { begemotBridgeStpPortTable 1 }
550
551 BegemotBridgeStpPortEntry  ::= SEQUENCE {
552     begemotBridgeStpPort                        Integer32,
553     begemotBridgeStpPortPriority                Integer32,
554     begemotBridgeStpPortState                   INTEGER,
555     begemotBridgeStpPortEnable                  INTEGER,
556     begemotBridgeStpPortPathCost                Integer32,
557     begemotBridgeStpPortDesignatedRoot          BridgeId,
558     begemotBridgeStpPortDesignatedCost          Integer32,
559     begemotBridgeStpPortDesignatedBridge        BridgeId,
560     begemotBridgeStpPortDesignatedPort          BridgePortId,
561     begemotBridgeStpPortForwardTransitions      Counter32
562 }
563
564 begemotBridgeStpPort OBJECT-TYPE
565     SYNTAX      Integer32 (1..65535)
566     MAX-ACCESS  read-only
567     STATUS      current
568     DESCRIPTION
569         "The system interface index of the interface corresponding
570         to this port, for which the management entity has Spanning
571         Tree Protocol information."
572     ::= { begemotBridgeStpPortEntry 1 }
573
574 begemotBridgeStpPortPriority OBJECT-TYPE
575     SYNTAX      Integer32 (0..255)
576     MAX-ACCESS  read-write
577     STATUS      current
578     DESCRIPTION
579         "The STP priority of this port that is contained in the first
580         octet of its Port Identifier. The second octet contains the
581         value of begemotBridgeStpPort."
582     ::= { begemotBridgeStpPortEntry 2 }
583
584 begemotBridgeStpPortState OBJECT-TYPE
585     SYNTAX      INTEGER {
586                     disabled(1),
587                     blocking(2),
588                     listening(3),
589                     learning(4),
590                     forwarding(5),
591                     broken(6)
592                 }
593     MAX-ACCESS  read-only
594     STATUS      current
595     DESCRIPTION
596         "The current state of the port as defined by the operation
597         of the Spanning Tree Protocol. If the Spanning Tree Protocol
598         is administratively disabled on the port, this object shall
599         have value disabled(1). A value of broken(6) does not correspond
600         to any legal state of a port, and if present should indicate
601         error in the operation of either the Spanning Tree Protocol
602         implementation running on the device or the management entity."
603     ::= { begemotBridgeStpPortEntry 3 }
604
605 begemotBridgeStpPortEnable OBJECT-TYPE
606     SYNTAX      INTEGER {
607                     enabled(1),
608                     disabled(2)
609                 }
610     MAX-ACCESS  read-write
611     STATUS      current
612     DESCRIPTION
613         "The administrative Spanning Tree Protocol state of the
614         port - value of enabled(1) indicates that the port is
615         participating in the Spanning Tree Protocol operation."
616     ::= { begemotBridgeStpPortEntry 4 }
617
618 begemotBridgeStpPortPathCost OBJECT-TYPE
619     SYNTAX      Integer32 (1..65535)
620     MAX-ACCESS  read-write
621     STATUS      current
622     DESCRIPTION
623         "The contribution of the path through this port, when the port
624         is the Root Port, to the total cost of the path to the root
625         bridge for this bridge."
626     ::= { begemotBridgeStpPortEntry 5 }
627
628 begemotBridgeStpPortDesignatedRoot OBJECT-TYPE
629     SYNTAX      BridgeId
630     MAX-ACCESS  read-only
631     STATUS      current
632     DESCRIPTION
633         "The unique Bridge Identifier of the bridge recorded as the
634         root in the Root Identifier parameter of Configuration BPDUs
635         transmitted by the Designated Bridge for the LAN to which
636         the port is attached."
637     ::= { begemotBridgeStpPortEntry 6 }
638
639 begemotBridgeStpPortDesignatedCost OBJECT-TYPE
640     SYNTAX      Integer32
641     MAX-ACCESS  read-only
642     STATUS      current
643     DESCRIPTION
644         "For a Designated port, the path cost (equal to the Root
645         Path Cost of the bridge) offered to the LAN to which the
646         port is attached otherwise the cost of the path to the Root
647         offered by the Designated Port on the LAN to which this
648         Port is attached."
649     ::= { begemotBridgeStpPortEntry 7 }
650
651 begemotBridgeStpPortDesignatedBridge OBJECT-TYPE
652     SYNTAX      BridgeId
653     MAX-ACCESS  read-only
654     STATUS      current
655     DESCRIPTION
656         "The unique Bridge Identifier of the bridge to which the
657         port belongs, in the case when the port is a designated
658         port, otherwise the bridge believed to be the Designated
659         Bridge for the LAN to which this port is attached."
660     ::= { begemotBridgeStpPortEntry 8 }
661
662 begemotBridgeStpPortDesignatedPort OBJECT-TYPE
663     SYNTAX      BridgePortId
664     MAX-ACCESS  read-only
665     STATUS      current
666     DESCRIPTION
667         "The Port Identifier of the Bridge port, on the Designated
668         Bridge, through which the Designated Bridge transmits the
669         Configuration Message information stored by this port."
670     ::= { begemotBridgeStpPortEntry 9 }
671
672 begemotBridgeStpPortForwardTransitions OBJECT-TYPE
673     SYNTAX      Counter32
674     MAX-ACCESS  read-only
675     STATUS      current
676     DESCRIPTION
677         "The number of times this port has transitioned
678         from the Learning state to the Forwarding state."
679     ::= { begemotBridgeStpPortEntry 10 }
680
681 -- ---------------------------------------------------------- --
682 -- the Bridge STP extended ports table
683 -- ---------------------------------------------------------- --
684
685 begemotBridgeStpExtPortTable OBJECT-TYPE
686     SYNTAX      SEQUENCE OF BegemotBridgeStpExtPortEntry
687     MAX-ACCESS  not-accessible
688     STATUS      current
689     DESCRIPTION
690         "A table that contains port-specific Rapid Spanning Tree
691         information for the bridge interface members."
692     ::= { begemotBridgeStp 3 }
693
694 begemotBridgeStpExtPortEntry OBJECT-TYPE
695     SYNTAX      BegemotBridgeStpExtPortEntry
696     MAX-ACCESS  not-accessible
697     STATUS      current
698     DESCRIPTION
699         "A list of Rapid Spanning Tree information maintained by
700         each bridge interface member."
701     AUGMENTS    { begemotBridgeStpPortEntry }
702     ::= { begemotBridgeStpExtPortTable 1 }
703
704 BegemotBridgeStpExtPortEntry ::= SEQUENCE {
705     begemotBridgeStpPortProtocolMigration       TruthValue,
706     begemotBridgeStpPortAdminEdgePort           TruthValue,
707     begemotBridgeStpPortOperEdgePort            TruthValue,
708     begemotBridgeStpPortAdminPointToPoint       INTEGER,
709     begemotBridgeStpPortOperPointToPoint        TruthValue,
710     begemotBridgeStpPortAdminPathCost           Integer32
711 }
712
713 begemotBridgeStpPortProtocolMigration OBJECT-TYPE
714     SYNTAX      TruthValue
715     MAX-ACCESS  read-write
716     STATUS      current
717     DESCRIPTION
718         "When operating in RSTP (version 2) mode, writing true(1)
719         to this object forces this port to transmit RSTP BPDUs.
720         Any other operation on this object has no effect and
721         it always returns false(2) when read."
722     ::= { begemotBridgeStpExtPortEntry 1 }
723
724 begemotBridgeStpPortAdminEdgePort OBJECT-TYPE
725     SYNTAX      TruthValue
726     MAX-ACCESS  read-write
727     STATUS      current
728     DESCRIPTION
729         "The administrative value of the Edge Port parameter. A
730         value of true(1) indicates that this port should be
731         assumed as an edge-port, and a value of false(2) indicates
732         that this port should be assumed as a non-edge-port.
733         Setting this object will also cause the corresponding
734         instance of begemotBridgeStpPortOperEdgePort to change to
735         the same value.  Note that even when this object's value
736         is true, the value of the corresponding instance of
737         begemotBridgeStpPortOperEdgePort can be false if a BPDU
738         has been received.
739
740         The value of this object MUST be retained across
741         reinitializations of the management system."
742     ::= { begemotBridgeStpExtPortEntry 2 }
743
744 begemotBridgeStpPortOperEdgePort OBJECT-TYPE
745     SYNTAX      TruthValue
746     MAX-ACCESS  read-only
747     STATUS      current
748     DESCRIPTION
749         "The operational value of the Edge Port parameter. The
750         object is initialized to the value of the corresponding
751         instance of begemotBridgeStpPortAdminEdgePort. When the
752         corresponding instance of begemotBridgeStpPortAdminEdgePort
753         is set, this object will be changed as well. This object
754         will also be changed to false on reception of a BPDU."
755     ::= { begemotBridgeStpExtPortEntry 3 }
756
757 begemotBridgeStpPortAdminPointToPoint OBJECT-TYPE
758     SYNTAX      INTEGER {
759                     forceTrue(0),
760                     forceFalse(1),
761                     auto(2)
762                 }
763     MAX-ACCESS  read-write
764     STATUS      current
765     DESCRIPTION
766         "The administrative point-to-point status of the LAN segment
767         attached to this port, using the enumeration values of the
768         IEEE 802.1w clause.  A value of forceTrue(0) indicates
769         that this port should always be treated as if it is
770         connected to a point-to-point link. A value of
771         forceFalse(1) indicates that this port should be treated as
772         having a shared media connection.  A value of auto(2)
773         indicates that this port is considered to have a
774         point-to-point link if it is an Aggregator and all of its
775         members are aggregatable, or if the MAC entity
776         is configured for full duplex operation, either through
777         auto-negotiation or by management means.  Manipulating this
778         object changes the underlying adminPortToPortMAC.
779
780         The value of this object MUST be retained across
781         reinitializations of the management system."
782     ::= { begemotBridgeStpExtPortEntry 4 }
783
784 begemotBridgeStpPortOperPointToPoint OBJECT-TYPE
785     SYNTAX      TruthValue
786     MAX-ACCESS  read-only
787     STATUS      current
788     DESCRIPTION
789         "The operational point-to-point status of the LAN segment
790         attached to this port. It indicates whether a port is
791         considered to have a point-to-point connection.
792         If adminPointToPointMAC is set to auto(2), then the value
793         of operPointToPointMAC is determined in accordance with the
794         specific procedures defined for the MAC entity concerned,
795         as defined in IEEE 802.1w, clause 6.5. The value is
796         determined dynamically; that is, it is re-evaluated whenever
797         the value of adminPointToPointMAC changes, and whenever
798         the specific procedures defined for the MAC entity evaluates
799         a change in its point-to-point status."
800     ::= { begemotBridgeStpExtPortEntry 5 }
801
802 begemotBridgeStpPortAdminPathCost OBJECT-TYPE
803     SYNTAX      Integer32 (0..200000000)
804     MAX-ACCESS  read-write
805     STATUS      current
806     DESCRIPTION
807         "The administratively assigned value for the contribution
808         of this port to the path cost of paths toward the spanning
809         tree root.
810
811         Writing a value of '0' assigns the automatically calculated
812         default Path Cost value to the port. If the default Path
813         Cost is being used, this object returns '0' when read.
814
815         This complements the object begemotBridgeStpPortPathCost or
816         begemotBridgeStpPortPathCost32, which returns the operational
817         value of the path cost.
818
819         The value of this object MUST be retained across
820         reinitializations of the management system."
821     ::= { begemotBridgeStpExtPortEntry 6 }
822
823 -- ---------------------------------------------------------- --
824 -- the Bridge interface Transparent bridging table 
825 -- ---------------------------------------------------------- --
826
827 begemotBridgeTpTable OBJECT-TYPE
828     SYNTAX      SEQUENCE OF BegemotBridgeTpEntry
829     MAX-ACCESS  not-accessible
830     STATUS      current
831     DESCRIPTION
832         "A table that contains information regarding transparent
833         bridging for each bridge interface on the managed device."
834     ::= { begemotBridgeTp 1 }
835
836 begemotBridgeTpEntry OBJECT-TYPE
837     SYNTAX      BegemotBridgeTpEntry
838     MAX-ACCESS  not-accessible
839     STATUS      current
840     DESCRIPTION
841         "A list of information regarding transparent bridging
842         on a bridge interface."
843     AUGMENTS { begemotBridgeBaseEntry }
844     ::= { begemotBridgeTpTable 1 }
845
846 BegemotBridgeTpEntry ::= SEQUENCE {
847     begemotBridgeTpLearnedEntryDiscards         Counter32,
848     begemotBridgeTpAgingTime                    Integer32,
849     begemotBridgeTpMaxAddresses                 Integer32
850 }
851
852 begemotBridgeTpLearnedEntryDiscards OBJECT-TYPE
853     SYNTAX      Counter32
854     MAX-ACCESS  read-only
855     STATUS      current
856     DESCRIPTION
857         "The total number of Forwarding Database entries that would
858         have been learnt, but have been discarded due to Forwarding
859         Address Table having reached it's maximum entries limit."
860     ::= { begemotBridgeTpEntry 1 }
861
862 begemotBridgeTpAgingTime OBJECT-TYPE
863     SYNTAX      Integer32 (10..1000000)
864     UNITS       "seconds"
865     MAX-ACCESS  read-write
866     STATUS      current
867     DESCRIPTION
868         "The timeout period in seconds before aging out
869         dynamically learnt forwarding entries."
870     ::= { begemotBridgeTpEntry 2 }
871
872 begemotBridgeTpMaxAddresses OBJECT-TYPE
873     SYNTAX      Integer32 (1..10000)
874     MAX-ACCESS  read-write
875     STATUS      current
876     DESCRIPTION
877         "The maximum number of entires that this bridge can
878         learn in it's Forwarding Address Table and use for
879         making forwarding decisions."
880     ::= { begemotBridgeTpEntry 3 }
881
882 -- ---------------------------------------------------------- --
883 --  The Forwarding Database for Transparent Bridging interfaces
884 -- ---------------------------------------------------------- --
885
886 begemotBridgeTpFdbTable OBJECT-TYPE
887     SYNTAX      SEQUENCE OF BegemotBridgeTpFdbEntry
888     MAX-ACCESS  not-accessible
889     STATUS      current
890     DESCRIPTION
891         "A table that contains information about unicast entries
892         for which the bridge interfaces have forwarding and/or
893         filtering information. This information is used by the
894         bridge interfaces to make forwarding decisions."
895     ::= { begemotBridgeTp 2 }
896
897 begemotBridgeTpFdbEntry OBJECT-TYPE
898     SYNTAX      BegemotBridgeTpFdbEntry
899     MAX-ACCESS  not-accessible
900     STATUS      current
901     DESCRIPTION
902         "Information about a specific unicast MAC address
903         for which the bridge interface has some forwarding
904         and/or filtering information."
905     INDEX   { begemotBridgeBaseName, begemotBridgeTpFdbAddress }
906     ::= { begemotBridgeTpFdbTable 1 }
907
908 BegemotBridgeTpFdbEntry ::= SEQUENCE {
909     begemotBridgeTpFdbAddress                   MacAddress,
910     begemotBridgeTpFdbPort                      Integer32,
911     begemotBridgeTpFdbStatus                    INTEGER
912 }
913
914 begemotBridgeTpFdbAddress OBJECT-TYPE
915     SYNTAX      MacAddress
916     MAX-ACCESS  read-only
917     STATUS      current
918     DESCRIPTION
919         "A unicast MAC address for which the bridge has which the
920         bridge interface has some forwarding and/or filtering
921         information."
922     ::= { begemotBridgeTpFdbEntry 1 }
923
924 begemotBridgeTpFdbPort OBJECT-TYPE
925     SYNTAX      Integer32
926     MAX-ACCESS  read-only
927     STATUS      current
928     DESCRIPTION
929         "The port number of the bridge port on which a frame having
930         a source address equal to the value of the corresponding
931         instance of begemotBridgeTpFdbAddress has been seen."
932     ::= { begemotBridgeTpFdbEntry 2 }
933
934 begemotBridgeTpFdbStatus OBJECT-TYPE
935     SYNTAX      INTEGER {
936                     other(1),
937                     invalid(2),
938                     learned(3),
939                     self(4),
940                     mgmt(5)
941                 }
942     MAX-ACCESS  read-only
943     STATUS      current
944     DESCRIPTION
945         "The status of this entry.  The meanings of the
946         values are:
947             other(1) - none of the following.
948             invalid(2) - this entry is no longer valid (e.g.,
949                 it was learned but has since aged out), but has
950                 not yet been flushed from the table.
951             learned(3) - the value of the corresponding instance
952                 of begemotBridgeTpFdbPort was learned, and is being
953                 used.
954             self(4) - the value of the corresponding instance of
955                 begemotBridgeTpFdbAddress represents one of the
956                 bridge's addresses.  The corresponding instance of
957                 begemotBridgeTpFdbPort indicates which of the bridge's
958                 ports has this address.
959             mgmt(5) - the value of the corresponding instance of
960                 begemotBridgeTpFdbAddress has been added to the
961                 bridge's Forwarding Database by some management
962                 means."
963     ::= { begemotBridgeTpFdbEntry 3 }
964
965 -- ---------------------------------------------------------- --
966 --  Ports table for Transparent Bridging interfaces
967 -- ---------------------------------------------------------- --
968
969 begemotBridgeTpPortTable OBJECT-TYPE
970     SYNTAX      SEQUENCE OF BegemotBridgeTpPortEntry
971     MAX-ACCESS  not-accessible
972     STATUS      current
973     DESCRIPTION
974         "A table that contains information about every bridge port,
975         member of a bridge interface, associated with the transparent
976         bridging function of the bridge."
977     ::= { begemotBridgeTp 3 }
978
979 begemotBridgeTpPortEntry OBJECT-TYPE
980     SYNTAX      BegemotBridgeTpPortEntry
981     MAX-ACCESS  not-accessible
982     STATUS      current
983     DESCRIPTION
984         "A list of information about every bridge port, member of a
985         bridge interface, associated with the bridge's transparent
986         bridging function."
987     INDEX  { begemotBridgeBaseName,  begemotBridgeBasePortIfIndex }
988     ::= { begemotBridgeTpPortTable 1 }
989
990 BegemotBridgeTpPortEntry  ::= SEQUENCE {
991     begemotBridgeTpPort                         Integer32,
992     begemotBridgeTpPortMaxInfo                  Integer32,
993     begemotBridgeTpPortInFrames                 Counter32,
994     begemotBridgeTpPortOutFrames                Counter32,
995     begemotBridgeTpPortInDiscards               Counter32
996 }
997
998 begemotBridgeTpPort OBJECT-TYPE
999     SYNTAX      Integer32 (1..65535)
1000     MAX-ACCESS  read-only
1001     STATUS      current
1002     DESCRIPTION
1003         "The system interface index of the port for which this entry
1004         contains Transparent bridging management information."
1005     ::= { begemotBridgeTpPortEntry 1 }
1006
1007 begemotBridgeTpPortMaxInfo OBJECT-TYPE
1008     SYNTAX      Integer32
1009     UNITS       "bytes"
1010     MAX-ACCESS  read-only
1011     STATUS      current
1012     DESCRIPTION
1013         "The maximum size of the INFO (non-MAC) field that this port
1014         will receive or transmit."
1015     ::= { begemotBridgeTpPortEntry 2 }
1016
1017 begemotBridgeTpPortInFrames OBJECT-TYPE
1018     SYNTAX      Counter32
1019     UNITS       "frames"
1020     MAX-ACCESS  read-only
1021     STATUS      current
1022     DESCRIPTION
1023         "The number of frames that have been received by this
1024         port from its segment.  Note that a frame received on the
1025         interface corresponding to this port is only counted by
1026         this object if and only if it is for a protocol being
1027         processed by the local bridging function, including
1028         bridge management frames."
1029     ::= { begemotBridgeTpPortEntry 3 }
1030
1031 begemotBridgeTpPortOutFrames OBJECT-TYPE
1032     SYNTAX      Counter32
1033     UNITS       "frames"
1034     MAX-ACCESS  read-only
1035     STATUS      current
1036     DESCRIPTION
1037         "The number of frames that have been transmitted by this
1038         port to its segment.  Note that a frame transmitted on
1039         the interface corresponding to this port is only counted
1040         by this object if and only if it is for a protocol being
1041         processed by the local bridging function, including
1042         bridge management frames."
1043     ::= { begemotBridgeTpPortEntry 4 }
1044
1045 begemotBridgeTpPortInDiscards OBJECT-TYPE
1046     SYNTAX      Counter32
1047     UNITS       "frames"
1048     MAX-ACCESS  read-only
1049     STATUS      current
1050     DESCRIPTION
1051         "Count of received valid frames that were discarded
1052         (i.e., filtered) by the Forwarding Process."
1053     ::= { begemotBridgeTpPortEntry  5 }
1054
1055 -- ---------------------------------------------------------- --
1056 -- the begemotBridgePf objects
1057 -- ---------------------------------------------------------- --
1058
1059 begemotBridgePfilStatus OBJECT-TYPE
1060     SYNTAX      TruthValue
1061     MAX-ACCESS  read-write
1062     STATUS      current
1063     DESCRIPTION
1064         "Indicates whether packet filtering by some firewall
1065         package is enabled on the bridge interface."
1066     ::= { begemotBridgePf 1 }
1067
1068 begemotBridgePfilMembers OBJECT-TYPE
1069     SYNTAX      TruthValue
1070     MAX-ACCESS  read-write
1071     STATUS      current
1072     DESCRIPTION
1073         "A value of true(1) indicates that packet filtering is
1074         enabled on both incoming and outgoing bridge member
1075         interfaces."
1076     ::= { begemotBridgePf 2 }
1077
1078 begemotBridgePfilIpOnly OBJECT-TYPE
1079     SYNTAX      TruthValue
1080     MAX-ACCESS  read-write
1081     STATUS      current
1082     DESCRIPTION
1083         "This value controls the handling of non-IP packets which
1084         are not passed on for further processing to a firewall
1085         package. A value of false(0) indicates that all non-IP
1086         Ethernet frames are passed unconditionally."
1087     ::= { begemotBridgePf 3 }
1088
1089 begemotBridgeLayer2PfStatus OBJECT-TYPE
1090     SYNTAX      INTEGER {
1091                     enabled(1),
1092                     disabled(2)
1093                 }
1094     MAX-ACCESS  read-write
1095     STATUS      current
1096     DESCRIPTION
1097         "This value indicates whether layer2 filtering by a
1098         firewall package is enabled for bridge interfaces."
1099     ::= { begemotBridgePf 4 }
1100
1101 -- ---------------------------------------------------------- --
1102 -- the begemotBridgeConfigObjects objects
1103 -- ---------------------------------------------------------- --
1104
1105 begemotBridgeDefaultBridgeIf OBJECT-TYPE
1106
1107     SYNTAX      BridgeIfNameOrEmpty
1108     MAX-ACCESS  read-write
1109     STATUS      current
1110     DESCRIPTION
1111         "The name of the bridge interface that will be managed
1112         via objects in IETF BRIDGE-MIB (RFC4188). If the
1113         object's value is set to an empty string, bridge interfaces
1114         will only be managed via objects in this MIB module."
1115     DEFVAL      { "bridge0" }
1116     ::= { begemotBridgeConfigObjects 1 }
1117
1118 begemotBridgeDataUpdate OBJECT-TYPE
1119
1120     SYNTAX      Timeout (1..300)
1121     UNITS       "seconds"
1122     MAX-ACCESS  read-write
1123     STATUS      current
1124     DESCRIPTION
1125         "The maximum age in seconds of the cached data."
1126     DEFVAL      { 10 }
1127     ::= { begemotBridgeConfigObjects 2 }
1128
1129 begemotBridgeDataPoll OBJECT-TYPE
1130
1131     SYNTAX      Timeout (1..3600)
1132     UNITS       "seconds"
1133     MAX-ACCESS  read-write
1134     STATUS      current
1135     DESCRIPTION
1136         "The polling rate of data when the module is idle."
1137     DEFVAL      { 300 }
1138     ::= { begemotBridgeConfigObjects 3 }
1139
1140 -- ---------------------------------------------------------- --
1141 -- Notifications for the Spanning Tree Protocol
1142 -- ---------------------------------------------------------- --
1143
1144 begemotBridgeNewRoot NOTIFICATION-TYPE
1145     OBJECTS     { begemotBridgeBaseName }
1146     STATUS      current
1147     DESCRIPTION
1148         "The begemotBridgeNewRoot trap indicates that one of the
1149         bridge interfaces on the sending agent's device has
1150         become the new root of the spanning tree topology it is
1151         participating in."
1152     ::= { begemotBridgeNotifications 1 }
1153
1154 begemotBridgeTopologyChange NOTIFICATION-TYPE
1155     OBJECTS     { begemotBridgeBaseName }
1156     STATUS      current
1157     DESCRIPTION
1158         "A begemotBridgeTopologyChange trap is send when a member
1159         port on one of the bridge interfaces, monitored by the agent,
1160         transitions from the Learning state to the Forwarding state,
1161         or from the Forwarding state to the Blocking state. The trap
1162         is not sent if a begemotBridgeNewRoot trap is sent for the
1163         same transition."
1164     ::= { begemotBridgeNotifications 2 }