1 .\"
2 .\" Copyright (c) 1994 James A. Jegers
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
14 .\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
15 .\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
16 .\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
17 .\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
18 .\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
19 .\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
20 .\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
21 .\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
22 .\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
23 .\"
24 .\" $FreeBSD$
25 .\"
26 .Dd July 10, 1995
27 .Dt SPRAY 8
28 .Os
29 .Sh NAME
30 .Nm spray
31 .Nd send many packets to host
32 .Sh SYNOPSIS
33 .Nm
34 .Op Fl c Ar count
35 .Op Fl d Ar delay
36 .Op Fl l Ar length
37 .Ar host
38 .Sh DESCRIPTION
39 The
40 .Nm
41 utility sends multiple RPC packets to
42 .Ar host
43 and records how many of them were correctly received and how long it took.
44 .Pp
45 The options are as follows:
46 .Bl -tag -width indent
47 .It Fl c Ar count
48 Send
49 .Ar count
50 packets.
51 .It Fl d Ar delay
52 Pause
53 .Ar delay
54 microseconds between sending each packet.
55 .It Fl l Ar length
56 Set the length of the packet that holds the RPC call message to
57 .Ar length
58 bytes.
59 Not all values of
60 .Ar length
61 are possible because RPC data is encoded using XDR.
62 The
63 .Nm
64 utility rounds up to the nearest possible value.
65 .El
66 .Pp
67 The
68 .Nm
69 utility is intended for use in network testing, measurement, and management.
70 This command
71 .Em "can be very hard on a network and should be used with caution" .
72 .Sh SEE ALSO
73 .Xr netstat 1 ,