]> CyberLeo.Net >> Repos - FreeBSD/stable/10.git/blob - sbin/devd/devd.conf.5
Copy head (r256279) to stable/10 as part of the 10.0-RELEASE cycle.
[FreeBSD/stable/10.git] / sbin / devd / devd.conf.5
1 .\"
2 .\" Copyright (c) 2002 M. Warner Losh
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .\" The section on comments was taken from named.conf.5, which has the
28 .\" following copyright:
29 .\" Copyright (c) 1999-2000 by Internet Software Consortium
30 .\"
31 .\" Permission to use, copy, modify, and distribute this software for any
32 .\" purpose with or without fee is hereby granted, provided that the above
33 .\" copyright notice and this permission notice appear in all copies.
34 .\"
35 .\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
36 .\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
37 .\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
38 .\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
39 .\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
40 .\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
41 .\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
42 .\" SOFTWARE.
43 .\"
44 .Dd February 22, 2013
45 .Dt DEVD.CONF 5
46 .Os
47 .Sh NAME
48 .Nm devd.conf
49 .Nd configuration file for
50 .Xr devd 8
51 .Sh DESCRIPTION
52 .Ss General Syntax
53 A
54 .Xr devd 8
55 configuration consists of two general features, statements
56 and comments.
57 All statements end with a semicolon.
58 Many statements can contain substatements, which are also
59 terminated with a semicolon.
60 .Pp
61 The following statements are supported:
62 .Bl -tag -width ".Ic options"
63 .It Ic attach
64 Specifies various matching criteria and actions to perform when
65 a newly attached device matches said criteria.
66 .It Ic detach
67 Specifies various matching criteria and actions to perform when
68 a newly detached device matches said criteria.
69 .It Ic nomatch
70 Specifies various matching criteria and actions to perform when
71 no device driver currently loaded in the kernel claims a (new)
72 device.
73 .It Ic notify
74 Specifies various matching criteria and actions to perform when the kernel
75 sends an event notification to userland.
76 .It Ic options
77 Specifies various options and parameters for the operation of
78 .Xr devd 8 .
79 .El
80 .Pp
81 Statements may occur in any order in the configuration file, and may be
82 repeated as often as required.
83 Further details on the syntax and meaning of each statement and their
84 substatements are explained below.
85 .Pp
86 Each statement, except
87 .Ic options
88 has a priority (an arbitrary number) associated with it, where
89 .Ql 0
90 is defined as the lowest priority.
91 If two statements match the same event, only the action of the statement with
92 highest priority will be executed.
93 In this way generic statements can be overridden for devices or
94 notifications that require special attention.
95 .Pp
96 The general syntax of a statement is:
97 .Bd -literal -offset indent
98 statement priority {
99         substatement "value";
100         ...
101         substatement "value";
102 };
103 .Ed
104 .Ss Sub-statements
105 The following sub-statements are supported within the
106 .Ic options
107 statement.
108 .Bl -tag -width ".Ic directory"
109 .It Ic directory Qq Ar /some/path ;
110 Adds the given directory to the list of directories from which
111 .Xr devd 8
112 will read all files named "*.conf" as further
113 configuration files.
114 Any number of
115 .Ic directory
116 statements can be used.
117 .It Ic pid-file Qq Pa /var/run/devd.pid ;
118 Specifies PID file.
119 .It Ic set Ar regexp-name Qq Ar (some|regexp) ;
120 Creates a regular expression and assigns it to the variable
121 .Ar regexp-name .
122 The variable is available throughout the rest of
123 the configuration file.
124 If the string begins with
125 .Ql \&! ,
126 it matches if the regular expression formed by the rest of the string
127 does not match.
128 All regular expressions have an implicit
129 .Ql ^$
130 around them.
131 .El
132 .Pp
133 The following sub-statements are supported within the
134 .Ic attach
135 and
136 .Ic detach
137 statements.
138 .Bl -tag -width ".Ic directory"
139 .It Ic action Qq Ar command ;
140 Command to execute upon a successful match.
141 Example
142 .Dq Li "/etc/pccard_ether $device-name start" .
143 .It Ic class Qq Ar string ;
144 This is shorthand for
145 .Dq Ic match Qo Li class Qc Qq Ar string .
146 .It Ic device-name Qq string ;
147 This is shorthand for
148 .Dq Ic match Qo Li device-name Qc Qq Ar string .
149 This matches a device named
150 .Ar string ,
151 which is allowed to be a regular expression or a variable previously created
152 containing a regular expression.
153 The
154 .Dq Li device-name
155 variable
156 is available for later use with the
157 .Ic action
158 statement.
159 .It Ic match Qo Ar variable Qc Qq Ar value ;
160 Matches the content of
161 .Ar value
162 against
163 .Ar variable ;
164 the content of
165 .Ar value
166 may be a regular expression.
167 Not required during
168 .Ic attach
169 nor
170 .Ic detach
171 events since the
172 .Ic device-name
173 statement takes care of all device matching.
174 For a partial list of variables, see below.
175 .It Ic media-type Qq Ar string ;
176 For network devices,
177 .Ic media-type
178 will match devices that have the given media type.
179 Valid media types are:
180 .Dq Li Ethernet ,
181 .Dq Li Tokenring ,
182 .Dq Li FDDI ,
183 .Dq Li 802.11 ,
184 and
185 .Dq Li ATM .
186 .It Ic subdevice Qq Ar string ;
187 This is shorthand for
188 .Dq Ic match Qo Li subdevice Qc Qq Ar string .
189 .El
190 .Pp
191 The following sub-statements are supported within the
192 .Ic nomatch
193 statement.
194 .Bl -tag -width ".Ic directory"
195 .It Ic action Qq Ar command ;
196 Same as above.
197 .It Ic match Qo Ar variable Qc Qq Ar value ;
198 Matches the content of
199 .Ar value
200 against
201 .Ar variable ;
202 the content of
203 .Ar value
204 may be a regular expression.
205 For a partial list of variables, see below.
206 .El
207 .Pp
208 The following sub-statements are supported within the
209 .Ic notify
210 statement.
211 The
212 .Dq Li notify
213 variable is available inside this statement and contains, a value, depending
214 on which system and subsystem that delivered the event.
215 .Bl -tag -width ".Ic directory"
216 .It Ic action Qq Ar command ;
217 Command to execute upon a successful match.
218 Example
219 .Dq Li "/etc/rc.d/power_profile $notify" .
220 .It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
221 Any number of
222 .Ic match
223 statements can exist within a
224 .Ic notify
225 statement;
226 .Ar value
227 can be either a fixed string or a regular expression.
228 Below is a list of available systems, subsystems, and types.
229 .It Ic media-type Qq Ar string ;
230 See above.
231 .El
232 .Ss Variables that can be used with the match statement
233 A partial list of variables and their possible values that can be used together
234 with the
235 .Ic match
236 statement.
237 .Pp
238 .Bl -tag -width ".Li manufacturer" -compact
239 .It Ic Variable
240 .Ic Description
241 .It Li bus
242 Device name of parent bus.
243 .It Li cdev
244 Device node path if one is created by the
245 .Xr devfs 5
246 filesystem.
247 .It Li cisproduct
248 CIS-product.
249 .It Li cisvendor
250 CIS-vendor.
251 .It Li class
252 Device class.
253 .It Li device
254 Device ID.
255 .It Li devclass
256 Device Class (USB)
257 .It Li devsubclass
258 Device Sub-class (USB)
259 .It Li device-name
260 Name of attached/detached device.
261 .It Li endpoints
262 Endpoint count (USB)
263 .It Li function
264 Card functions.
265 .It Li interface
266 Interface ID (USB)
267 .It Li intclass
268 Interface Class (USB)
269 .It Li intprotocol
270 Interface Protocol  (USB)
271 .It Li intsubclass
272 Interface Sub-class (USB)
273 .It Li manufacturer
274 Manufacturer ID (pccard).
275 .It Li mode
276 Peripheral mode (USB)
277 .It Li notify
278 Match the value of the
279 .Dq Li notify
280 variable.
281 .It Li parent
282 Parent device
283 .It Li port
284 Hub port number (USB)
285 .It Li product
286 Product ID (pccard/USB).
287 .It Li release
288 Hardware revision (USB)
289 .It Li sernum
290 Serial Number (USB).
291 .It Li slot
292 Card slot.
293 .It Li subvendor
294 Sub-vendor ID.
295 .It Li subdevice
296 Sub-device ID.
297 .It Li subsystem
298 Matches a subsystem of a system, see below.
299 .It Li system
300 Matches a system type, see below.
301 .It Li type
302 Type of notification, see below.
303 .It Li vendor
304 Vendor ID.
305 .El
306 .Ss Notify matching
307 A partial list of systems, subsystems, and types used within the
308 .Ic notify
309 mechanism.
310 .Pp
311 .Bl -tag -width ".Li coretemp" -compact
312 .It Sy System
313 .It Li ACPI
314 Events related to the ACPI subsystem.
315 .Bl -tag -width ".Sy Subsystem" -compact
316 .It Sy Subsystem
317 .It Li ACAD
318 AC line state ($notify=0x00 is offline, 0x01 is online).
319 .It Li Button
320 Button state ($notify=0x00 is power, 0x01 is sleep).
321 .It Li CMBAT
322 Battery events.
323 .It Li Lid
324 Lid state ($notify=0x00 is closed, 0x01 is open).
325 .It Li PROCESSOR
326 Processor state/configuration ($notify=0x81 is a change in available Cx states).
327 .It Li Thermal
328 Thermal zone events.
329 .El
330 .Pp
331 .It Li IFNET
332 Events related to the network subsystem.
333 .Bl -tag -width ".Sy Subsystem" -compact
334 .It Sy Subsystem
335 .It Ar interface
336 The
337 .Dq subsystem
338 is the actual name of the network interface on which the event
339 took place.
340 .Bl -tag -width ".Li LINK_DOWN" -compact
341 .It Sy Type
342 .It Li LINK_UP
343 Carrier status changed to UP.
344 .It Li LINK_DOWN
345 Carrier status changed to DOWN.
346 .It Li ATTACH
347 The network interface is attached to the system.
348 .It Li DETACH
349 The network interface is detached from the system.
350 .El
351 .El
352 .Pp
353 .It Li DEVFS
354 Events related to the
355 .Xr devfs 5
356 filesystem.
357 .Bl -tag -width ".Sy Subsystem" -compact
358 .It Sy Subsystem
359 .It Li CDEV
360 .Bl -tag -width ".Li DESTROY" -compact
361 .It Sy Type
362 .It Li CREATE
363 The
364 .Xr devfs 5
365 node is created.
366 .It Li DESTROY
367 The
368 .Xr devfs 5
369 node is destroyed.
370 .El
371 .El
372 .Pp
373 .It Li USB
374 Events related to the USB subsystem.
375 .Bl -tag -width ".Sy Subsystem" -compact
376 .It Sy Subsystem
377 .It Li DEVICE
378 .Bl -tag -width ".Li DETACH" -compact
379 .It Sy Type
380 .It Li ATTACH
381 USB device is attached to the system.
382 .It Li DETACH
383 USB device is detached from the system.
384 .El
385 .It Li INTERFACE
386 .Bl -tag -width ".Li DETACH" -compact
387 .It Sy Type
388 .It Li ATTACH
389 USB interface is attached to a device.
390 .It Li DETACH
391 USB interface is detached from a device.
392 .El
393 .El
394 .Pp
395 .It Li coretemp
396 Events related to the
397 .Xr coretemp 4
398 device.
399 .Bl -tag -width ".Sy Subsystem" -compact
400 .It Sy Subsystem
401 .It Li Thermal
402 Notification that the CPU core has reached critical temperature.
403 .Bl -tag -width ".Ar temperature" -compact
404 .It Sy Type
405 .It Ar temperature
406 String containing the temperature of the core that has become too hot.
407 .El
408 .El
409 .Pp
410 .It Li kern
411 Events related to the kernel.
412 .Bl -tag -width ".Sy Subsystem" -compact
413 .It Sy Subsystem
414 .It Li power
415 Information about the state of the system.
416 .Bl -tag -width ".li resume" -compact
417 .It Sy Type
418 .It Li resume
419 Notification that the system has woken from the suspended state.
420 .El
421 .El
422 .El
423 .Pp
424 A link state change to UP on the interface
425 .Dq Li fxp0
426 would result in the following notify event:
427 .Bd -literal -offset indent
428 system=IFNET, subsystem=fxp0, type=LINK_UP
429 .Ed
430 .Pp
431 An AC line state change to
432 .Dq offline
433 would result in the following event:
434 .Bd -literal -offset indent
435 system=ACPI, subsystem=ACAD, notify=0x00
436 .Ed
437 .Ss Comments
438 Comments may appear anywhere that whitespace may appear in a
439 configuration file.
440 To appeal to programmers of all kinds, they can
441 be written in C, C++, or shell/Perl constructs.
442 .Pp
443 C-style comments start with the two characters
444 .Ql /*
445 (slash, star) and end with
446 .Ql */
447 (star, slash).
448 Because they are completely delimited with these characters,
449 they can be used to comment only a portion of a line or to span
450 multiple lines.
451 .Pp
452 C-style comments cannot be nested.
453 For example, the following is
454 not valid because the entire comment ends with the first
455 .Ql */ :
456 .Bd -literal -offset indent
457 /* This is the start of a comment.
458    This is still part of the comment.
459 /* This is an incorrect attempt at nesting a comment. */
460    This is no longer in any comment. */
461 .Ed
462 .Pp
463 C++-style comments start with the two characters
464 .Ql //
465 (slash, slash) and continue to the end of the physical line.
466 They cannot be continued across multiple physical lines; to have
467 one logical comment span multiple lines, each line must use the
468 .Ql //
469 pair.
470 For example:
471 .Bd -literal -offset indent
472 // This is the start of a comment.  The next line
473 // is a new comment, even though it is logically
474 // part of the previous comment.
475 .Ed
476 .Sh FILES
477 .Bl -tag -width ".Pa /etc/devd.conf" -compact
478 .It Pa /etc/devd.conf
479 The
480 .Xr devd 8
481 configuration file.
482 .El
483 .Sh EXAMPLES
484 .Bd -literal
485 #
486 # This will catch link down events on the interfaces fxp0 and ath0
487 #
488 notify 0 {
489         match "system"                  "IFNET";
490         match "subsystem"               "(fxp0|ath0)";
491         match "type"                    "LINK_DOWN";
492         action "logger $subsystem is DOWN";
493 };
494
495 #
496 # Match lid open/close events
497 # These can be combined to a single event, by passing the
498 # value of $notify to the external script.
499 #
500 notify 0 {
501         match "system"                  "ACPI";
502         match "subsystem"               "Lid";
503         match "notify"                  "0x00";
504         action "logger Lid closed, we can sleep now!";
505 };
506
507 notify 0 {
508         match "system"                  "ACPI";
509         match "subsystem"               "Lid";
510         match "notify"                  "0x01";
511         action "logger Lid opened, the sleeper must awaken!";
512 };
513
514 #
515 # Match a USB device type
516 #
517 notify 0 {
518         match "system"                  "USB";
519         match "subsystem"               "INTERFACE";
520         match "type"                    "ATTACH";
521         match "intclass"                "0x0e";
522         action "logger USB video device attached";
523 };
524
525 #
526 # Try to configure ath and wi devices with pccard_ether
527 # as they are attached.
528 #
529 attach 0 {
530         device-name "(ath|wi)[0-9]+";
531         action "/etc/pccard_ether $device-name start";
532 };
533
534 #
535 # Stop ath and wi devices as they are detached from
536 # the system.
537 #
538 detach 0 {
539         device-name "(ath|wi)[0-9]+";
540         action "/etc/pccard_ether $device-name stop";
541 };
542 .Ed
543 .Pp
544 The installed
545 .Pa /etc/devd.conf
546 has many additional examples.
547 .Sh SEE ALSO
548 .Xr coretemp 4 ,
549 .Xr devfs 5 ,
550 .Xr re_format 7 ,
551 .Xr devd 8