]> CyberLeo.Net >> Repos - FreeBSD/stable/10.git/blob - sbin/ggate/ggatec/ggatec.8
MFC r267667:
[FreeBSD/stable/10.git] / sbin / ggate / ggatec / ggatec.8
1 .\" Copyright (c) 2004 Pawel Jakub Dawidek <pjd@FreeBSD.org>
2 .\" All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHORS AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHORS OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .Dd April 2, 2015
28 .Dt GGATEC 8
29 .Os
30 .Sh NAME
31 .Nm ggatec
32 .Nd "GEOM Gate network client and control utility"
33 .Sh SYNOPSIS
34 .Nm
35 .Cm create
36 .Op Fl n
37 .Op Fl v
38 .Op Fl o Cm ro | wo | rw
39 .Op Fl p Ar port
40 .Op Fl q Ar queue_size
41 .Op Fl R Ar rcvbuf
42 .Op Fl S Ar sndbuf
43 .Op Fl s Ar sectorsize
44 .Op Fl t Ar timeout
45 .Op Fl u Ar unit
46 .Ar host
47 .Ar path
48 .Nm
49 .Cm rescue
50 .Op Fl n
51 .Op Fl v
52 .Op Fl o Cm ro | wo | rw
53 .Op Fl p Ar port
54 .Op Fl R Ar rcvbuf
55 .Op Fl S Ar sndbuf
56 .Fl u Ar unit
57 .Ar host
58 .Ar path
59 .Nm
60 .Cm destroy
61 .Op Fl f
62 .Fl u Ar unit
63 .Nm
64 .Cm list
65 .Op Fl v
66 .Op Fl u Ar unit
67 .Sh DESCRIPTION
68 The
69 .Nm
70 utility is a network client for the GEOM Gate class.
71 It is responsible for the creation of
72 .Nm ggate
73 devices and forwarding I/O requests between the
74 .Nm geom_gate.ko
75 kernel module and the
76 .Xr ggated 8
77 network daemon.
78 Available commands:
79 .Bl -tag -width ".Cm destroy"
80 .It Cm create
81 Connect to a
82 .Xr ggated 8
83 daemon on the specified host and create a
84 .Nm ggate
85 provider for the specified remote file or device.
86 .It Cm rescue
87 Create a new connection after the
88 .Nm
89 process has died or been killed.
90 The new connection to the
91 .Xr ggated 8
92 daemon handles pending and future requests.
93 .It Cm destroy
94 Destroy the given
95 .Nm ggate
96 provider.
97 .It Cm list
98 List
99 .Nm ggate
100 providers.
101 .El
102 .Pp
103 Available options:
104 .Bl -tag -width ".Fl s Cm ro | wo | rw"
105 .It Fl f
106 Forcibly destroy
107 .Nm ggate
108 provider (cancels all pending requests).
109 .It Fl n
110 Do not use
111 .Dv TCP_NODELAY
112 option on TCP sockets.
113 .It Fl o Cm ro | wo | rw
114 Specify permission to use when opening the file or device: read-only
115 .Pq Cm ro ,
116 write-only
117 .Pq Cm wo ,
118 or read-write
119 .Pq Cm rw .
120 Default is
121 .Cm rw .
122 .It Fl p Ar port
123 Port to connect to on the remote host.
124 Default is 3080.
125 .It Fl q Ar queue_size
126 Number of pending I/O requests that can be queued before they will
127 start to be canceled.
128 Default is 1024.
129 .It Fl R Ar rcvbuf
130 Size of receive buffer to use.
131 Default is 131072 (128kB).
132 .It Fl S Ar sndbuf
133 Size of send buffer to use.
134 Default is 131072 (128kB).
135 .It Fl s Ar sectorsize
136 Sector size for
137 .Nm ggate
138 provider.
139 If not specified, it is taken from device, or set to 512 bytes for files.
140 .It Fl t Ar timeout
141 Number of seconds to wait before an I/O request will be canceled.
142 Default is 0, which means no timeout.
143 .It Fl u Ar unit
144 Unit number to use.
145 .It Fl v
146 Do not fork, run in foreground and print debug information on standard
147 output.
148 .It Ar host
149 Remote host to connect to.
150 .It Ar path
151 Path to a regular file or device.
152 .El
153 .Sh EXIT STATUS
154 Exit status is 0 on success, or 1 if the command fails.
155 To get details about the failure,
156 .Nm
157 should be called with the
158 .Fl v
159 option.
160 .Sh EXAMPLES
161 Use a CD-ROM device on a remote host.
162 .Bd -literal -offset indent
163 server# cat /etc/gg.exports
164 client RO /dev/acd0
165 server# ggated
166
167 client# ggatec create -o ro server /dev/acd0
168 ggate0
169 client# mount_cd9660 /dev/ggate0 /cdrom
170 .Ed
171 .Sh SEE ALSO
172 .Xr geom 4 ,
173 .Xr ggated 8 ,
174 .Xr ggatel 8 ,
175 .Xr mount_cd9660 8
176 .Sh AUTHORS
177 The
178 .Nm
179 utility as well as this manual page was written by
180 .An Pawel Jakub Dawidek Aq Mt pjd@FreeBSD.org .