]> CyberLeo.Net >> Repos - FreeBSD/FreeBSD.git/blob - sys/contrib/openzfs/man/man8/zinject.8
zfs: merge openzfs/zfs@1f940de07
[FreeBSD/FreeBSD.git] / sys / contrib / openzfs / man / man8 / zinject.8
1 .\"
2 .\" CDDL HEADER START
3 .\"
4 .\" The contents of this file are subject to the terms of the
5 .\" Common Development and Distribution License (the "License").
6 .\" You may not use this file except in compliance with the License.
7 .\"
8 .\" You can obtain a copy of the license at usr/src/OPENSOLARIS.LICENSE
9 .\" or https://opensource.org/licenses/CDDL-1.0.
10 .\" See the License for the specific language governing permissions
11 .\" and limitations under the License.
12 .\"
13 .\" When distributing Covered Code, include this CDDL HEADER in each
14 .\" file and include the License file at usr/src/OPENSOLARIS.LICENSE.
15 .\" If applicable, add the following below this CDDL HEADER, with the
16 .\" fields enclosed by brackets "[]" replaced with your own identifying
17 .\" information: Portions Copyright [yyyy] [name of copyright owner]
18 .\"
19 .\" CDDL HEADER END
20 .\"
21 .\" Copyright 2013 Darik Horn <dajhorn@vanadac.com>. All rights reserved.
22 .\" Copyright (c) 2024, Klara Inc.
23 .\"
24 .\" lint-ok: WARNING: sections out of conventional order: Sh SYNOPSIS
25 .\"
26 .Dd April 4, 2024
27 .Dt ZINJECT 8
28 .Os
29 .
30 .Sh NAME
31 .Nm zinject
32 .Nd ZFS Fault Injector
33 .Sh DESCRIPTION
34 .Nm
35 creates artificial problems in a ZFS pool by simulating data corruption
36 or device failures.
37 This program is dangerous.
38 .
39 .Sh SYNOPSIS
40 .Bl -tag -width Ds
41 .It Xo
42 .Nm zinject
43 .Xc
44 List injection records.
45 .
46 .It Xo
47 .Nm zinject
48 .Fl b Ar objset : Ns Ar object : Ns Ar level : Ns Ar start : Ns Ar end
49 .Op Fl f Ar frequency
50 .Fl amu
51 .Op pool
52 .Xc
53 Force an error into the pool at a bookmark.
54 .
55 .It Xo
56 .Nm zinject
57 .Fl c Ar id Ns | Ns Sy all
58 .Xc
59 Cancel injection records.
60 .
61 .It Xo
62 .Nm zinject
63 .Fl d Ar vdev
64 .Fl A Sy degrade Ns | Ns Sy fault
65 .Ar pool
66 .Xc
67 Force a vdev into the DEGRADED or FAULTED state.
68 .
69 .It Xo
70 .Nm zinject
71 .Fl d Ar vdev
72 .Fl D Ar latency : Ns Ar lanes
73 .Op Fl T Ar read|write
74 .Ar pool
75 .Xc
76 Add an artificial delay to I/O requests on a particular
77 device, such that the requests take a minimum of
78 .Ar latency
79 milliseconds to complete.
80 Each delay has an associated number of
81 .Ar lanes
82 which defines the number of concurrent
83 I/O requests that can be processed.
84 .Pp
85 For example, with a single lane delay of 10 ms
86 .No (\& Ns Fl D Ar 10 : Ns Ar 1 ) ,
87 the device will only be able to service a single I/O request
88 at a time with each request taking 10 ms to complete.
89 So, if only a single request is submitted every 10 ms, the
90 average latency will be 10 ms; but if more than one request
91 is submitted every 10 ms, the average latency will be more
92 than 10 ms.
93 .Pp
94 Similarly, if a delay of 10 ms is specified to have two
95 lanes
96 .No (\& Ns Fl D Ar 10 : Ns Ar 2 ) ,
97 then the device will be able to service
98 two requests at a time, each with a minimum latency of 10 ms.
99 So, if two requests are submitted every 10 ms, then
100 the average latency will be 10 ms; but if more than two
101 requests are submitted every 10 ms, the average latency
102 will be more than 10 ms.
103 .Pp
104 Also note, these delays are additive.
105 So two invocations of
106 .Fl D Ar 10 : Ns Ar 1
107 are roughly equivalent to a single invocation of
108 .Fl D Ar 10 : Ns Ar 2 .
109 This also means, that one can specify multiple
110 lanes with differing target latencies.
111 For example, an invocation of
112 .Fl D Ar 10 : Ns Ar 1
113 followed by
114 .Fl D Ar 25 : Ns Ar 2
115 will create 3 lanes on the device: one lane with a latency
116 of 10 ms and two lanes with a 25 ms latency.
117 .
118 .It Xo
119 .Nm zinject
120 .Fl d Ar vdev
121 .Op Fl e Ar device_error
122 .Op Fl L Ar label_error
123 .Op Fl T Ar failure
124 .Op Fl f Ar frequency
125 .Op Fl F
126 .Ar pool
127 .Xc
128 Force a vdev error.
129 .
130 .It Xo
131 .Nm zinject
132 .Fl i Ar seconds
133 .Ar pool
134 .Xc
135 Add an artificial delay during the future import of a pool.
136 This injector is automatically cleared after the import is finished.
137 .
138 .It Xo
139 .Nm zinject
140 .Fl I
141 .Op Fl s Ar seconds Ns | Ns Fl g Ar txgs
142 .Ar pool
143 .Xc
144 Simulate a hardware failure that fails to honor a cache flush.
145 .
146 .It Xo
147 .Nm zinject
148 .Fl p Ar function
149 .Ar pool
150 .Xc
151 Panic inside the specified function.
152 .
153 .It Xo
154 .Nm zinject
155 .Fl t Sy data
156 .Fl C Ar dvas
157 .Op Fl e Ar device_error
158 .Op Fl f Ar frequency
159 .Op Fl l Ar level
160 .Op Fl r Ar range
161 .Op Fl amq
162 .Ar path
163 .Xc
164 Force an error into the contents of a file.
165 .
166 .It Xo
167 .Nm zinject
168 .Fl t Sy dnode
169 .Fl C Ar dvas
170 .Op Fl e Ar device_error
171 .Op Fl f Ar frequency
172 .Op Fl l Ar level
173 .Op Fl amq
174 .Ar path
175 .Xc
176 Force an error into the metadnode for a file or directory.
177 .
178 .It Xo
179 .Nm zinject
180 .Fl t Ar mos_type
181 .Fl C Ar dvas
182 .Op Fl e Ar device_error
183 .Op Fl f Ar frequency
184 .Op Fl l Ar level
185 .Op Fl r Ar range
186 .Op Fl amqu
187 .Ar pool
188 .Xc
189 Force an error into the MOS of a pool.
190 .El
191 .Sh OPTIONS
192 .Bl -tag -width "-C dvas"
193 .It Fl a
194 Flush the ARC before injection.
195 .It Fl b Ar objset : Ns Ar object : Ns Ar level : Ns Ar start : Ns Ar end
196 Force an error into the pool at this bookmark tuple.
197 Each number is in hexadecimal, and only one block can be specified.
198 .It Fl C Ar dvas
199 Inject the given error only into specific DVAs.
200 The mask should be specified as a list of 0-indexed DVAs separated by commas
201 .No (e.g . Ar 0,2 Ns No ).
202 This option is not applicable to logical data errors such as
203 .Sy decompress
204 and
205 .Sy decrypt .
206 .It Fl d Ar vdev
207 A vdev specified by path or GUID.
208 .It Fl e Ar device_error
209 Specify
210 .Bl -tag -compact -width "decompress"
211 .It Sy checksum
212 for an ECKSUM error,
213 .It Sy decompress
214 for a data decompression error,
215 .It Sy decrypt
216 for a data decryption error,
217 .It Sy corrupt
218 to flip a bit in the data after a read,
219 .It Sy dtl
220 for an ECHILD error,
221 .It Sy io
222 for an EIO error where reopening the device will succeed,
223 .It Sy nxio
224 for an ENXIO error where reopening the device will fail, or
225 .It Sy noop
226 to drop the IO without executing it, and return success.
227 .El
228 .Pp
229 For EIO and ENXIO, the "failed" reads or writes still occur.
230 The probe simply sets the error value reported by the I/O pipeline
231 so it appears the read or write failed.
232 Decryption errors only currently work with file data.
233 .It Fl f Ar frequency
234 Only inject errors a fraction of the time.
235 Expressed as a real number percentage between
236 .Sy 0.0001
237 and
238 .Sy 100 .
239 .It Fl F
240 Fail faster.
241 Do fewer checks.
242 .It Fl f Ar txgs
243 Run for this many transaction groups before reporting failure.
244 .It Fl h
245 Print the usage message.
246 .It Fl l Ar level
247 Inject an error at a particular block level.
248 The default is
249 .Sy 0 .
250 .It Fl L Ar label_error
251 Set the label error region to one of
252 .Sy nvlist ,
253 .Sy pad1 ,
254 .Sy pad2 ,
255 or
256 .Sy uber .
257 .It Fl m
258 Automatically remount the underlying filesystem.
259 .It Fl q
260 Quiet mode.
261 Only print the handler number added.
262 .It Fl r Ar range
263 Inject an error over a particular logical range of an object, which
264 will be translated to the appropriate blkid range according to the
265 object's properties.
266 .It Fl s Ar seconds
267 Run for this many seconds before reporting failure.
268 .It Fl T Ar failure
269 Set the failure type to one of
270 .Sy all ,
271 .Sy ioctl ,
272 .Sy claim ,
273 .Sy free ,
274 .Sy read ,
275 or
276 .Sy write .
277 .It Fl t Ar mos_type
278 Set this to
279 .Bl -tag -compact -width "spacemap"
280 .It Sy mos
281 for any data in the MOS,
282 .It Sy mosdir
283 for an object directory,
284 .It Sy config
285 for the pool configuration,
286 .It Sy bpobj
287 for the block pointer list,
288 .It Sy spacemap
289 for the space map,
290 .It Sy metaslab
291 for the metaslab, or
292 .It Sy errlog
293 for the persistent error log.
294 .El
295 .It Fl u
296 Unload the pool after injection.
297 .El
298 .
299 .Sh ENVIRONMENT VARIABLES
300 .Bl -tag -width "ZF"
301 .It Ev ZFS_HOSTID
302 Run
303 .Nm
304 in debug mode.
305 .El
306 .
307 .Sh SEE ALSO
308 .Xr zfs 8 ,