]> CyberLeo.Net >> Repos - FreeBSD/releng/10.0.git/blob - sbin/shutdown/shutdown.8
- Copy stable/10 (r259064) to releng/10.0 as part of the
[FreeBSD/releng/10.0.git] / sbin / shutdown / shutdown.8
1 .\" Copyright (c) 1988, 1991, 1993
2 .\"     The Regents of the University of California.  All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\" 4. Neither the name of the University nor the names of its contributors
13 .\"    may be used to endorse or promote products derived from this software
14 .\"    without specific prior written permission.
15 .\"
16 .\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
17 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
18 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
19 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
20 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
21 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
22 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
23 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
24 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
25 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
26 .\" SUCH DAMAGE.
27 .\"
28 .\"     @(#)shutdown.8  8.2 (Berkeley) 4/27/95
29 .\" $FreeBSD$
30 .\"
31 .Dd March 19, 2013
32 .Dt SHUTDOWN 8
33 .Os
34 .Sh NAME
35 .Nm shutdown ,
36 .Nm poweroff
37 .Nd "close down the system at a given time"
38 .Sh SYNOPSIS
39 .Nm
40 .Op Fl
41 .Oo
42 .Fl h | Fl p |
43 .Fl r | Fl k
44 .Oc
45 .Oo
46 .Fl o
47 .Op Fl n
48 .Oc
49 .Ar time
50 .Op Ar warning-message ...
51 .Nm poweroff
52 .Sh DESCRIPTION
53 The
54 .Nm
55 utility provides an automated shutdown procedure for super-users
56 to nicely notify users when the system is shutting down,
57 saving them from system administrators, hackers, and gurus, who
58 would otherwise not bother with such niceties.
59 .Pp
60 The following options are available:
61 .Bl -tag -width indent
62 .It Fl h
63 The system is halted at the specified
64 .Ar time .
65 .It Fl p
66 The system is halted and the power is turned off
67 (hardware support required)
68 at the specified
69 .Ar time .
70 .It Fl r
71 The system is rebooted at the specified
72 .Ar time .
73 .It Fl k
74 Kick everybody off.
75 The
76 .Fl k
77 option
78 does not actually halt the system, but leaves the
79 system multi-user with logins disabled (for all but super-user).
80 .It Fl o
81 If one of the
82 .Fl h ,
83 .Fl p
84 or
85 .Fl r
86 options are specified,
87 .Nm
88 will execute
89 .Xr halt 8
90 or
91 .Xr reboot 8
92 instead of sending a signal to
93 .Xr init 8 .
94 .It Fl n
95 If the
96 .Fl o
97 option is specified, prevent the file system cache from being flushed by passing
98 .Fl n
99 to
100 .Xr halt 8
101 or
102 .Xr reboot 8 .
103 This option should probably not be used.
104 .It Ar time
105 .Ar Time
106 is the time at which
107 .Nm
108 will bring the system down and
109 may be the case-insensitive word
110 .Ar now
111 (indicating an immediate shutdown) or
112 a future time in one of two formats:
113 .Ar +number ,
114 or
115 .Ar yymmddhhmm ,
116 where the year, month, and day may be defaulted
117 to the current system values.
118 The first form brings the system down in
119 .Ar number
120 minutes and the second at the absolute time specified.
121 .It Ar warning-message
122 Any other arguments comprise the warning message that is broadcast
123 to users currently logged into the system.
124 .It Fl
125 If
126 .Sq Fl
127 is supplied as an option, the warning message is read from the standard
128 input.
129 .El
130 .Pp
131 At intervals, becoming more frequent as apocalypse approaches
132 and starting at ten hours before shutdown, warning messages are displayed
133 on the terminals of all users logged in.
134 Five minutes before
135 shutdown, or immediately if shutdown is in less than 5 minutes,
136 logins are disabled by creating
137 .Pa /var/run/nologin
138 and copying the
139 warning message there.
140 If this file exists when a user attempts to
141 log in,
142 .Xr login 1
143 prints its contents and exits.
144 The file is
145 removed just before
146 .Nm
147 exits.
148 .Pp
149 At shutdown time a message is written to the system log, containing the
150 time of shutdown, the person who initiated the shutdown and the reason.
151 The corresponding signal is then sent to
152 .Xr init 8
153 to respectively halt, reboot or bring the system down to single-user state
154 (depending on the above options).
155 The time of the shutdown and the warning message
156 are placed in
157 .Pa /var/run/nologin
158 and should be used to
159 inform the users about when the system will be back up
160 and why it is going down (or anything else).
161 .Pp
162 A scheduled shutdown can be canceled by killing the
163 .Nm
164 process (a
165 .Dv SIGTERM
166 should suffice).
167 The
168 .Pa /var/run/nologin
169 file that
170 .Nm
171 created will be removed automatically.
172 .Pp
173 When run without options, the
174 .Nm
175 utility will place the system into single user mode at the
176 .Ar time
177 specified.
178 .Pp
179 Calling
180 .Dq Nm poweroff
181 is equivalent to running:
182 .Bd -literal -offset indent
183 shutdown -p now
184 .Ed
185 .Sh FILES
186 .Bl -tag -width /var/run/nologin -compact
187 .It Pa /var/run/nologin
188 tells
189 .Xr login 1
190 not to let anyone log in
191 .El
192 .Sh EXAMPLES
193 Reboot the system in 30 minutes and display a warning message on the terminals
194 of all users currently logged in:
195 .Pp
196 .Dl # shutdown -r +30 \&"System will reboot\&"
197 .Sh COMPATIBILITY
198 The hours and minutes in the second time format may be separated by
199 a colon (``:'') for backward compatibility.
200 .Sh SEE ALSO
201 .Xr kill 1 ,
202 .Xr login 1 ,
203 .Xr wall 1 ,
204 .Xr nologin 5 ,
205 .Xr halt 8 ,
206 .Xr init 8 ,
207 .Xr reboot 8
208 .Sh HISTORY
209 The
210 .Nm
211 utility appeared in
212 .Bx 4.0 .