1 .\" Copyright (c) 1983, 1991, 1993
2 .\"     The Regents of the University of California.  All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\" 3. All advertising materials mentioning features or use of this software
13 .\"    must display the following acknowledgement:
14 .\"     This product includes software developed by the University of
15 .\"     California, Berkeley and its contributors.
16 .\" 4. Neither the name of the University nor the names of its contributors
17 .\"    may be used to endorse or promote products derived from this software
18 .\"    without specific prior written permission.
19 .\"
20 .\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
21 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
22 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
23 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
24 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
25 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
26 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
27 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
28 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
29 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
30 .\" SUCH DAMAGE.
31 .\"
32 .\"     @(#)remote.5    8.1 (Berkeley) 6/5/93
33 .\" $FreeBSD$
34 .\"
35 .Dd October 20, 2003
36 .Dt REMOTE 5
37 .Os
38 .Sh NAME
39 .Nm remote
40 .Nd remote host description file
41 .Sh DESCRIPTION
42 The systems known by
43 .Xr tip 1
44 and their attributes are stored in an
45 .Tn ASCII
46 file which
47 is structured somewhat like the
48 .Xr termcap 5
49 file.
50 Each line in the file provides a description for a single
51 .Em system .
52 Fields are separated by a colon (``:'').
53 Lines ending in a \e character with an immediately following newline are
54 continued on the next line.
55 .Pp
56 The first entry is the name(s) of the host system.
57 If there is more
58 than one name for a system, the names are separated by vertical bars.
59 After the name of the system comes the fields of the description.
60 A field name followed by an `=' sign indicates a string value.
61 A field name followed by a `#' sign indicates a numeric value.
62 .Pp
63 Entries named ``tip*'' and ``cu*'' are used as default entries by
64 .Xr tip 1 ,
65 and the
66 .Xr cu 1
67 interface to
68 .Nm tip ,
69 as follows.
70 When
71 .Nm tip
72 is invoked with only a phone number, it looks for an entry
73 of the form ``tip300'', where 300 is the data rate with
74 which the connection is to be made.
75 When the
76 .Nm cu
77 interface is used, entries of the form ``cu300'' are used.
78 .Sh CAPABILITIES
79 Capabilities are either strings (str), numbers (num), or boolean
80 flags (bool).
81 A string capability is specified by
82 .Em capability Ns Ar = Ns Em value ;
83 for example, ``dv=/dev/harris''.
84 A numeric capability is specified by
85 .Em capability Ns Ar # Ns Em value ;
86 for example, ``xa#99''.
87 A boolean capability is specified by simply listing the capability.
88 .Bl -tag -width indent
89 .It Cm \&at
90 (str)
91 Auto call unit type.
92 .It Cm \&br
93 (num)
94 The data rate (bits per second) used for communications on the
95 serial port.
96 When a modem is used, the data rate used to communicate
97 with the remote modem may be different than this rate.
98 This is a decimal number.
99 The default rate is 9600 bits per second.
100 .It Cm \&cm
101 (str)
102 An initial connection message to be sent to the remote host.
103 For example, if a host is reached through a port selector, this
104 might be set to the appropriate sequence required to switch to the host.
105 .It Cm \&cu
106 (str)
107 Call unit if making a phone call.
108 Default is the same as the `dv' field.
109 .It Cm \&di
110 (str)
111 Disconnect message sent to the host when a disconnect is requested by
112 the user.
113 .It Cm \&du
114 (bool)
115 This host is on a dial-up line.
116 .It Cm \&dv
117 (str)
118 .Ux
119 device(s) to open to establish a connection.
120 If this file refers to a terminal line,
121 .Xr tip 1
122 attempts to perform an exclusive open on the device to ensure only
123 one user at a time has access to the port.
124 .It Cm \&el
125 (str)
126 Characters marking an end-of-line.
127 The default is
128 .Dv NULL .
129 `~' escapes are only
130 recognized by
131 .Nm tip
132 after one of the characters in `el', or after a carriage-return.
133 .It Cm \&fs
134 (str)
135 Frame size for transfers.
136 The default frame size is equal to
137 .Dv BUFSIZ .
138 .It Cm \&hd
139 (bool)
140 The host uses half-duplex communication, local echo should be performed.
141 .It Cm \&ie
142 (str)
143 Input end-of-file marks.
144 The default is
145 .Dv NULL .
146 .It Cm \&oe
147 (str)
148 Output end-of-file string.
149 The default is
150 .Dv NULL .
151 When
152 .Nm tip
153 is transferring a file, this
154 string is sent at end-of-file.
155 .It Cm \&pa
156 (str)
157 The type of parity to use when sending data
158 to the host.
159 This may be one of ``even'',
160 ``odd'', ``none'', ``zero'' (always set bit 8 to zero),
161 ``one'' (always set bit 8 to 1).
162 The default is even parity.
163 .It Cm \&pn
164 (str)
165 Telephone number(s) for this host.
166 If the telephone number field contains an @ sign,
167 .Nm tip
168 searches the file
169 .Pa /etc/phones
170 file for a list of telephone numbers (see
171 .Xr phones 5 ) .
172 .It Cm \&tc
173 (str)
174 Indicates that the list of capabilities is continued in the named
175 description.
176 This is used primarily to share common capability information.
177 .El
178 .Sh FILES
179 .Bl -tag -width /etc/remote -compact
180 .It Pa /etc/remote
181 The
182 .Nm
183 host description file resides in
184 .Pa /etc .
185 .El
186 .Sh EXAMPLES
187 Here is a short example showing the use of the capability continuation
188 feature.
189 It defines a 56k modem connection on the first serial port at 115200
190 bits per second, no parity using the Hayes command set with standard
191 line editing and end of file characters.
192 The arpavax entry includes everything in the UNIX-57600 entry plus
193 the phone number for arpavax (in this case an @ character so that it
194 is retrieved from the environment).
195 .Bd -literal
196 UNIX-57600:\e
197 :dv=/dev/cuau0:el=^D^U^C^S^Q^O@:oe=^D:du:at=hayes:br#115200:pa=none:
198 arpavax|ax:\e
199 :pn=\e@:tc=UNIX-57600
200 .Ed
201 .Sh SEE ALSO
202 .Xr cu 1 ,
203 .Xr tip 1 ,
204 .Xr phones 5
205 .Sh HISTORY
206 The
207 .Nm
208 file format appeared in
209 .Bx 4.2 .
210 .Sh BUGS
211 The
212 .Xr tip 1
213 utility uses its own notion of the serial ports data rate rather than the
214 system default for a serial port.