]> CyberLeo.Net >> Repos - FreeBSD/releng/7.2.git/blob - sbin/devd/devd.conf.5
Create releng/7.2 from stable/7 in preparation for 7.2-RELEASE.
[FreeBSD/releng/7.2.git] / sbin / devd / devd.conf.5
1 .\"
2 .\" Copyright (c) 2002 M. Warner Losh
3 .\" All rights reserved.
4 .\"
5 .\" Redistribution and use in source and binary forms, with or without
6 .\" modification, are permitted provided that the following conditions
7 .\" are met:
8 .\" 1. Redistributions of source code must retain the above copyright
9 .\"    notice, this list of conditions and the following disclaimer.
10 .\" 2. The name of the author may not be used to endorse or promote products
11 .\"    derived from this software without specific prior written permission.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .\" The section on comments was taken from named.conf.5, which has the
28 .\" following copyright:
29 .\" Copyright (c) 1999-2000 by Internet Software Consortium
30 .\"
31 .\" Permission to use, copy, modify, and distribute this software for any
32 .\" purpose with or without fee is hereby granted, provided that the above
33 .\" copyright notice and this permission notice appear in all copies.
34 .\"
35 .\" THE SOFTWARE IS PROVIDED "AS IS" AND INTERNET SOFTWARE CONSORTIUM DISCLAIMS
36 .\" ALL WARRANTIES WITH REGARD TO THIS SOFTWARE INCLUDING ALL IMPLIED WARRANTIES
37 .\" OF MERCHANTABILITY AND FITNESS. IN NO EVENT SHALL INTERNET SOFTWARE
38 .\" CONSORTIUM BE LIABLE FOR ANY SPECIAL, DIRECT, INDIRECT, OR CONSEQUENTIAL
39 .\" DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE, DATA OR
40 .\" PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER TORTIOUS
41 .\" ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THIS
42 .\" SOFTWARE.
43 .\"
44 .Dd March 8, 2009
45 .Dt DEVD.CONF 5
46 .Os
47 .Sh NAME
48 .Nm devd.conf
49 .Nd configuration file for
50 .Xr devd 8
51 .Sh DESCRIPTION
52 .Ss General Syntax
53 A
54 .Xr devd 8
55 configuration consists of two general features, statements
56 and comments.
57 All statements end with a semicolon.
58 Many statements can contain substatements, which are also
59 terminated with a semicolon.
60 .Pp
61 The following statements are supported:
62 .Bl -tag -width ".Ic options"
63 .It Ic attach
64 Specifies various matching criteria and actions to perform when
65 a newly attached device matches said criteria.
66 .It Ic detach
67 Specifies various matching criteria and actions to perform when
68 a newly detached device matches said criteria.
69 .It Ic nomatch
70 Specifies various matching criteria and actions to perform when
71 no device driver currently loaded in the kernel claims a (new)
72 device.
73 .It Ic notify
74 Specifies various matching criteria and actions to perform when the kernel
75 sends an event notification to userland.
76 .It Ic options
77 Specifies various options and parameters for the operation of
78 .Xr devd 8 .
79 .El
80 .Pp
81 Statements may occur in any order in the configuration file, and may be
82 repeated as often as required.
83 Further details on the syntax and meaning of each statement and their
84 substatements are explained below.
85 .Pp
86 Each statement, except
87 .Ic options
88 has a priority (an arbitrary number) associated with it, where
89 .Ql 0
90 is defined as the lowest priority.
91 If two statements match the same event, only the action of the statement with
92 highest priority will be executed.
93 In this way generic statements can be overridden for devices or
94 notifications that require special attention.
95 .Pp
96 The general syntax of a statement is:
97 .Pp
98 .Bd -literal -offset indent
99 statement priority {
100         substatement "value";
101         ...
102         substatement "value";
103 };
104 .Ed
105 .Ss Sub-statements
106 The following sub-statements are supported within the
107 .Ic options
108 statement.
109 .Bl -tag -width ".Ic directory"
110 .It Ic directory Qq Ar /some/path ;
111 Adds the given directory to the list of directories from which
112 .Xr devd 8
113 will read
114 configuration files.
115 Any number of
116 .Ic directory
117 statements can be used.
118 .It Ic pid-file Qq Pa /var/run/devd.pid ;
119 Specifies PID file.
120 .It Ic set Ar regexp-name Qq Ar (some|regexp) ;
121 Creates a regular expression and assigns it to the variable
122 .Ar regexp-name .
123 The variable is available throughout the rest of
124 the configuration file.
125 All regular expressions have an implicit
126 .Ql ^$
127 around them.
128 .El
129 .Pp
130 The following sub-statements are supported within the
131 .Ic attach
132 and
133 .Ic detach
134 statements.
135 .Bl -tag -width ".Ic directory"
136 .It Ic action Qq Ar command ;
137 Command to execute upon a successful match.
138 Example
139 .Dq Li "/etc/pccard_ether $device-name start" .
140 .It Ic class Qq Ar string ;
141 This is shorthand for
142 .Dq Ic match Qo Li class Qc Qq Ar string .
143 .It Ic device-name Qq string ;
144 This is shorthand for
145 .Dq Ic match Qo Li device-name Qc Qq Ar string .
146 This matches a device named
147 .Ar string ,
148 which is allowed to be a regular expression or a variable previously created
149 containing a regular expression.
150 The
151 .Dq Li device-name
152 variable
153 is available for later use with the
154 .Ic action
155 statement.
156 .It Ic match Qo Ar variable Qc Qq Ar value ;
157 Matches the content of
158 .Ar value
159 against
160 .Ar variable ;
161 the content of
162 .Ar value
163 may be a regular expression.
164 Not required during
165 .Ic attach
166 nor
167 .Ic detach
168 events since the
169 .Ic device-name
170 statement takes care of all device matching.
171 For a partial list of variables, see below.
172 .It Ic media-type Qq Ar string ;
173 For network devices,
174 .Ic media-type
175 will match devices that have the given media type.
176 Valid media types are:
177 .Dq Li Ethernet ,
178 .Dq Li Tokenring ,
179 .Dq Li FDDI ,
180 .Dq Li 802.11 ,
181 .Dq Li ATM ,
182 and
183 .Dq Li CARP .
184 .It Ic subdevice Qq Ar string ;
185 This is shorthand for
186 .Dq Ic match Qo Li subdevice Qc Qq Ar string .
187 .El
188 .Pp
189 The following sub-statements are supported within the
190 .Ic nomatch
191 statement.
192 .Bl -tag -width ".Ic directory"
193 .It Ic action Qq Ar command ;
194 Same as above.
195 .It Ic match Qo Ar variable Qc Qq Ar value ;
196 Matches the content of
197 .Ar value
198 against
199 .Ar variable ;
200 the content of
201 .Ar value
202 may be a regular expression.
203 For a partial list of variables, see below.
204 .El
205 .Pp
206 The following sub-statements are supported within the
207 .Ic notify
208 statement.
209 The
210 .Dq Li notify
211 variable is available inside this statement and contains, a value, depending
212 on which system and subsystem that delivered the event.
213 .Bl -tag -width ".Ic directory"
214 .It Ic action Qq Ar command ;
215 Command to execute upon a successful match.
216 Example
217 .Dq Li "/etc/rc.d/power_profile $notify" .
218 .It Ic match Qo Ar system | subsystem | type | notify Qc Qq Ar value ;
219 Any number of
220 .Ic match
221 statements can exist within a
222 .Ic notify
223 statement;
224 .Ar value
225 can be either a fixed string or a regular expression.
226 Below is a list of available systems, subsystems, and types.
227 .It Ic media-type Qq Ar string ;
228 See above.
229 .El
230 .Ss Variables that can be used with the match statement
231 A partial list of variables and their possible values that can be used together
232 with the
233 .Ic match
234 statement.
235 .Pp
236 .Bl -tag -width ".Li manufacturer" -compact
237 .It Ic Variable
238 .Ic Description
239 .It Li bus
240 Device name of parent bus.
241 .It Li cdev
242 Device node path if one is created by the
243 .Xr devfs 5
244 filesystem.
245 .It Li cisproduct
246 CIS-product.
247 .It Li cisvendor
248 CIS-vendor.
249 .It Li class
250 Device class.
251 .It Li device
252 Device ID.
253 .It Li device-name
254 Name of attached/detached device.
255 .It Li function
256 Card functions.
257 .It Li manufacturer
258 Manufacturer ID (pccard).
259 .It Li notify
260 Match the value of the
261 .Dq Li notify
262 variable.
263 .It Li product
264 Product ID (pccard).
265 .It Li serial
266 Serial Number (USB).
267 .It Li slot
268 Card slot.
269 .It Li subvendor
270 Sub-vendor ID.
271 .It Li subdevice
272 Sub-device ID.
273 .It Li subsystem
274 Matches a subsystem of a system, see below.
275 .It Li system
276 Matches a system type, see below.
277 .It Li type
278 Type of notification, see below.
279 .It Li vendor
280 Vendor ID.
281 .El
282 .Ss Notify matching
283 A partial list of systems, subsystems, and types used within the
284 .Ic notify
285 mechanism.
286 .Pp
287 .Bl -tag -width ".Li coretemp" -compact
288 .It Sy System
289 .It Li ACPI
290 Events related to the ACPI subsystem.
291 .Bl -tag -width ".Sy Subsystem" -compact
292 .It Sy Subsystem
293 .It Li ACAD
294 AC line state ($notify=0x00 is offline, 0x01 is online).
295 .It Li Button
296 Button state ($notify=0x00 is power, 0x01 is sleep).
297 .It Li CMBAT
298 Battery events.
299 .It Li Lid
300 Lid state ($notify=0x00 is closed, 0x01 is open).
301 .It Li Thermal
302 Thermal zone events.
303 .El
304 .Pp
305 .It Li IFNET
306 Events related to the network subsystem.
307 .Bl -tag -width ".Sy Subsystem" -compact
308 .It Sy Subsystem
309 .It Ar interface
310 The
311 .Dq subsystem
312 is the actual name of the network interface on which the event
313 took place.
314 .Bl -tag -width ".Li LINK_DOWN" -compact
315 .It Sy Type
316 .It Li LINK_UP
317 Carrier status changed to UP.
318 .It Li LINK_DOWN
319 Carrier status changed to DOWN.
320 .It Li ATTACH
321 The network interface is attached to the system.
322 .It Li DETACH
323 The network interface is detached from the system.
324 .El
325 .El
326 .It Li DEVFS
327 Events related to the
328 .Xr devfs 5
329 filesystem.
330 .Bl -tag -width ".Sy Subsystem" -compact
331 .It Sy Subsystem
332 .It Li CDEV
333 .Bl -tag -width ".Li DESTROY" -compact
334 .It Sy Type
335 .It Li CREATE
336 The
337 .Xr devfs 5
338 node is created.
339 .It Li DESTROY
340 The
341 .Xr devfs 5
342 node is destroyed.
343 .El
344 .El
345 .It Li coretemp
346 Events related to the
347 .Xr coretemp 4
348 device.
349 .Bl -tag -width ".Sy Subsystem" -compact
350 .It Sy Subsystem
351 .It Li Thermal
352 Notification that the CPU core has reached critical temperature.
353 .Bl -tag -width ".Ar temperature" -compact
354 .It Sy Type
355 .It Ar temperature
356 String containing the temperature of the core that has become too hot.
357 .El
358 .El
359 .It Li kern
360 Events related to the kernel.
361 .Bl -tag -width ".Sy Subsystem" -compact
362 .It Sy Subsystem
363 .It Li power
364 Information about the state of the system.
365 .Bl -tag -width ".li resume" -compact
366 .It Sy Type
367 .It Li resume
368 Notification that the system has woken from the suspended state.
369 .El
370 .El
371 .El
372 .Pp
373 A link state change to UP on the interface
374 .Dq Li fxp0
375 would result in the following notify event:
376 .Bd -literal -offset indent
377 system=IFNET, subsystem=fxp0, type=LINK_UP
378 .Ed
379 .Pp
380 An AC line state change to
381 .Dq offline
382 would result in the following event:
383 .Bd -literal -offset indent
384 system=ACPI, subsystem=ACAD, notify=0x00
385 .Ed
386 .Ss Comments
387 Comments may appear anywhere that whitespace may appear in a
388 configuration file.
389 To appeal to programmers of all kinds, they can
390 be written in C, C++, or shell/Perl constructs.
391 .Pp
392 C-style comments start with the two characters
393 .Ql /*
394 (slash, star) and end with
395 .Ql */
396 (star, slash).
397 Because they are completely delimited with these characters,
398 they can be used to comment only a portion of a line or to span
399 multiple lines.
400 .Pp
401 C-style comments cannot be nested.
402 For example, the following is
403 not valid because the entire comment ends with the first
404 .Ql */ :
405 .Bd -literal -offset indent
406 /* This is the start of a comment.
407    This is still part of the comment.
408 /* This is an incorrect attempt at nesting a comment. */
409    This is no longer in any comment. */
410 .Ed
411 .Pp
412 C++-style comments start with the two characters
413 .Ql //
414 (slash, slash) and continue to the end of the physical line.
415 They cannot be continued across multiple physical lines; to have
416 one logical comment span multiple lines, each line must use the
417 .Ql //
418 pair.
419 For example:
420 .Bd -literal -offset indent
421 // This is the start of a comment.  The next line
422 // is a new comment, even though it is logically
423 // part of the previous comment.
424 .Ed
425 .Sh FILES
426 .Bl -tag -width ".Pa /etc/devd.conf" -compact
427 .It Pa /etc/devd.conf
428 The
429 .Xr devd 8
430 configuration file.
431 .El
432 .Sh EXAMPLES
433 .Bd -literal
434 #
435 # This will catch link down events on the interfaces fxp0 and ath0
436 #
437 notify 0 {
438         match "system"                  "IFNET";
439         match "subsystem"               "(fxp0|ath0)";
440         match "type"                    "LINK_DOWN";
441         action "logger $subsystem is DOWN";
442 };
443
444 #
445 # Match lid open/close events
446 # These can be combined to a single event, by passing the
447 # value of $notify to the external script.
448 #
449 notify 0 {
450         match "system"                  "ACPI";
451         match "subsystem"               "Lid";
452         match "notify"                  "0x00";
453         action "logger Lid closed, we can sleep now!";
454 };
455
456 notify 0 {
457         match "system"                  "ACPI";
458         match "subsystem"               "Lid";
459         match "notify"                  "0x01";
460         action "logger Lid opened, the sleeper must awaken!";
461 };
462
463 #
464 # Try to configure ath and wi devices with pccard_ether
465 # as they are attached.
466 #
467 attach 0 {
468         device-name "(ath|wi)[0-9]+";
469         action "/etc/pccard_ether $device-name start";
470 };
471
472 #
473 # Stop ath and wi devices as they are detached from
474 # the system.
475 #
476 detach 0 {
477         device-name "(ath|wi)[0-9]+";
478         action "/etc/pccard_ether $device-name stop";
479 };
480 .Ed
481 .Pp
482 The installed
483 .Pa /etc/devd.conf
484 has many additional examples.
485 .Sh SEE ALSO
486 .Xr coretemp 4 ,
487 .Xr devfs 5 ,
488 .Xr devd 8