]> CyberLeo.Net >> Repos - FreeBSD/releng/7.2.git/blob - usr.sbin/powerd/powerd.8
Create releng/7.2 from stable/7 in preparation for 7.2-RELEASE.
[FreeBSD/releng/7.2.git] / usr.sbin / powerd / powerd.8
1 .\" Copyright (c) 2005 Nate Lawson
2 .\" All rights reserved.
3 .\"
4 .\" Redistribution and use in source and binary forms, with or without
5 .\" modification, are permitted provided that the following conditions
6 .\" are met:
7 .\" 1. Redistributions of source code must retain the above copyright
8 .\"    notice, this list of conditions and the following disclaimer.
9 .\" 2. Redistributions in binary form must reproduce the above copyright
10 .\"    notice, this list of conditions and the following disclaimer in the
11 .\"    documentation and/or other materials provided with the distribution.
12 .\"
13 .\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND
14 .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
15 .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
16 .\" ARE DISCLAIMED.  IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE
17 .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
18 .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
19 .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
20 .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
21 .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
22 .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
23 .\" SUCH DAMAGE.
24 .\"
25 .\" $FreeBSD$
26 .\"
27 .Dd December 24, 2008
28 .Dt POWERD 8
29 .Os
30 .Sh NAME
31 .Nm powerd
32 .Nd "system power control utility"
33 .Sh SYNOPSIS
34 .Nm
35 .Op Fl a Ar mode
36 .Op Fl b Ar mode
37 .Op Fl i Ar percent
38 .Op Fl n Ar mode
39 .Op Fl p Ar ival
40 .Op Fl P Ar pidfile
41 .Op Fl r Ar percent
42 .Op Fl v
43 .Sh DESCRIPTION
44 The
45 .Nm
46 utility monitors the system state and sets various power control options
47 accordingly.
48 It offers three modes (maximum, minimum, and adaptive) that can be
49 individually selected while on AC power or batteries.
50 The modes maximum, minimum, adaptive and hiadaptive may be abbreviated
51 max, min, adp, hadp.
52 .Pp
53 Maximum mode chooses the highest performance values.
54 Minimum mode selects the lowest performance values to get the most power
55 savings.
56 Adaptive mode attempts to strike a balance by degrading performance when
57 the system appears idle and increasing it when the system is busy.
58 It offers a good balance between a small performance loss for greatly
59 increased power savings.
60 Hiadaptive mode is alike adaptive mode, but tuned for systems where
61 performance and interactivity are more important then power consumption.
62 It rises frequency faster, drops slower and keeps twice lower CPU load.
63 The default mode is adaptive for battery power and hiadaptive for the rest.
64 .Pp
65 The
66 .Nm
67 utility recognizes the following runtime options:
68 .Bl -tag -width ".Fl r Ar percent"
69 .It Fl a Ar mode
70 Selects the
71 .Ar mode
72 to use while on AC power.
73 .It Fl b Ar mode
74 Selects the
75 .Ar mode
76 to use while on battery power.
77 .It Fl i Ar percent
78 Specifies the CPU load percent level when adaptive
79 mode should begin to degrade performance to save power.
80 The default is 50% or lower.
81 .It Fl n Ar mode
82 Selects the
83 .Ar mode
84 to use normally when the AC line state is unknown.
85 .It Fl p Ar ival
86 Specifies a different polling interval (in milliseconds) for AC line state
87 and system idle levels.
88 The default is 250 ms.
89 .It Fl P Ar pidfile
90 Specifies an alternative file in which the process ID should be stored.
91 The default is
92 .Pa /var/run/powerd.pid .
93 .It Fl r Ar percent
94 Specifies the CPU load percent level where adaptive
95 mode should consider the CPU running and increase performance.
96 The default is 75% or higher.
97 .It Fl v
98 Verbose mode.
99 Messages about power changes will be printed to stdout and
100 .Nm
101 will operate in the foreground.
102 .El
103 .Sh SEE ALSO
104 .Xr acpi 4 ,
105 .Xr apm 4 ,
106 .Xr cpufreq 4
107 .Sh HISTORY
108 The
109 .Nm
110 utility first appeared in
111 .Fx 6.0 .
112 .Sh AUTHORS
113 .An -nosplit
114 .An Colin Percival
115 first wrote
116 .Nm estctrl ,
117 the utility that
118 .Nm
119 is based on.
120 .An Nate Lawson
121 then updated it for
122 .Xr cpufreq 4 ,
123 added features, and wrote this manual page.
124 .Sh BUGS
125 The
126 .Nm
127 utility should also power down idle disks and other components besides the CPU.
128 .Pp
129 If
130 .Nm
131 is used with
132 .Pa power_profile ,
133 they may override each other.
134 .Pp
135 The
136 .Nm
137 utility
138 should probably use the
139 .Xr devctl 4
140 interface instead of polling for AC line state.